Short-duration γ-ray bursts are intense flashes of cosmic γ-rays, lasting less than about two seconds, whose origin is unclear. The favoured hypothesis is that they are produced by a relativistic jet ...created by the merger of two compact stellar objects (specifically two neutron stars or a neutron star and a black hole). This is supported by indirect evidence such as the properties of their host galaxies, but unambiguous confirmation of the model is still lacking. Mergers of this kind are also expected to create significant quantities of neutron-rich radioactive species, whose decay should result in a faint transient, known as a 'kilonova', in the days following the burst. Indeed, it is speculated that this mechanism may be the predominant source of stable r-process elements in the Universe. Recent calculations suggest that much of the kilonova energy should appear in the near-infrared spectral range, because of the high optical opacity created by these heavy r-process elements. Here we report optical and near-infrared observations that provide strong evidence for such an event accompanying the short-duration γ-ray burst GRB 130603B. If this, the simplest interpretation of the data, is correct, then it confirms that compact-object mergers are the progenitors of short-duration γ-ray bursts and the sites of significant production of r-process elements. It also suggests that kilonovae offer an alternative, unbeamed electromagnetic signature of the most promising sources for direct detection of gravitational waves.
This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the ...possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and static gantry picket fence tests using an integrated electronic portal image. This software was used to monitor MLC daily performance over a 1 year period for two Varian TrueBeam linear accelerators, with the results directly compared with MLC positions determined using leaf trajectory log files. This software was validated by introducing known shifts and collimator errors. Skewness of the MLCs was found to be 0.03 ± 0.06° (mean ±1 standard deviation (SD)) and was dependent on whether the collimator was rotated manually or automatically. Trajectory log files, analysed using in-house software, showed average MLC positioning errors with a magnitude of 0.004 ± 0.003 mm (rotational) and 0.004 ± 0.011 mm (static) across two TrueBeam units over 1 year (mean ±1 SD). These ranges, as indicated by the SD, were lower than the related average MLC positioning errors of 0.000 ± 0.025 mm (rotational) and 0.000 ± 0.039 mm (static) that were obtained using the in-house EPID based software. The range of EPID measured MLC positional errors was larger due to the inherent uncertainties of the procedure. Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log files. This work shows the importance of increasing linac specific QC when phantom-less methodologies, such as the use of log files, are used to reduce patient specific QC. Tolerances of 0.25 mm have been created for the MLC positional errors using the EPID-based automated picket fence test. The software allows diagnosis of any specific leaf that needs repair and gives an indication as to the course of action that is required.
ON THE PROGENITORS OF GALACTIC NOVAE DARNLEY, M. J; RIBEIRO, V. A. R. M; BODE, M. F ...
The Astrophysical journal,
02/2012, Letnik:
746, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Of the approximately 400 known Galactic classical novae, only 10 of them, the recurrent novae, have been seen to erupt more than once. At least eight of these recurrents are known to harbor evolved ...secondary stars, rather than the main-sequence secondaries typical in classical novae. In this paper, we propose a new nova classification system, based solely on the evolutionary state of the secondary and not (like the current schemes) based on the properties of the outbursts. Using archival optical and near-infrared photometric observations of a sample of 38 quiescent Galactic novae we show that the evolutionary state of the secondary star in a quiescent system can be predicted and several objects are identified for follow-up observations: CI Aql, V2487 Oph, DI Lac, and EU Sct.
The recurrent nova M31N 2008-12a experiences annual eruptions, contains a near-Chandrasekhar-mass white dwarf, and has the largest mass accretion rate in any nova system. In this paper, we present ...Hubble Space Telescope (HST) WFC3/UVIS photometry of the late decline of the 2015 eruption. We couple these new data with archival HST observations of the quiescent system and Keck spectroscopy of the 2014 eruption. The late-time photometry reveals a rapid decline to a minimum luminosity state, before a possible recovery/rebrightening in the run up to the next eruption. Comparison with accretion disk models supports the survival of the accretion disk during the eruptions, and uncovers a quiescent disk mass accretion rate of the order of 10 − 6 M yr − 1 , which may rise beyond 10 − 5 M yr − 1 during the super-soft source phase-both of which could be problematic for a number of well-established nova eruption models. Such large accretion rates, close to the Eddington limit, might be expected to be accompanied by additional mass loss from the disk through a wind and even through collimated outflows. The archival HST observations, combined with the disk modeling, provide the first constraints on the mass donor: L donor = 103 − 11 + 12 L , R donor = 14.14 − 0.47 + 0.46 R , and T eff , donor = 4890 110 K, which may be consistent with an irradiated M31 red-clump star. Such a donor would require a system orbital period 5 days. Our updated analysis predicts that the M31N 2008-12a WD could reach the Chandrasekhar mass in < 20 kyr.
