In the past decade, the introduction of molecularly targeted agents and immune-checkpoint inhibitors has led to improved survival outcomes for patients with advanced-stage lung cancer; however, this ...disease remains the leading cause of cancer-related mortality worldwide. Two large randomized controlled trials of low-dose CT (LDCT)-based lung cancer screening in high-risk populations - the US National Lung Screening Trial (NLST) and NELSON - have provided evidence of a statistically significant mortality reduction in patients. LDCT-based screening programmes for individuals at a high risk of lung cancer have already been implemented in the USA. Furthermore, implementation programmes are currently underway in the UK following the success of the UK Lung Cancer Screening (UKLS) trial, which included the Liverpool Health Lung Project, Manchester Lung Health Check, the Lung Screen Uptake Trial, the West London Lung Cancer Screening pilot and the Yorkshire Lung Screening trial. In this Review, we focus on the current evidence on LDCT-based lung cancer screening and discuss the clinical developments in high-risk populations worldwide; additionally, we address aspects such as cost-effectiveness. We present a framework to define the scope of future implementation research on lung cancer screening programmes referred to as Screening Planning and Implementation RAtionale for Lung cancer (SPIRAL).
European position statement on lung cancer screening Oudkerk, Matthijs; Devaraj, Anand; Vliegenthart, Rozemarijn ...
The lancet oncology,
December 2017, 2017-12-00, 20171201, Letnik:
18, Številka:
12
Journal Article
Recenzirano
Odprti dostop
Lung cancer screening with low-dose CT can save lives. This European Union (EU) position statement presents the available evidence and the major issues that need to be addressed to ensure the ...successful implementation of low-dose CT lung cancer screening in Europe. This statement identified specific actions required by the European lung cancer screening community to adopt before the implementation of low-dose CT lung cancer screening. This position statement recommends the following actions: a risk stratification approach should be used for future lung cancer low-dose CT programmes; that individuals who enter screening programmes should be provided with information on the benefits and harms of screening, and smoking cessation should be offered to all current smokers; that management of detected solid nodules should use semi-automatically measured volume and volume-doubling time; that national quality assurance boards should be set up to oversee technical standards; that a lung nodule management pathway should be established and incorporated into clinical practice with a tailored screening approach; that non-calcified baseline lung nodules greater than 300 mm3, and new lung nodules greater than 200 mm3, should be managed in multidisciplinary teams according to this EU position statement recommendations to ensure that patients receive the most appropriate treatment; and planning for implementation of low-dose CT screening should start throughout Europe as soon as possible. European countries need to set a timeline for implementing lung cancer screening.
Lung cancer causes more deaths than breast, cervical, and colorectal cancer combined. Nevertheless, population‐based lung cancer screening is still not considered standard practice in most countries ...worldwide. Early lung cancer detection leads to better survival outcomes: patients diagnosed with stage 1A lung cancer have a >75% 5‐year survival rate, compared to <5% at stage 4. Low‐dose computed tomography (LDCT) thorax imaging for the secondary prevention of lung cancer has been studied at length, and has been shown to significantly reduce lung cancer mortality in high‐risk populations. The US National Lung Screening Trial reported a 20% overall reduction in lung cancer mortality when comparing LDCT to chest X‐ray, and the Nederlands‐Leuvens Longkanker Screenings Onderzoek (NELSON) trial more recently reported a 24% reduction when comparing LDCT to no screening. Hence, the focus has now shifted to implementation research. Consequently, the 4‐IN‐THE‐LUNG‐RUN consortium based in five European countries, has set up a large‐scale multicenter implementation trial. Successful implementation of and accessibility to LDCT lung cancer screening are dependent on many factors, not limited to population selection, recruitment strategy, computed tomography screening frequency, lung‐nodule management, participant compliance, and cost effectiveness. This review provides an overview of current evidence for LDCT lung cancer screening, and draws attention to major factors that need to be addressed to successfully implement standardized, effective, and accessible screening throughout Europe. Evidence shows that through the appropriate use of risk‐prediction models and a more personalized approach to screening, efficacy could be improved. Furthermore, extending the screening interval for low‐risk individuals to reduce costs and associated harms is a possibility, and through the use of volumetric‐based measurement and follow‐up, false positive results can be greatly reduced. Finally, smoking cessation programs could be a valuable addition to screening programs and artificial intelligence could offer a solution to the added workload pressures radiologists are facing.
