Transverse and longitudinal polarization of
Λ
hyperons has been studied. The transfere of polarization from high-energy positron to
Λ
0
hyperon has been measured. The longitudinal spin transverse ...coefficient is found to be
D
L
L
′
Λ
=
0
.
1
1
±
0
.
1
0
(
s
t
a
t
)
±
0
.
0
3
(
s
y
s
)
. The transverse polarization of
Λ
and
Λ
̄
hyperons has been measured in inclusive quasireal photoproduction process for various target nuclei. The polarization observed is positive for light target nuclei and compartaible with zero for heavy target nuclei.
An estimate is given of the simulation with the Monte Carlo (MC) method using the signal to background ratios in invariant mass spectra of pion-kaon system for decays of
D
0
→
K
−
π
+
and
→
K
+
π
−
...originated from decays of
D
*
+
→
D
0
π
+
and
D*
−
→
π
−
at different momentum/angular bins of pions (when pion is coming to the ARICH acceptance) and kaons (kaon is in ARICH acceptance). The tabulated data for mentioned ratios will be used by Belle II collaboration to study the ARICH performance. Then the results of ARICH efficiencies and misidentification probability extracted based on tabulated ratios, will become important ingredient for future physics analysis.
We report the first measurement of the average of the electron-proton and positron-proton elastic scattering cross sections. This lepton charge-averaged cross section is insensitive to the leading ...effects of hard two-photon exchange, giving more robust access to the proton's electromagnetic form factors. The cross section was extracted from data taken by the OLYMPUS experiment at DESY, in which alternating stored electron and positron beams were scattered from a windowless gaseous hydrogen target. Elastic scattering events were identified from the coincident detection of the scattered lepton and recoil proton in a large-acceptance toroidal spectrometer. The luminosity was determined from the rates of Møller, Bhabha, and elastic scattering in forward electromagnetic calorimeters. The data provide some selectivity between existing form factor global fits and will provide valuable constraints to future fits.
Slow control of the Belle II Aerogel Ring Imaging detector Pestotnik, R.; Adachi, I.; Adamczyk, K. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/2023, Letnik:
1056
Journal Article
Recenzirano
Odprti dostop
Since 2018, an Proximity Focusing Aerogel Ring Imaging Detector (ARICH) efficiently separates hadrons in the forward end-cap of the Belle II spectrometer. Cherenkov photons emitted in the ...double-layer aerogel radiator are expanded in 16-cm space and detected on the photon detector, which consists of 420 hybrid avalanche photodiodes and rear readout electronics operating in threshold mode. Each of the sensors requires six different high voltages and a supply of four low voltages for the electronics. Because of the power dissipation, the system also includes a cooling system in which cold water circulates through the Al tubes thermally connected to the readout electronics. Reliable control of supply voltages and monitoring of environmental data and sensor status ensure stable operation of the ARICH detector and early response to sudden changes in current, single event disturbances, overheating, and other faults. In this paper, we introduce the ARICH’s slow control system and the data quality monitor used to track performance.
In the forward end-cap of the Belle II spectrometer, particle identification is provided by a proximity focusing RICH detector with an aerogel radiator (ARICH). The ARICH’s primary function is to ...effectively distinguish between pions and kaons in the momentum range of 0.5GeV/c to about 4GeV/c, as well as to contribute to identification of low-momentum leptons. Since its operation began, Belle II has collected over 420fb−1 of data. Based on this large data sample, studies of several effects that impact the performance of the ARICH detector were carried out. In this paper, we present a comparison of the observed Cherenkov ring image and detector particle identification performance in the measured data and detector simulation. Furthermore, we highlight recent efforts aimed at enhancing the ARICH’s performance by taking into account the effects of particle decay in flight and scattering in materials before the detector, as well as by refining the probability density function used for particle identification likelihood evaluation.
A measurement of beam-helicity asymmetries for single-hadron production in deep-inelastic scattering is presented. Data from the scattering of 27.6 GeV electrons and positrons off gaseous hydrogen ...and deuterium targets were collected by the HERMES experiment. The asymmetries are presented separately as a function of the Bjorken scaling variable, the hadron transverse momentum, and the fractional energy for charged pions and kaons as well as for protons and anti-protons. These asymmetries are also presented as a function of the three aforementioned kinematic variables simultaneously.
The verification scheme in the package “Professor2” for setting parameters of the most used physics generator PYTHIA8.2 for simulating the processes in high energy physics is described. The goal is ...to tune the PYTHIA8.2 parameter list for the fragmentation process below
the production threshold. As an initial parameter list, we use the Belle (predecessor of the Belle II experiment) default parameter settings for fragmentation. For the MC pseudo-data, we use the Belle II software package i.e. basf2, and generator script developed by the main author of this paper. To validate the whole procedure, we use momentum distribution of charged pions and kaons to tune two free parameters of the fragmentation model in PYTHIA8 i.e. LUND fragmentation model. We demonstrate that the Professor2 package is a handful to perform multi-parameter tunes simultaneously.
The OLYMPUS experiment Milner, R.; Hasell, D.K.; Kohl, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2014, Letnik:
741
Journal Article
Recenzirano
Odprti dostop
The OLYMPUS experiment was designed to measure the ratio between the positron–proton and electron–proton elastic scattering cross-sections, with the goal of determining the contribution of two-photon ...exchange to the elastic cross-section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, μpGEp/GMp, made using polarization techniques and those made in unpolarized experiments. OLYMPUS operated on the DORIS storage ring at DESY, alternating between 2.01GeV electron and positron beams incident on an internal hydrogen gas target. The experiment used a toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight detectors to measure rates for elastic scattering over the polar angular range of approximately 25°–75°. Symmetric Møller/Bhabha calorimeters at 1.29° and telescopes of GEM and MWPC detectors at 12° served as luminosity monitors. A total luminosity of approximately 4.5fb−1 was collected over two running periods in 2012. This paper provides details on the accelerator, target, detectors, and operation of the experiment.
Abstract
The Aerogel Ring Imaging Cherenkov (ARICH) counter serves as a particle identification device in the forward end-cap region of the Belle II spectrometer. It is capable of identifying pions ...and kaons with momenta up to $4\>$GeV$\>$c$^{-1}$ by detecting Cherenkov photons emitted in the silica aerogel radiator. After the detector alignment and calibration of the probability density function, we evaluate the performance of the ARICH counter using early beam collision data. Event samples of $D^{\ast +} \to D^0 \pi^+ (D^0 \to K^-\pi^+)$ were used to determine the $\pi(K)$ efficiency and the $K(\pi)$ misidentification probability. We found that the ARICH counter is capable of separating kaons from pions with an identification efficiency of $93.5 \pm 0.6 \, \%$ at a pion misidentification probability of $10.9 \pm 0.9 \, \%$. This paper describes the identification method of the counter and the evaluation of the performance during its early operation.