Recently, rapid phenotypic antimicrobial susceptibility testing (AST) based on microscopic imaging analysis has been developed. The aim of this study was to determine whether implementation of ...antimicrobial stewardship programmes (ASP) based on rapid phenotypic AST can increase the proportion of patients with haematological malignancies who receive optimal targeted antibiotics during early periods of bacteraemia.
This randomized controlled trial enrolled patients with haematological malignancies and at least one positive blood culture. Patients were randomly assigned 1:1 to conventional (n = 60) or rapid phenotypic (n = 56) AST. The primary outcome was the proportion of patients receiving optimal targeted antibiotics 72 hr after blood collection for culture.
The percentage receiving optimal targeted antibiotics at 72 hr was significantly higher in the rapid phenotypic AST group (45/56, 80.4%) than in conventional AST group (34/60, 56.7%) (relative risk (RR) 1.42, 95% confidence interval (CI) 1.09–1.83). The percentage receiving unnecessary broad-spectrum antibiotics at 72 hr was significantly lower (7/26, 12.5% vs 18/60, 30.0%; RR 0.42, 95% CI 0.19–0.92) and the mean time to optimal targeted antibiotic treatment was significantly shorter (38.1, standard deviation (SD) 38.2 vs 72.8, SD 93.0 hr; p < 0.001) in the rapid phenotypic AST group. The mean time from blood collection to the AST result was significantly shorter in the rapid phenotypic AST group (48.3, SD 17.6 vs 83.1, SD 22.2 hr).
ASP based on rapid phenotypic AST can rapidly optimize antibiotic treatment for bacteraemia in patients with haematological malignancy. Rapid phenotypic AST can improve antimicrobial stewardship in immunocompromised patients.
The Korea Invisible Mass Search (KIMS) collaboration has developed low-background NaI(Tl) crystals that are suitable for the direct detection of WIMP dark matter. Building on experience accumulated ...during the KIMS-CsI programs, the KIMS-NaI experiment will consist of a 200 kg NaI(Tl) crystal array surrounded by layers of shielding structures and will be operated at the Yangyang underground laboratory. The goal is to provide an unambiguous test of the DAMA/LIBRA annual modulation signature. Measurements of six prototype crystals show progress in the reduction of internal contamination from radioisotopes. Based on our understanding of these measurements, we expect to achieve a background level in the final detector configuration that is less than 1 count/day/keV/kg for recoil energies around 2 keV. The annual modulation sensitivity for the KIMS-NaI experiment shows that an unambiguous 7
σ
test of the DAMA/LIBRA signature would be possible with a 600 kg year exposure with this system.
The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals ...we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2–6) keV energy interval. The dominant contributors in this energy region are found to be
210
Pb and
3
H.
The RENO experiment has analyzed about 500 live days of data to observe an energy dependent disappearance of reactor νover ¯_{e} by comparing their prompt signal spectra measured in two identical ...near and far detectors. In the period between August of 2011 and January of 2013, the far (near) detector observed 31 541 (290 775) electron antineutrino candidate events with a background fraction of 4.9% (2.8%). The measured prompt spectra show an excess of reactor νover ¯_{e} around 5 MeV relative to the prediction from a most commonly used model. A clear energy and baseline dependent disappearance of reactor νover ¯_{e} is observed in the deficit of the observed number of νover ¯_{e}. Based on the measured far-to-near ratio of prompt spectra, we obtain sin^{2}2θ_{13}=0.082±0.009(stat)±0.006(syst) and |Δm_{ee}^{2}|=2.62_{-0.23}^{+0.21}(stat)_{-0.13}^{+0.12}(syst)×10^{-3} eV^{2}.
The annual modulation signal observed by the DAMA experiment is a long-standing question in the community of dark matter direct detection. This necessitates an independent verification of its ...existence using the same detection technique. The COSINE-100 experiment has been operating with 106 kg of low-background NaI(Tl) detectors providing interesting checks on the DAMA signal. However, due to higher backgrounds in the NaI(Tl) crystals used in COSINE-100 relative to those used for DAMA, it was difficult to reach final conclusions. Since the start of COSINE-100 data taking in 2016, we also have initiated a program to develop ultra-pure NaI(Tl) crystals for COSINE-200, the next phase of the experiment. The program includes efforts of raw powder purification, ultra-pure NaI(Tl) crystal growth, and detector assembly techniques. After extensive research and development of NaI(Tl) crystal growth, we have successfully grown a few small-size (0.61–0.78 kg) thallium-doped crystals with high radio-purity. A high light yield has been achieved by improvements of our detector assembly technique. Here we report the ultra-pure NaI(Tl) detector developments at the Institute for Basic Science, Korea. The technique developed here will be applied to the production of NaI(Tl) detectors for the COSINE-200 experiment.
