A magnetic solid phase extraction method coupled to capillary electrophoresis is proposed for the determination of tetracycline, oxytetracycline, chlortetracycline and doxycycline in milk samples. ...Five different magnetic phenyl silica adsorbents covered with magnetite were synthesized by varying the molar ratio of phenyltrimethylsilane and tetramethylorthosilicate; these adsorbents were evaluated in terms of their pH and degree of hydrophobicity for tetracycline retention. The optimal, selected combination of conditions was a pH of 10.0 and a magnetic sorbent ratio of 4:1; under these conditions, the retention capacity ranged from 99.7% to 101.2% for the four tetracyclines analyzed. The elution conditions and initial sample volume of the proposed extraction method were also optimized, and the best results were obtained with 1
×
10
−3
M acetic acid in methanol as eluent and a 200
ml of sample volume. Under optimal conditions, average recoveries ranged from 94.2% to 99.8% and the limits of detection ranged from 2 to 9
μg
l
−1 for the four tetracyclines. After the proposed method was optimized and validated, 25 milk samples of different brands were analyzed, oxytetracycline residues were detected in five samples, in concentrations ranging from 98 to 213
μg
l
−1. Subsequent analysis of positive samples by SPE–CE and magnetic solid phase extraction–HPLC revealed than no significant differences were found from results obtained by the proposed methodology. Thus, the developed magnetic extraction is a robust pre-concentration technique that can be coupled to other analytical methods for the quantitative determination of tetracyclines.
To achieve analytical success, it is necessary to develop thorough clean-up procedures to extract analytes from the matrix. Dispersive solid phase extraction (DSPE) has been used as a pretreatment ...technique for the analysis of several compounds. This technique is based on the dispersion of a solid sorbent in liquid samples in the extraction isolation and clean-up of different analytes from complex matrices. DSPE has found a wide range of applications in several fields, and it is considered to be a selective, robust, and versatile technique. The applications of dispersive techniques in the analysis of veterinary drugs in different matrices involve magnetic sorbents, molecularly imprinted polymers, carbon-based nanomaterials, and the Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method. Techniques based on DSPE permit minimization of additional steps such as precipitation, centrifugation, and filtration, which decreases the manipulation of the sample. In this review, we describe the main procedures used for synthesis, characterization, and application of this pretreatment technique and how it has been applied to food analysis.
•A magnetic solid phase extraction method based on Fe3O4–SiO2–phenyl was developed.•This technique is based on the dispersion of a magnetic adsorbent in liquid samples.•Method developed was employed ...for the extraction of nine sulphonamides from milk.•The novel method was validated according European Decision 2002/657/EC.•Method demonstrated to be an efficient strategy for sulphonamides determination.
A simple and effective method based on magnetic solid-phase extraction combined with high performance liquid chromatography was used for the determination of nine sulphonamides in milk samples. The extraction and cleanup via silica-based magnetic adsorbent dispersion in milk samples followed by the magnetic isolation and desorption of the analytes using NaOH–methanol. Three different magnetic phenyl silica adsorbents were synthesized by varying the molar ratio of phenyltrimethylsilane and tetramethylorthosilicate; these adsorbents were evaluated for sulphonamides retention in terms of their pH and degree of hydrophobicity. The optimal conditions were a pH of 6.0 and a magnetic:sorbent ratio of 2:1. Under optimal conditions, limits of detection ranging from 7 to 14μgL−1 were obtained. The method was validated according with the European Commision Decision 2002/657/EC. The proposed method was applied to analyse sulphonamides in 27 milk samples of different brands. Thirteen samples tested were positive for the presence of sulphonamides.
Expanded polystyrene (EPS) and polyurethane foams (PUFs) are widely produced and used due to their properties and, recently, it has been described that polystyrene present π-π interactions. ...Therefore, this work proposes to use recycled EPS to modify the surface of PUFs for the retention of 12 polycyclic aromatic hydrocarbons (PAHs) in air samples. PUF cylinders were modified with recycled polystyrene and characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, and affinity experiments. The proposed material is suitable for the retention-elution of PAHs from air samples, and can be incorporated to liquid chromatography generating a quantitative methodology. This methodology is efficient, fast and use lower volumes of organic solvents compared with other methodologies. Eighteen urban air samples were collected and analyzed weekly, using principal component analysis (PCA), and a relation between meteorological parameters and concentration of PAHs was observed.
In this work, a procedure using solid phase microextraction in combination with capillary electrophoresis was developed for the determination of oxytetracycline in milk samples. The method involves ...the synthesis of poly(1-allyl-3-methyl imidazolium) chloride film on a stainless-steel bar via electropolymerization and its use as an adsorbent for oxytetracycline (OT) by an ionic exchange mechanism. The coated fiber is then immersed in milk samples for retention of oxytetracycline residues, followed by elution, drying, and reconstitution before analysis with capillary electrophoresis. The proposed method achieves a limit of detection of 70 µg L
¹ with adequate precision and uncertainty, making this methodology appropriate for the determination of OT in milk samples. The method was applied to the pre-concentration and quantification of oxytetracycline in ten commercial milk samples. Two tested samples were positive for the presence of oxytetracycline but the concentration was below the maximum residue limit according to the international normative standard. The proposed methodology was evaluated according to the Eco-Scale approach, and the total score of 51 indicated that the methodology proposed is both green and acceptable despite the multi-stage character. SPME-CE methodology allows us to perform the sample pre-treatment and determination of OT in an effective and greener way, decreasing the number of steps during the analysis and the generation of waste.