Pulmonary nodules are managed on the basis of their size and morphologic characteristics. Radiologists are familiar with assessing nodule size by measuring diameter using manually deployed electronic ...calipers. Size may also be assessed with 3D volumetric measurements (referred to as volumetry) obtained with software. Nodule size and growth are more accurately assessed with volumetry than on the basis of diameter, and the evidence supporting clinical use of volumetry has expanded, driven by its use in lung cancer screening nodule management algorithms in Europe. The application of volumetry has the potential to reduce recommendations for imaging follow-up of indeterminate solid nodules without impacting cancer detection. Although changes in scanning conditions and volumetry software packages can lead to variation in volumetry results, ongoing technical advances have improved the reliability of calculated volumes. Volumetry is now the primary method for determining size of solid nodules in the European lung cancer screening position statement and British Thoracic Society recommendations. The purposes of this article are to review technical aspects, advantages, and limitations of volumetry and, by considering specific scenarios, to contextualize the use of volumetry with respect to its importance in morphologic evaluation, its role in predicting malignancy in risk models, and its practical impact on nodule management. Implementation challenges and areas requiring further evidence are also highlighted.
Summary Background US guidelines now recommend lung cancer screening with low-dose CT for high-risk individuals. Reports of new nodules after baseline screening have been scarce and are inconsistent ...because of differences in definitions used. We aimed to identify the occurrence of new solid nodules and their probability of being lung cancer at incidence screening rounds in the Dutch-Belgian Randomized Lung Cancer Screening Trial (NELSON). Methods In the ongoing, multicentre, randomised controlled NELSON trial, between Dec 23, 2003, and July 6, 2006, 15 822 participants who had smoked at least 15 cigarettes a day for more than 25 years or ten cigarettes a day for more than 30 years and were current smokers, or had quit smoking less than 10 years ago, were enrolled and randomly assigned to receive either screening with low-dose CT (n=7915) or no screening (n=7907). From Jan 28, 2004, to Dec 18, 2006, 7557 individuals underwent baseline screening with low-dose CT; 7295 participants underwent second and third screening rounds. We included all participants with solid non-calcified nodules, registered by the NELSON radiologists as new or smaller than 15 mm3 (study detection limit) at previous screens. Nodule volume was generated semiautomatically by software. We calculated the maximum volume doubling time for nodules with an estimated percentage volume change of 25% or more, representing the minimum growth rate for the time since the previous scan. Lung cancer diagnosis was based on histology, and benignity was based on histology or stable size for at least 2 years. The NELSON trial is registered at trialregister.nl, number ISRCTN63545820. Findings We analysed data for participants with at least one solid non-calcified nodule at the second or third screening round. In the two incidence screening rounds, the NELSON radiologists registered 1222 new solid nodules in 787 (11%) participants. A new solid nodule was lung cancer in 49 (6%) participants with new solid nodules and, in total, 50 lung cancers were found, representing 4% of all new solid nodules. 34 (68%) lung cancers were diagnosed at stage I. Nodule volume had a high discriminatory power (area under the receiver operating curve 0·795 95% CI 0·728–0·862; p<0·0001). Nodules smaller than 27 mm3 had a low probability of lung cancer (two 0·5% of 417 nodules; lung cancer probability 0·5% 95% CI 0·0–1·9), nodules with a volume of 27 mm3 up to 206 mm3 had an intermediate probability (17 3·1% of 542 nodules; lung cancer probability 3·1% 1·9–5·0), and nodules of 206 mm3 or greater had a high probability (29 16·9% of 172 nodules; lung cancer probability 16·9% 12·0–23·2). A volume cutoff value of 27 mm3 or greater had more than 95% sensitivity for lung cancer. Interpretation Our study shows that new solid nodules are detected at each screening round in 5–7% of individuals who undergo screening for lung cancer with low-dose CT. These new nodules have a high probability of malignancy even at a small size. These findings should be considered in future screening guidelines, and new solid nodules should be followed up more aggressively than nodules detected at baseline screening. Funding Zorgonderzoek Nederland Medische Wetenschappen and Koningin Wilhelmina Fonds Kankerbestrijding.