We report the results of a multi-year spectroscopic and photometric survey of novae in M31 that resulted in a total of 53 spectra of 48 individual nova candidates. Two of these, M31N 1995-11e and ...M31N 2007-11g, were revealed to be long-period Mira variables, not novae. These data double the number of spectra extant for novae in M31 through the end of 2009 and bring to 91 the number of M31 novae with known spectroscopic classifications. We find that 75 novae (82%) are confirmed or likely members of the Fe II spectroscopic class, with the remaining 16 novae (18%) belonging to the He/N (and related) classes. These numbers are consistent with those found for Galactic novae. We find no compelling evidence that spectroscopic class depends sensitively on spatial position or population within M31 (i.e., bulge versus disk), although the distribution for He/N systems appears slightly more extended than that for the Fe II class. We confirm the existence of a correlation between speed class and ejection velocity (based on line width), as in the case of Galactic novae. Follow-up photometry allowed us to determine light-curve parameters for a total of 47 of the 91 novae with known spectroscopic class. We confirm that more luminous novae generally fade the fastest and that He/N novae are typically faster and brighter than their Fe II counterparts. In addition, we find a weak dependence of nova speed class on position in M31, with the spatial distribution of the fastest novae being slightly more extended than that of slower novae.
The Challenge Facing Academic Radiotherapy Physics in the UK Hounsell, A.R.; Hawkins, M.A.; Evans, P.
Clinical oncology (Royal College of Radiologists (Great Britain)),
December 2019, 2019-12-00, 20191201, Letnik:
31, Številka:
12
Journal Article
Lung cancer's radiomic phenotype may potentially inform clinical decision-making with respect to radical radiotherapy. At present there are no validated biomarkers available for the individualisation ...of radical radiotherapy in lung cancer and the mortality rate of this disease remains the highest of all other solid tumours. MEDLINE was searched using the terms ‘radiomics’ and ‘lung cancer’ according to the Preferred Reporting Items for Systematic Reviews and Met-Analyses (PRISMA) guidance. Radiomics studies were defined as those manuscripts describing the extraction and analysis of at least 10 quantifiable imaging features. Only those studies assessing disease control, survival or toxicity outcomes for patients with lung cancer following radical radiotherapy ± chemotherapy were included. Study titles and abstracts were reviewed by two independent reviewers. The Radiomics Quality Score was applied to the full text of included papers. Of 244 returned results, 44 studies met the eligibility criteria for inclusion. End points frequently reported were local (17%), regional (17%) and distant control (31%), overall survival (79%) and pulmonary toxicity (4%). Imaging features strongly associated with clinical outcomes include texture features belonging to the subclasses Gray level run length matrix, Gray level co-occurrence matrix and kurtosis. The median cohort size for model development was 100 (15–645); in the 11 studies with external validation in a separate independent population, the median cohort size was 84 (21–295). The median number of imaging features extracted was 184 (10–6538). The median Radiomics Quality Score was 11% (0–47). Patient-reported outcomes were not incorporated within any studies identified. No studies externally validated a radiomics signature in a registered prospective study. Imaging-derived indices attained through radiomic analyses could equip thoracic oncologists with biomarkers for treatment response, patterns of failure, normal tissue toxicity and survival in lung cancer. Based on routine scans, their non-invasive nature and cost-effectiveness are major advantages over conventional pathological assessment. Improved tools are required for the appraisal of radiomics studies, as significant barriers to clinical implementation remain, such as standardisation of input scan data, quality of reporting and external validation of signatures in randomised, interventional clinical trials.
