Catheter ablation of ventricular tachycardia (VT) is effective and particularly useful in patients with frequent defibrillator interventions. Various substrate modification techniques have been ...described for unmappable or hemodynamically intolerable VT. Noninducibility is the most frequently used end point but is associated with significant limitations, so the optimal end point remains unclear. We hypothesized that elimination of local abnormal ventricular activities (LAVAs) during sinus rhythm or ventricular pacing would be a useful and effective end point for substrate-based VT ablation. As an adjunct to this strategy, we used a new high-density mapping catheter and frequently used epicardial mapping.
Seventy patients (age, 67±11 years; 7 female) with VT and structurally abnormal ventricle(s) were prospectively enrolled. Conventional mapping was performed in sinus rhythm in all, and a high-density Pentaray mapping catheter was used in the endocardium (n=35) and epicardially. LAVAs were recorded in 67 patients (95.7%; 95% confidence interval, 89.2-98.9). Catheter ablation was performed targeting LAVA with an irrigated-tip catheter placed endocardially via a transseptal or retrograde aortic approach or epicardially via the subxiphoid approach. LAVAs were successfully abolished or dissociated in 47 of 67 patients (70.1%; 95% confidence interval, 58.7-80.1). In multivariate analysis, LAVA elimination was independently associated with a reduction in recurrent VT or death (hazard ratio, 0.49; 95% confidence interval, 0.26-0.95; P=0.035) during long-term follow-up (median, 22 months).
LAVAs can be identified in most patients with scar-related VT. Elimination of LAVAs is feasible and safe and is associated with superior survival free from recurrent VT.
Mechanisms of Pulmonary Vein Reconnection After Radiofrequency Ablation of Atrial Fibrillation
Introduction
Pulmonary vein reconnection (PVR) is an important cause of AF recurrence after ablation. ...With the advent of force sensing catheters, catheter–tissue contact can be determined quantitatively. Since contact force (CF) plays a major role in determining the characteristics of RF lesion, we prospectively assessed the mechanisms of PVR with regard to catheter‐contact and lesion distances in patients undergoing AF ablation.
Methods and Results
Forty symptomatic AF patients underwent wide circumferential PV isolation (PVI) with SmartTouch™ CF catheter. The exact locations of acute PVI and spontaneous or adenosine‐provoked PVR were annotated on CARTO. One thousand nine hundred and twenty‐six RF lesions isolated 153 PVs. PVR occurred in 35 (23%) PVs: 22 (63%) adenosine‐provoked and 13 (37%) spontaneous. CF was significantly lower at PVR versus PVI sites for RF lesions within 6 mm from these sites: mean CF 5 versus 11 g (P < 0.0001) and force–time integral (FTI) 225 versus 415 gs (P < 0.0001); 86% of PVR occurred with a mean CF < 10 g (FTI < 400 gs); and the remaining 14% occurred at ablation sites with a long interlesion distance (≥5 mm) despite mean CF ≥ 10 g. Eighty percent of PVR sites were located anteriorly. There were no significant differences in regard to arrhythmia freedom between the patients without (69%) versus with PVR (67%; P = 1.0).
Conclusions
Acutely durable PVI can be achieved when RF lesions are delivered with a mean CF ≥ 10 g and an interlesion distance <5 mm. The majority of PVR occur anteriorly due to inadequate CF or long interlesion distances.
This study sought to evaluate the relationship between fibrosis imaged by delayed-enhancement (DE) magnetic resonance imaging (MRI) and atrial electrograms (Egms) in persistent atrial fibrillation ...(AF).
Atrial fractionated Egms are strongly related to slow anisotropic conduction. Their relationship to atrial fibrosis has not yet been investigated.
Atrial high-resolution MRI of 18 patients with persistent AF (11 long-lasting persistent AF) was registered with mapping geometry (NavX electro-anatomical system (version 8.0, St. Jude Medical, St. Paul, Minnesota)). DE areas were categorized as dense or patchy, depending on their DE content. Left atrial Egms during AF were acquired using a high-density, 20-pole catheter (514 ± 77 sites/map). Fractionation, organization/regularity, local mean cycle length (CL), and voltage were analyzed with regard to DE.