Summary Background Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at ...screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Methods Eligible participants in the NELSON trial were those aged 50–75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl , number ISRCTN63545820. Findings 15 822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with median follow-up of 8·16 years (IQR 7·56–8·56). 187 (3%) of 7155 screened participants were diagnosed with 196 screen-detected lung cancers, and another 34 (<1%; 19 56% in the first year after screening, and 15 44% in the second year after screening) were diagnosed with 35 interval cancers. For the three screening rounds combined, with a 2-year follow-up, sensitivity was 84·6% (95% CI 79·6–89·2), specificity was 98·6% (95% CI 98·5–98·8), positive predictive value was 40·4% (95% CI 35·9–44·7), and negative predictive value was 99·8% (95% CI 99·8–99·9). Retrospective assessment of the last screening CT and clinical CT in 34 patients with interval cancer showed that interval cancers were not visible in 12 (35%) cases. In the remaining cases, cancers were visible when retrospectively assessed, but were not diagnosed because of radiological detection and interpretation errors (17 50%), misclassification by the protocol (two 6%), participant non-compliance (two 6%), and non-adherence to protocol (one 3%). Compared with screen-detected cancers, interval cancers were diagnosed at more advanced stages (29 83% of 35 interval cancers vs 44 22% of 196 screen-detected cancers diagnosed in stage III or IV; p<0·0001), were more often small-cell carcinomas (seven 20% vs eight 4%; p=0·003) and less often adenocarcinomas (nine 26% vs 102 52%; p=0·005). Interpretation Lung cancer screening in the NELSON trial yielded high specificity and sensitivity, with only a small number of interval cancers. The results of this study could be used to improve screening algorithms, and reduce the number of missed cancers. Funding Zorgonderzoek Nederland Medische Wetenschappen and Koningin Wilhelmina Fonds.
We studied 2240 indeterminate solid nodules (volume 50-500mm
) to determine the correlation of diameter and semi-automated volume measurements for pulmonary nodule size estimation. Intra-nodular ...diameter variation, defined as maximum minus minimum diameter through the nodule's center, varied by 2.8 mm (median, IQR:2.2-3.7 mm), so above the 1.5 mm cutoff for nodule growth used in Lung CT Screening Reporting and Data System (Lung-RADS). Using mean or maximum axial diameter to assess nodule volume led to a substantial mean overestimation of nodule volume of 47.2% and 85.1%, respectively, compared to semi-automated volume. Thus, size of indeterminate nodules is poorly represented by diameter.
Pre-results, ISRCTN63545820.
Predicted lung volumes based on the Global Lung Function Initiative (GLI) model are used in pulmonary disease detection and monitoring. It is unknown how well the predicted lung volume corresponds ...with computed tomography (CT) derived total lung volume (TLV). The aim of this study was to compare the GLI-2021 model predictions of total lung capacity (TLC) with CT-derived TLV. 151 female and 139 male healthy participants (age 45-65 years) were consecutively selected from a Dutch general population cohort, the Imaging in Lifelines (ImaLife) cohort. In ImaLife, all participants underwent low-dose, inspiratory chest CT. TLV was measured by an automated analysis, and compared to predicted TLC based on the GLI-2021 model. Bland-Altman analysis was performed for analysis of systematic bias and range between limits of agreement. To further mimic the GLI-cohort all analyses were repeated in a subset of never-smokers (51% of the cohort). Mean±SD of TLV was 4.7±0.9 L in women and 6.2±1.2 L in men. TLC overestimated TLV, with systematic bias of 1.0 L in women and 1.6 L in men. Range between limits of agreement was 3.2 L for women and 4.2 L for men, indicating high variability. Performing the analysis with never-smokers yielded similar results. In conclusion, in a healthy cohort, predicted TLC substantially overestimates CT-derived TLV, with low precision and accuracy. In a clinical context where an accurate or precise lung volume is required, measurement of lung volume should be considered.