The Andromeda Galaxy recurrent nova M31N 2008-12a had been caught in eruption eight times. The inter-eruption period of M31N 2008-12a is ~1 yr, making it the most rapidly recurring system known, and ...a strong single-degenerate Type Ia supernova progenitor candidate. Following the 2013 eruption, a campaign was initiated to detect the predicted 2014 eruption and to then perform high cadence optical photometric and spectroscopic monitoring using ground-based telescopes, along with rapid UV and X-ray follow-up with the Swift satellite. Here we report the results of a high cadence multi-colour optical monitoring campaign, the spectroscopic evolution, and the UV photometry. We also discuss tantalising evidence of a potentially related, vastly-extended, nebulosity. The 2014 eruption was discovered, before optical maximum, on October 2, 2014. We find that the optical properties of M31N 2008-12a evolve faster than all Galactic recurrent novae known, and all its eruptions show remarkable similarity both photometrically and spectroscopically. Optical spectra were obtained as early as 0.26 days post maximum, and again confirm the nova nature of the eruption. A significant deceleration of the inferred ejecta expansion velocity is observed which may be caused by interaction of the ejecta with surrounding material,possibly a red giant wind. We find a low ejected mass and low ejection velocity, which are consistent with high mass-accretion rate, high mass white dwarf, and short recurrence time models of novae. We encourage additional observations, especially around the predicted time of the next eruption, towards the end of 2015.
This article presents an overview of the recent developments and requirements in radiotherapy dosimetry, with particular emphasis on the development of optical fibre dosemeters for radiotherapy ...applications, focusing particularly on in vivo applications. Optical fibres offer considerable advantages over conventional techniques for radiotherapy dosimetry, owing to their small size, immunity to electromagnetic interferences, and suitability for remote monitoring and multiplexing. The small dimensions of optical fibre-based dosemeters, together with being lightweight and flexible, mean that they are minimally invasive and thus particularly suited to in vivo dosimetry. This means that the sensor can be placed directly inside a patient, for example, for brachytherapy treatments, the optical fibres could be placed in the tumour itself or into nearby critical tissues requiring monitoring, via the same applicators or needles used for the treatment delivery thereby providing real-time dosimetric information. The article outlines the principal sensor design systems along with some of the main strengths and weaknesses associated with the development of these techniques. The successful demonstration of these sensors in a range of different clinical environments is also presented.
Cardiac disease is a dose-limiting toxicity in non-small cell lung cancer radiotherapy. The dose to the heart base has been associated with poor survival in multiple institutional and clinical trial ...datasets using unsupervised, voxel-based analysis. Validation has not been undertaken in a cohort with individual patient delineations of the cardiac base or for the endpoint of cardiac events. The purpose of this study was to assess the association of heart base radiation dose with overall survival and the risk of cardiac events with individual heart base contours.
Patients treated between 2015 and 2020 were reviewed for baseline patient, tumour and cardiac details and both cancer and cardiac outcomes as part of the NI-HEART study. Three cardiologists verified cardiac events including atrial fibrillation, heart failure and acute coronary syndrome. Cardiac substructure delineations were completed using a validated deep learning-based autosegmentation tool and a composite cardiac base structure was generated. Cox and Fine-Gray regressions were undertaken for the risk of death and cardiac events.
Of 478 eligible patients, most received 55 Gy/20 fractions (96%) without chemotherapy (58%), planned with intensity-modulated radiotherapy (71%). Pre-existing cardiovascular morbidity was common (78% two or more risk factors, 46% one or more established disease). The median follow-up was 21.1 months. Dichotomised at the median, a higher heart base Dmax was associated with poorer survival on Kaplan-Meier analysis (20.2 months versus 28.3 months; hazard ratio 1.40, 95% confidence interval 1.14-1.75, P = 0.0017) and statistical significance was retained in multivariate analyses. Furthermore, heart base Dmax was associated with pooled cardiac events in a multivariate analysis (hazard ratio 1.75, 95% confidence interval 1.03-2.97, P = 0.04).
Heart base Dmax was associated with the rate of death and cardiac events after adjusting for patient, tumour and cardiovascular factors in the NI-HEART study. This validates the findings from previous unsupervised analytical approaches. The heart base could be considered as a potential sub-organ at risk towards reducing radiation cardiotoxicity.