Patients with long-lasting persistent versus persistent AF had larger left atrial (LA) surface area (134 ± 38 cm(2) vs. 98 ± 9 cm(2), p = 0.02), a higher amount of atrial DE (70 ± 16 cm(2) vs. 49 ± 10 cm(2), p = 0.01), more complex fractionated atrial Egm (CFAE) extent (54 ± 16 cm(2) vs. 28 ± 15 cm(2), p = 0.02), and a shorter baseline AF CL (147 ± 10 ms vs. 182 ± 14 ms, p = 0.01). Continuous CFAE (CFEmean NavX algorithm that quantifies Egm fractionation <80 ms) occupied 38 ± 19% of total LA surface area. Dense DE was detected at the left posterior left atrium. In contrast, the right posterior left atrium contained predominantly patchy DE. Most CFAE (48 ± 14%) occurred at non-DE LA sites, followed by 41 ± 12% CFAE at patchy DE and 11 ± 6% at dense DE regions (p = 0.005 and p = 0.008, respectively); 19 ± 6% CFAE sites occurred at border zones of dense DE. Egms were less fractionated, with longer CL and lower voltage at dense DE versus non-DE regions: CFEmean: 97 ms versus 76 ms, p < 0.0001; local CL: 153 ms versus 143 ms, p < 0.0001; mean voltage: 0.63 mV versus 0.86 mV, p < 0.0001.
Atrial fibrosis as defined by DE MRI is associated with slower and more organized electrical activity but with lower voltage than healthy atrial areas. Ninety percent of continuous CFAE sites occur at non-DE and patchy DE LA sites. These findings are important when choosing the ablation strategy in persistent AF.
Complex-fractionated atrial electrograms and atrial fibrosis are associated with maintenance of persistent atrial fibrillation (AF). We hypothesized that pulmonary vein isolation (PVI) plus ablation ...of selective atrial low-voltage sites may be more successful than PVI only.
A total of 85 consecutive patients with persistent AF underwent high-density atrial voltage mapping, PVI, and ablation at low-voltage areas (LVA < 0.5 mV in AF) associated with electric activity lasting > 70% of AF cycle length on a single electrode (fractionated activity) or multiple electrodes around the circumferential mapping catheter (rotational activity) or discrete rapid local activity (group I). The procedural end point was AF termination. Arrhythmia freedom was compared with a control group (66 patients) undergoing PVI only (group II). PVI alone was performed in 23 of 85 (27%) patients of group I with low amount (< 10% of left atrial surface area) of atrial low voltage. Selective atrial ablation in addition to PVI was performed in 62 patients with termination of AF in 45 (73%) after 11 ± 9 minutes radiofrequency delivery. AF-termination sites colocalized within LVA in 80% and at border zones in 20%. Single-procedural arrhythmia freedom at 13 months median follow-up was achieved in 59 of 85 (69%) patients in group I, which was significantly higher than the matched control group (31/66 47%, P < 0.001). There was no significant difference in the success rate of patients in group I with a low amount of low voltage undergoing PVI only and patients requiring PVI+selective low-voltage ablation (P = 0.42).
Ablation of sites with distinct activation characteristics within/at borderzones of LVA in addition to PVI is more effective than conventional PVI-only strategy for persistent AF. PVI only seems to be sufficient to treat patients with left atrial low voltage < 10%.
Complex fractionated atrial electrograms (CFAE) are targets of atrial fibrillation (AF) ablation. Serial high-density maps were evaluated to understand the impact of activation direction and rate on ...electrogram (EGM) fractionation.
Eighteen patients (9 persistent) underwent high-density, 3-dimensional, left-atrial mapping (>400 points/map) during AF, sinus (SR), and CS-paced (CSp) rhythms. In SR and CSp, fractionation was defined as an EGM with ≥4 deflections, although, in AF, CFE-mean <80 ms was considered as continuous CFAE. The anatomic distribution of CFAE sites was assessed, quantified, and correlated between rhythms. Mechanisms underlying fractionation were investigated by analysis of voltage, activation, and propagation maps. A minority of continuous CFAE sites displayed EGM fractionation in SR (15+/-4%) and CSp (12+/-8%). EGM fractionation did not match between SR and CSp at 70+/-10% sites. Activation maps in SR and CSp showed that wave collision (71%) and regional slow conduction (24%) caused EGM fractionation. EGM voltage during AF (0.59+/-0.58 mV) was lower than during SR and CSp (>1.0 mV) at all sites. During AF, the EGM voltage was higher at continuous CFAE sites than at non-CFAE sites (0.53 mV (Q1, Q3: 0.33 to 0.83) versus 0.30 mV (Q1, Q3: 0.18 to 0.515), P<0.00001). Global LA voltage in AF was lower in patients with persistent AF versus patients with paroxysmal AF (0.6+/-0.59 mV versus 1.12+/-1.32 mV, P<0.01).
