Proton beam therapy can potentially offer improved treatment for cancers of the head and neck and in paediatric patients. There has been a sharp uptake of proton beam therapy in recent years as ...improved delivery techniques and patient benefits are observed. However, treatments are currently planned using conventional x-ray CT images due to the absence of devices able to perform high quality proton computed tomography (pCT) under realistic clinical conditions. A new plastic-scintillator-based range telescope concept, named ASTRA, is proposed here to measure the proton's energy loss in a pCT system. Simulations conducted using GEANT4 yield an expected energy resolution of 0.7%. If calorimetric information is used the energy resolution could be further improved to about 0.5%. In addition, the ability of ASTRA to track multiple protons simultaneously is presented. Due to its fast components, ASTRA is expected to reach unprecedented data collection rates, similar to 10
protons/s. The performance of ASTRA has also been tested by simulating the imaging of phantoms. The results show excellent image contrast and relative stopping power reconstruction.
The second phase of the T2K experiment is expected to start data taking in autumn 2022. An upgrade of the Near Detector (ND280) is under development and includes the construction of two new Time ...Projection Chambers called High-Angle TPC (HA-TPC). The two endplates of these TPCs will be paved with eight Micromegas type charge readout modules. The Micromegas detector charge amplification structure uses a resistive anode to spread the charges over several pads to improve the space point resolution. This innovative technique is combined with the bulk-Micromegas technology to compose the “Encapsulated Resistive Anode Micromegas” detector. A prototype has been designed, built and exposed to an electron beam at the DESY II test beam facility.
The data have been used to characterize the charge spreading and to produce its map. Spatial resolution better than 600 μm and energy resolution better than 9% are obtained for all incident angles. These performances fulfil the requirements for the upgrade of the ND280 TPC.
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The ...two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, for a total of 32 ERAMs. This innovative technique allows the detection of the charge emitted by ionization electrons over several pads, improving the determination of the track position.
The TPC prototype has been equipped with the first ERAM module produced for T2K and with the HA-TPC readout electronics chain and it has been exposed to an electron beam at DESY in order to measure spatial and dE/dx resolution. In this paper we characterize the performances of the ERAM and, for the first time, we compare them with a newly developed simulation of the detector response.
Spatial resolution better than 800 μm and dE/dx resolution better than 10% are observed for all the incident angles and for all the drift distances of interest. All the main features of the data are correctly reproduced by the simulation and these performances fully fulfill the requirements for the HA-TPCs of T2K.
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with ...16 charge readout resistive Micromegas modules.
A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and reliable operation of the detectors once installed. A dedicated X-ray test bench is used to characterize the detectors by scanning each pad individually and to precisely measure the uniformity of the gain and the deposited energy resolution over the pad plane. An energy resolution of about 10% is obtained.
A detailed physical model has been developed to describe the charge dispersion phenomena in the resistive Micromegas anode. The detailed physical description includes initial ionization, electron drift, diffusion effects and the readout electronics effects. The model provides an excellent characterization of the charge spreading of the experimental measurements and allowed the simultaneous extraction of gain and charge spreading information of the modules.
The charge-conjugation and parity-reversal (CP) symmetry of fundamental particles is a symmetry between matter and antimatter. Violation of this CP symmetry was first observed in 1964
, and CP ...violation in the weak interactions of quarks was soon established
. Sakharov proposed
that CP violation is necessary to explain the observed imbalance of matter and antimatter abundance in the Universe. However, CP violation in quarks is too small to support this explanation. So far, CP violation has not been observed in non-quark elementary particle systems. It has been shown that CP violation in leptons could generate the matter-antimatter disparity through a process called leptogenesis
. Leptonic mixing, which appears in the standard model's charged current interactions
, provides a potential source of CP violation through a complex phase δ
, which is required by some theoretical models of leptogenesis
. This CP violation can be measured in muon neutrino to electron neutrino oscillations and the corresponding antineutrino oscillations, which are experimentally accessible using accelerator-produced beams as established by the Tokai-to-Kamioka (T2K) and NOvA experiments
. Until now, the value of δ
has not been substantially constrained by neutrino oscillation experiments. Here we report a measurement using long-baseline neutrino and antineutrino oscillations observed by the T2K experiment that shows a large increase in the neutrino oscillation probability, excluding values of δ
that result in a large increase in the observed antineutrino oscillation probability at three standard deviations (3σ). The 3σ confidence interval for δ
, which is cyclic and repeats every 2π, is -3.41, -0.03 for the so-called normal mass ordering and -2.54, -0.32 for the inverted mass ordering. Our results indicate CP violation in leptons and our method enables sensitive searches for matter-antimatter asymmetry in neutrino oscillations using accelerator-produced neutrino beams. Future measurements with larger datasets will test whether leptonic CP violation is larger than the CP violation in quarks.
The T2K experiment reports updated measurements of neutrino and antineutrino oscillations using both appearance and disappearance channels. This result comes from an exposure of 14.9 (16.4) × 1020 ...protons on target in neutrino (antineutrino) mode. Significant improvements have been made to the neutrino interaction model and far detector reconstruction. An extensive set of simulated data studies have also been performed to quantify the effect interaction model uncertainties have on the T2K oscillation parameter sensitivity. T2K performs multiple oscillation analyses that present both frequentist and Bayesian intervals for the Pontecorvo-Maki-Nakagawa-Sakata parameters. For fits including a constraint on sin 2θ13 from reactor data and assuming normal mass ordering T2K measures sin 2θ23 = 0.53 +0.03 −0.04 and Δm232 = (2.45 ± 0.07) × 10−3 eV2 c−4. The Bayesian analyses show a weak preference for normal mass ordering (89% posterior probability) and the upper sin 2θ23 octant (80% posterior probability), with a uniform prior probability assumed in both cases. The T2K data exclude CP conservation in neutrino oscillations at the 2σ level.