Background Remote manipulation of wireless capsule endoscopes might improve diagnostic accuracy and facilitate therapy. Objective To test a new capsule-manipulation system. Setting University ...hospital. Design and Interventions A first-in-human study tested a new magnetic maneuverable wireless capsule in a volunteer. A wireless capsule endoscope was modified to include neodymium-iron-boron magnets. The capsule's magnetic switch was replaced with a thermal one and turned on by placing it in hot water. One imager was removed from the PillCam colon-based capsule, and the available space was used to house the magnets. A handheld external magnet was used to manipulate this capsule in the esophagus and stomach. The capsule was initiated by placing it in a mug of hot water. The capsule was swallowed and observed in the esophagus and stomach by using a gastroscope. Capsule images were viewed on a real-time viewer. Main Outcome Measurements The capsule was manipulated in the esophagus for 10 minutes. It was easy to make the capsule turn somersaults and to angulate at the cardioesophageal junction. In the stomach, it was easy to move the capsule back from the pylorus to the cardioesophageal junction and hold/spin the capsule at any position in the stomach. The capsule in the esophagus and stomach did not cause discomfort. Limitations Magnetic force varies with the fourth power of distance. Conclusions This study suggests that remote manipulation of a capsule in the esophagus and stomach of a human is feasible and might enhance diagnostic endoscopy as well as enable therapeutic wireless capsule endoscopy.
Endoscopic balloon dilatation and laparoscopic myotomy are established treatments for achalasia. Recently, a new endoscopic technique for complete myotomy was described. Herein, we report the results ...of the first prospective trial of peroral endoscopic myotomy (POEM) in Europe.
POEM was performed under general anesthesia in 16 patients (male:female (12:4), mean age 45 years, range 26-76). The primary outcome was symptom relief at 3 months, defined as an Eckhard score ≤3. Secondary outcomes were procedure-related adverse events, lower esophageal sphincter (LES) pressure on manometry, reflux symptoms, and medication use before and after POEM.
A 3-month follow-up was completed for all patients. Treatment success (Eckhard score ≤3) was achieved in 94% of cases (mean score pre- vs. post-treatment (8.8 vs. 1.4); P<0.001). Mean LES pressure was 27.2 mm Hg pre-treatment and 11.8 mm Hg post-treatment (P<0.001). No patient developed symptoms of gastro-esophageal reflux after treatment, but one patient was found to have an erosive lesion (LA grade A) on follow-up esophagogastroduodenoscopy. No patient required medication with proton pump inhibitors or antacids after POEM.
POEM is a promising new treatment for achalasia resulting in short-term symptom relief in >90% of cases. Studies evaluating long-term efficacy and comparing POEM with established treatments have been initiated.
Background Remote control of capsule endoscopes might allow reliable inspection of the human stomach. Objective To assess the safety and efficacy of manipulation of a modified capsule endoscope with ...magnetic material (magnetic maneuverable capsule MMC) in the human stomach by using a handheld external magnet. Design Open clinical trial. Setting Academic hospital. Patients Ten healthy volunteers. Interventions Subjects swallowed the MMC and sherbet powder for gastric distention. An external magnetic paddle (EMP-2) was used to manipulate the MMC within the stomach. MMC responsiveness was evaluated on a screen showing the MMC film in real time. Main Outcome Measurements Safety and tolerability (questionnaire), gastric residence time of the MMC, its responsiveness to the EMP-2, area of gastric mucosa visualized. Results There were no adverse events. The MMC was always clearly attracted by the EMP-2 and responded to its movements. It remained in the stomach for 39 ± 24 minutes. In 7 subjects, both the cardia and the pylorus were inspected and 75% or more of the gastric mucosa was visualized (≥50% in all of the remaining subjects). A learning curve was clearly recognizable (identification of MMC localization, intended movements). Limitations Small amounts of fluid blocked the view of apical parts of the fundus; gastric distention was not sufficient to flatten all gastric folds. Conclusions Remote control of the MMC in the stomach of healthy volunteers using a handheld magnet is safe and feasible. Responsiveness of the MMC was excellent, and visualization of the gastric mucosa was good, although not yet complete, in the majority of subjects. The system appeared to be clinically valuable and should be developed further. (Clinical trial registration number: DE/CA05/2009031008.)