The distribution of fractionated EGMs is highly variable, depending on direction and rate of activation (SR versus CSp versus AF). Fractionation in SR and CSp rhythms mostly resulted from wave collision. All sites with continuous fractionation in AF displayed normal voltage in SR, suggesting absence of structural scar. Thus, many fractionated EGMs are functional in nature, and their sites dynamic.
Catheter ablation of persistent atrial fibrillation (AF) is associated with longer procedure times and lower long-term success rates than that of paroxysmal AF.
To test the hypothesis that ...restoration/maintenance of sinus rhythm (SR) preablation would facilitate AF termination and improve outcomes in patients with persistent AF.
We conducted a 2-group cohort study of consecutive patients with persistent AF and SR restored for at least 1 month prior to ablation (SR group; n = 40) and controls matched by age, sex, and AF duration (control group; n = 40). Radiofrequency stepwise catheter ablation was performed in AF for both groups (induced and spontaneous, respectively). Success was defined as freedom from atrial tachyarrhythmia without antiarrhythmic drugs beyond 1 year of follow-up.
During the index ablation procedure, AF cycle length was longer in the SR group than in the control group (183 ± 32 ms vs 166 ± 20 ms; P = .06), suggestive of reverse remodeling. In the SR group, AF more frequently terminated during ablation (95.0% vs 77.5%; P <.05) and required less extensive ablation of complex fractionated electrograms (40.0% vs 87.5%; P <.001) and linear lesions (42.5% vs 82.5%; P <.001). Mean procedural (199.8 ± 69.8 minutes vs 283.5 ± 72.3 minutes; P <.001), fluoroscopy (51.0 ± 24.9 minutes vs 96.3 ± 32.1 minutes; P <.001), and radiofrequency energy delivery (47.5 ± 18.9 minutes vs 97.0 ± 30.6 minutes; P <.001) times were shorter in the SR group. Clinical success rates were similar between groups for first (55.0% vs 45.0%; P = .28) and last (80.0% vs 70.0%; P = .28) procedures, during similar follow-up periods (21.1 ± 9.7 months).
Restoration of SR prior to catheter ablation for persistent AF whenever possible decreases the extent of ablation with the same high clinical efficacy.
This study prospectively evaluated the role of a novel 3-dimensional, noninvasive, beat-by-beat mapping system, Electrocardiographic Mapping (ECM), in facilitating the diagnosis of atrial ...tachycardias (AT).
Conventional 12-lead electrocardiogram, a widely used noninvasive tool in clinical arrhythmia practice, has diagnostic limitations.
Various AT (de novo and post-atrial fibrillation ablation) were mapped using ECM followed by standard-of-care electrophysiological mapping and ablation in 52 patients. The ECM consisted of recording body surface electrograms from a 252-electrode-vest placed on the torso combined with computed tomography-scan-based biatrial anatomy (CardioInsight Inc., Cleveland, Ohio). We evaluated the feasibility of this system in defining the mechanism of AT-macro-re-entrant (perimitral, cavotricuspid isthmus-dependent, and roof-dependent circuits) versus centrifugal (focal-source) activation-and the location of arrhythmia in centrifugal AT. The accuracy of the noninvasive diagnosis and detection of ablation targets was evaluated vis-à-vis subsequent invasive mapping and successful ablation.
Comparison between ECM and electrophysiological diagnosis could be accomplished in 48 patients (48 AT) but was not possible in 4 patients where the AT mechanism changed to another AT (n = 1), atrial fibrillation (n = 1), or sinus rhythm (n = 2) during the electrophysiological procedure. ECM correctly diagnosed AT mechanisms in 44 of 48 (92%) AT: macro-re-entry in 23 of 27; and focal-onset with centrifugal activation in 21 of 21. The region of interest for focal AT perfectly matched in 21 of 21 (100%) AT. The 2:1 ventricular conduction and low-amplitude P waves challenged the diagnosis of 4 of 27 macro-re-entrant (perimitral) AT that can be overcome by injecting atrioventricular node blockers and signal averaging, respectively.
This prospective multicenter series shows a high success rate of ECM in accurately diagnosing the mechanism of AT and the location of focal arrhythmia. Intraprocedural use of the system and its application to atrial fibrillation mapping is under way.
J waves are the hallmark of both inferolateral early repolarization (ER) and Brugada syndrome. While ajmaline, a class 1a antiarrhythmic drug, accentuates the J wave in Brugada syndrome, its effect ...on ER is unreported.
To describe the effect of ajmaline on the electrocardiogram in ER.