A magnetic solid phase extraction technique followed by liquid chromatography with a fluorescence detector for naproxen analysis in human urine samples was developed. The method includes the ...extraction of naproxen with a magnetic solid synthetized with magnetite and poly 4-vinylpriridine, followed by the magnetic separation of the solid phase and desorption of the analyte with methanol. Under optimal conditions, the linear range of the calibration curve was 0.05-0.60 μg L
, with a limit of detection of 0.02 μg L
. In all cases values of repeatability were lower than 5.0% with recoveries of 99.4 ± 1.3%. Precision and accuracy values are adequate for naproxen (Npx) analysis in urine samples.
Solid-phase extraction in combination with large-volume sample stacking-capillary electrophoresis (SPE-LVSS-CE) was applied to measure chlortetracycline, doxycycline, oxytetracycline, and ...tetracycline in milk samples. Under optimal conditions, the proposed method had a linear range of 29 to 200 µg·L−1, with limits of detection ranging from 18.6 to 23.8 µg·L−1 with inter- and intraday repeatabilities < 10% (as a relative standard deviation) in all cases. The enrichment factors obtained were from 50.33 to 70.85 for all the TCs compared with a conventional capillary zone electrophoresis (CZE). This method is adequate to analyze tetracyclines below the most restrictive established maximum residue limits. The proposed method was employed in the analysis of 15 milk samples from different brands. Two of the tested samples were positive for the presence of oxytetracycline with concentrations of 95 and 126 µg·L−1. SPE-LVSS-CE is a robust, easy, and efficient strategy for online preconcentration of tetracycline residues in complex matrices.
Cellulose acetate is derived from cellulose and has the characteristics of biodegradability and reusability. So, it has been used for the elimination of toxic compounds capable of producing different ...diseases, such as cadmium, that result from human and industrial activity. For this reason, capsules functionalized with Cyanex 923 were prepared and characterized by FTIR spectroscopy, Energy Dispersive X-ray Spectroscopy (EDX), and SEM. The functionalized capsules were used for removing and recovering Cd(II) by modifying variables such as HCl concentration in the extraction medium and carrier content in the capsules, among others. The extraction of cadmium from battery leachates and the three isotherm models, Langmuir, Freundlich, and Dubinin Radushkevich, were also tested to model the cadmium removal process. The results showed a favorable physical sorption with a good capacity for extraction and the possibility of reusing the capsules for up to seven cycles without a decrease in the percentage of cadmium recovery.
Since lead is a highly toxic metal, it is necessary to detect its presence in different samples; unfortunately, analysis can be complicated if the samples contain concentrations below the detection ...limit of conventional analytical techniques. Solid phase extraction is a technique that allows the carrying out of a pre-concentration process and thus makes it easy to quantify analytes. This work studied the efficiency of sorption and preconcentration of lead utilizing polysulfone (PSf) fibers grafted with acrylic acid (AA). The best conditions for Pb(II) extraction were: pH 5, 0.1 mol L
of ionic strength, and 40 mg of sorbent (70% of removal). The sorbed Pb(II) was pre-concentrated by using an HNO
solution and quantified using flame atomic absorption spectrometry. The described procedure was used to obtain a correlation curve between initial concentrations and those obtained after the preconcentration process. This curve and the developed methodology were applied to the determination of Pb(II) concentration in a water sample contained in a handmade glazed clay vessel. With the implementation of the developed method, it was possible to pre-concentrate and determine a leached Pb(II) concentration of 258 µg L
.
Water polluted by discarded heavy metals such as lead is creating a global pollution problem. In this work, adsorption of Pb(II) was realized in batch studies by a hybrid membrane of cellulose ...acetate with ZnO particles. First, ZnO particles were prepared by precipitation and immobilized on the membrane. The hybrid membrane was elaborated by interfacial polymerization. The structure and surface were characterized based on Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and scanning electron microscopy (SEM). Batch experiments were carried out under different conditions where the number of particles of ZnO present in the membrane and the pH of the aqueous solution were varied. The Langmuir and Freundlich isotherm models were evaluated in the best adsorption conditions. Data fitted well with a Langmuir model with a maximum adsorption capacity of 15.55 mg·g
, which was similar for this type of materials. Thermodynamic parameters such as Gibbs free energy, enthalpy, and entropy showed that the process was spontaneous and favorable. The hybrid membrane was evaluated in simulated wastewater of the battery industry with a superior efficiency of up to 97%; without the medium, it did not generate interference. These results suggest that Pb(II) removal by hybrid membrane is possible.