Symptoms related to abnormal gastrointestinal motility and function are common. Oropharyngeal and oesophageal dysphagia, heartburn, bloating, abdominal pain and alterations in bowel habits are among ...the most frequent reasons for seeking medical attention from internists or general practitioners and are also common reasons for referral to gastroenterologists and colorectal surgeons. However, the nonspecific nature of gastrointestinal symptoms, the absence of a definitive diagnosis on routine investigations (such as endoscopy, radiology or blood tests) and the lack of specific treatments make disease management challenging. Advances in technology have driven progress in the understanding of many of these conditions. This Review serves as an introduction to a series of Consensus Statements on the clinical measurements of gastrointestinal motility, function and sensitivity. A structured, evidence-based approach to the initial assessment and empirical treatment of patients presenting with gastrointestinal symptoms is discussed, followed by an outline of the contribution of modern physiological measurement on the management of patients in whom the cause of symptoms has not been identified with other tests. Discussions include the indications for and utility of high-resolution manometry, ambulatory pH-impedance monitoring, gastric emptying studies, breath tests and investigations of anorectal structure and function in day-to-day practice and clinical management.
We performed a systematic review and meta-analyses to estimate treatment efficacy and constipation rate of 5-hydroxytryptamine (serotonin) (5-HT(3)) antagonists in patients with nonconstipated (NC) ...or diarrhea-predominant (D)-irritable bowel syndrome (IBS).
Two reviewers independently searched MEDLINE, EMBASE, and Web of Science (January 1, 1966 to December 15, 2006) for randomized controlled trials of 5-HT(3) antagonists in IBS reporting clinical end points of the IBS symptom complex and safety parameters. Study characteristics, markers of methodologic quality, and outcomes for the intention-to-treat population for each randomized controlled trial were extracted independently.
We found 14 eligible randomized controlled trials of alosetron (n = 3024) or cilansetron (n = 1116) versus placebo (n = 3043) or mebeverine (n = 304). Random-effects meta-analyses found 5-HT(3) antagonists more effective than the comparators in achieving global improvement in IBS symptoms (pooled relative risk, 1.60; 95% confidence interval CI, 1.49-1.72; I(2) = 0%) and relief of abdominal pain and discomfort (pooled relative risk, 1.30; 95% CI, 1.22-1.39; I(2) = 22%). Benefit was apparent for both agents, in patients of either sex. These agents were more likely to cause constipation (pooled relative risk, 4.28; 95% CI, 3.28-5.60, I(2) = 65%); there was less constipation with 5-HT(3) antagonists in D-IBS patients than in mixed populations (NC-IBS and D-IBS; relative risk ratio, 0.65; 95% CI, 0.41-0.99). Nine patients (0.2%) using 5-HT(3) antagonists had possible ischemic colitis versus none in control groups.
5-HT(3) antagonists significantly improve symptoms of NC-IBS or D-IBS in men and women. There is an increased risk of constipation with 5-HT(3) antagonists, although the risk is lower in those with D-IBS.
Esophageal motor disorders are an important cause of dysphagia but can also be associated with retrosternal pain and heartburn as well as regurgitation. In extreme cases, patients are not able to eat ...appropriately and lose weight. Repetitive aspiration can occur and may cause pulmonological complications. Achalasia represents the most important and best-defined esophageal motor disorder and is characterized by insufficient relaxation of the lower esophageal sphincter in combination with typical disturbances of esophageal peristalsis. Additional defined motor disorders are distal esophageal spasm, hypercontractile esophagus, absent contractility and ineffective peristalsis. Patients with appropriate symptoms should primarily undergo esophagogastroduodenoscopy for exclusion of e.g., tumors and esophagitis. Esophageal high-resolution manometry is the reference method for diagnosis and characterization of motor disorders in non-obstructive dysphagia. An esophagogram with barium swallow may deliver complementary information or may be used if manometry is not available. Balloon dilatation and Heller myotomy are long established and more or less equally effective therapeutic options for patients with achalasia. Peroral endoscopic myotomy (POEM) enhances the therapeutic armamentarium for achalasia and hypertensive/spastic motor disorders since 2010. For hypotensive motor disorders, which may occur as a complication of e.g., rheumatological diseases or idiopathically, therapeutic options are still limited.