We analyzed electrocardiograms before and after the administration of intravenous ajmaline (1 mg/kg) in 31 patients with ER, 21 patients with Brugada type 1 electrocardiogram (Br), and 22 controls. ER was defined as J-point elevation of ≥1 mm with QRS slurring or notching in ≥2 inferolateral leads (I, aVL, II, III, aVF, V4-V6).
Ajmaline decreased mean J-wave amplitude in the ER group from 0.2 ± 0.15 mV at baseline to 0.08 ± 0.09 mV (P < .001). The QRS width prolonged significantly in all 3 groups, but the prolongation was significantly less in the ER group (+21 ms) than in the Br group (+36 ms; P < .001) or controls (+28 ms; P = .010). Decrease in mean inferolateral R-wave amplitude was similar in all the groups (ER group -0.14 mV; Br group -0.11 mV; controls -0.13 mV; P = ns), but mean inferolateral S-wave amplitude increased significantly less in the ER group (ER group +0.14 mV; Br group +16 mV; controls +0.20 mV; P < .001).
Ajmaline significantly decreases the J-wave amplitude in ER and prolongs the QRS width significantly less than in patients with Br. This indicates a different pathogenesis for both disorders. The altered terminal QRS vector probably is responsible for the decrease in the J-wave amplitude in ER, although a specific effect of ajmaline on J waves cannot be excluded.
The Octaray (Biosense Webster) is a novel, multispline mapping catheter with 48 closely spaced microelectrodes enabling high-resolution electroanatomical mapping.
This study sought to report the ...initial clinical mapping experience with this novel catheter in a variety of cardiac arrhythmias and to compare the mapping performance with the 5-spline Pentaray.
Fifty consecutive procedures among 46 patients were retrospectively analyzed regarding safety, efficacy, and acute procedural success defined as termination or noninducibility of clinical tachycardia, conduction block across an ablation line, or pulmonary vein isolation. In addition, another 10 patients with sustained atrial tachycardia mapped with the 5-spline catheter (2-5-2 spacing) or the novel 8-spline catheter (2-2-2-2-2 spacing) were analyzed.
Left atrial and ventricular mapping by either transseptal (n = 41) or retroaortic (n = 2) access was feasible without any complications related to the multispline design of the novel catheter. The acute procedural success rate was 94%. In sustained atrial tachycardia compared with the 5-spline catheter, the novel 8-spline catheter recorded more electrograms per map (3,628 ± 714 vs 11,350 ± 1,203; P < 0.001) in a shorter mapping time (13 ± 2 vs 9 ± 1 minutes; P = 0.08) resulting in a higher point density (18 ± 4 vs 59 ± 10 electrograms/cm
; P < 0.01) and point acquisition rate (308 ± 69 vs 1,332 ± 208 electrograms/min.; P < 0.01).
In this initial experience, mapping with the novel catheter was safe and efficient with a high electroanatomical resolution. In sustained atrial tachycardia the novel 8-spline catheter demonstrated a marked increase in point density and mapping speed compared with those of the 5-spline catheter. These initial results should be validated in a larger multicenter cohort with longer follow-up.
The number of pulmonary vein isolation (PVI) ablation procedures is steadily increasing worldwide resulting in a substantial radiation exposure to patients and operators. The aim of our study was to ...reduce radiation exposure during these procedures to a critical amount without compromising patient safety.
First, we assessed radiation exposure for primary PVI procedures over time (2005-2015) at the University Heart Center Freiburg-Bad Krozingen. Second, we prospectively evaluated in 52 patients, the efficacy and safety of a novel radiation reduction program (particularly applying an enhanced fluoroscopy pulse dose-reduction and optimized 3D-mapping system use). In 2035 primary PVI procedures, radiation exposure, assessed as estimated effective dose (eED in mSv, dose area product * 0.002 * conversion factor for females), fluoroscopy-time, and procedure-time decreased significantly from 2005 to 2015 (e.g. eED decreased from 9.3 (interquartile range (IQR) 6.4-13.4) mSv to 0.9 (IQR 0.5-1.6) mSv, p for trend <0.001). Importantly, application of the enhanced radiation reduction program further reduced eED to 0.4 mSv (IQR 0.3-0.6, P < 0.001 vs. control), a value not significantly different from slow-pathway ablation procedures (P = 0.41). Multiple linear regression analysis identified the radiation reduction program as the only independent variable associated with a decrease in radiation exposure.
Radiation exposure during PVI decreased over the last decade and can further be reduced significantly by the implementation of an enhanced radiation reduction program.