Background Remote control of esophageal capsule endoscopes could enhance diagnostic accuracy. Objective To assess the safety and efficacy of remote magnetic manipulation of a modified capsule ...endoscope (magnetic maneuverable capsule MMC; Given Imaging Ltd, Yoqneam, Israel) in the esophagus of healthy humans. Design Randomized, controlled trial. Setting Academic hospital. Patients This study involved 10 healthy volunteers. Intervention All participants swallowed a conventional capsule (ESO2; Given Imaging) and a capsule endoscope with magnetic material, the MMC, which is activated by a thermal switch, in random order (1 week apart). An external magnetic paddle (EMP; Given Imaging) was used to manipulate the MMC within the esophageal lumen. MMC responsiveness was evaluated on a screen showing the MMC film in real time. Main Outcome Measurements Safety and tolerability of the procedure (questionnaire), responsiveness of the MMC to the EMP, esophageal transit time, and visualization of the Z-line. Results No adverse events occurred apart from mild retrosternal pressure (n = 5). The ability to rotate the MMC around its longitudinal axis and to tilt it by defined movements of the EMP was clearly demonstrated in 9 volunteers. Esophageal transit time was highly variable for both capsules (MMC, 111-1514 seconds; ESO2, 47-1474 seconds), but the MMC stayed longer in the esophagus in 8 participants ( P < .01). Visualization of the Z-line was more efficient with the ESO2 (inspection of 73% ± 18% of the circumference vs 33% ± 27%, P = .01). Limitations Magnetic forces were not strong enough to hold the MMC against peristalsis when the capsule approached the gastroesophageal junction. Conclusion Remote control of the MMC in the esophagus of healthy volunteers is safe and feasible, but higher magnetic forces may be needed. (Clinical trial registration number: DE/CA05/2009031008 .)
Background
Gastric emptying (GE) is delayed in a subset of patients with inflammatory bowel disease (IBD). We have shown before that altered release of gastrointestinal hormones may contribute to GE ...disturbances, but overall effects of disease activity remain unclear. Thus, we aimed to evaluate GE in patients with IBD during active disease and following therapy.
Design
A total of 20 healthy subjects (HC) and 26 patients with IBD hospitalized because of an acute episode of their disease (Crohn's disease (CD) n = 13, ulcerative colitis (UC) n = 13) underwent a standardized 13C‐octanoic acid GE breath test (baseline test). Plasma glucose, cholecystokinin (CCK), peptide YY (PYY) and glucagon‐like peptide‐1 (GLP‐1) were measured periodically throughout the test. A total of 16 patients underwent a second GE test after 3–4 months of therapy.
Results
At baseline, nine patients with IBD had pathologically delayed GE half‐time (T½ > 150 min) (P = 0·028 vs. HC). Moreover, T½ was significantly longer in the total group of patients with IBD than in HC (129 ± 12 min vs. 96 ± 7, P = 0·030). Postprandial GLP‐1 responses were elevated in IBD (P = 0·002 vs. HC) and correlated with T½ (P = 0·05). Following therapy clinical activity indices and T½ were decreased in IBD (P ≤ 0·01 vs. baseline), and T½ no longer differed from HC (P > 0·5). Moreover, GLP‐1 plasma levels decreased significantly (P = 0·031).
Conclusions
Higher disease activity in IBD is associated with prolonged GE and increased release of GLP‐1. Following effective therapy, GE is accelerated and GLP‐1 release decreases significantly. Thus, increased release of GLP‐1 from the inflamed mucosa might contribute to GE disturbances in IBD.
Polyneuropathy is a common complication to diabetes. Neuropathies within the enteric nervous system are associated with gastroenteropathy and marked symptoms that severely reduce quality of life. ...Symptoms are pleomorphic but include nausea, vomiting, dysphagia, dyspepsia, pain, bloating, diarrhoea, constipation and faecal incontinence. The aims of this review are fourfold. First, to provide a summary of the pathophysiology underlying diabetic gastroenteropathy. Secondly to give an overview of the diagnostic methods. Thirdly, to provide clinicians with a focussed overview of current and future methods for pharmacological and nonpharmacological treatment modalities. Pharmacological management is categorised according to symptoms arising from the upper or lower gut as well as sensory dysfunctions. Dietary management is central to improvement of symptoms and is discussed in detail, and neuromodulatory treatment modalities and other emerging management strategies for diabetic gastroenteropathy are discussed. Finally, we propose a diagnostic/investigation algorithm that can be used to support multidisciplinary management.