Neutrino elastic scattering observation with NaI (NEON) is an experiment designed to detect neutrino-nucleus coherent scattering using reactor electron antineutrinos. NEON is based on an array of six ...NaI(Tl) crystals with a total mass of 13.3 kg, located at the tendon gallery that is 23.7 m away from a reactor core with a thermal power of 2.8 GW in the Hanbit nuclear power complex. The installation of the NEON detector was completed in December 2020, and since May 2021, the detector has acquired data at full reactor power. Based on the observed light yields of the NaI crystals of approximately 22, number of photoelectrons per unit keV electron-equivalent energy (keVee), and 6 counts/kg/keV/day background level at 2–6 keVee energy, coherent elastic neutrino-nucleus scattering (CE
ν
NS) observation sensitivity is evaluated as more than 3
σ
assuming 1-year reactor-on and 100 days reactor-off data, 0.2 keVee energy threshold, and 7 counts/keV/kg/day background in the signal region of 0.2
-
0.5 keVee. This paper describes the design of the NEON detector, including the shielding arrangement, configuration of NaI(Tl) crystals, and associated operating systems. The initial performance and associated sensitivity of the experiment are also presented.
The recent manufacturing trend toward mass customization and further personalization of products requires factories to be smarter than ever before in order to: (1) quickly respond to customer ...requirements, (2) resiliently retool machinery and adjust operational parameters for unforeseen system failures and product quality problems, and (3) retrofit old systems with upcoming new technologies. Furthermore, product lifecycles are becoming shorter due to unbounded and unpredictable customer requirements, thereby requiring reconfigurable and versatile manufacturing systems that underpin the basic building blocks of smart factories. This study introduces a modular factory testbed, emphasizing transformability and modularity under a distributed shop-floor control architecture. The main technologies and methods, being developed and verified through the testbed, are presented from the four aspects of rapid factory transformation: self-layout recognition, rapid workstation and robot reprogramming, inter-layer information sharing, and configurable software for shop-floor monitoring.
The aim of the Korean Imatinib Discontinuation Study was to identify predictors for safe and successful imatinib discontinuation. A total of 90 patients with a follow-up of ≥12 months were analyzed. ...After a median follow-up of 26.6 months after imatinib discontinuation, 37 patients lost the major molecular response. The probability of sustained major molecular response at 12 months and 24 months was 62.2% and 58.5%, respectively. All 37 patients who lost major molecular response were retreated with imatinib therapy for a median of 16.9 months, and all achieved major molecular response again at a median of 3.9 months after resuming imatinib therapy. We observed newly developed or worsened musculoskeletal pain and pruritus in 27 (30%) patients after imatinib discontinuation. Imatinib withdrawal syndrome was associated with a higher probability of sustained major molecular response (P=0.003) and showed a trend for a longer time to major molecular response loss (P=0.098). Positivity (defined as ≥ 17 positive chambers) of digital polymerase chain reaction at screening and longer imatinib duration before imatinib discontinuation were associated with a higher probability of sustained major molecular response. Our data demonstrated that the occurrence of imatinib withdrawal syndrome after imatinib discontinuation and longer duration of imatinib were associated with a lower rate of molecular relapse. In addition, minimal residual leukemia measured by digital polymerase chain reaction had a trend for a higher molecular relapse. (Trial registered at ClinicalTrials.gov: NCT01564836).
The advanced molybdenum-based rare process experiment (AMoRE) aims to search for neutrinoless double beta decay (
0
ν
β
β
) of
100
Mo with
∼
100
kg
of
100
Mo-enriched molybdenum embedded in cryogenic ...detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from
48
Ca-depleted calcium and
100
Mo-enriched molybdenum (
48
depl
Ca
100
MoO
4
). The simultaneous detection of heat (phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot
0
ν
β
β
search with a 111 kg day live exposure of
48
depl
Ca
100
MoO
4
crystals. No evidence for
0
ν
β
β
decay of
100
Mo is found, and a upper limit is set for the half-life of
0
ν
β
β
of
100
Mo of
T
1
/
2
0
ν
>
9.5
×
10
22
years
at 90% C.L. This limit corresponds to an effective Majorana neutrino mass limit in the range
⟨
m
β
β
⟩
≤
(
1.2
-
2.1
)
eV
.
Summary
Background
Little is known about factors affecting the quality of life (QoL) of patients with vitiligo, and previous studies have shown conflicting results.
Objectives
To explore the QoL of ...patients with vitiligo and to identify factors affecting QoL.
Methods
A nationwide questionnaire‐based study was conducted with 1123 patients with vitiligo recruited from 21 hospitals in Korea from July 2015 to June 2016. Data were collected using a structured questionnaire for demographic information and the Skindex‐29 instrument. Mild or severely impaired QoL in patients with vitiligo was assessed according to each domain (symptoms, functioning and emotions) of Skindex‐29. Multivariate logistic regression analyses were performed to determine the factors associated with QoL.
Results
Of the enrolled participants, 609 were male and 514 female, with a mean age of 49·8 years (range 20–84). The median duration of disease was 3·0 years (range 0–60). Using multivariate logistic regression modelling, the involvement of visible body parts and a larger affected body surface area were consistently associated with QoL impairment in all three domains of Skindex‐29. Additionally, the QoL of patients aged 20–59 years, who potentially had a more active social life than older patients, was associated with functional impairment. Furthermore, a higher educational background was associated with emotional impairment.
Conclusions
A multitude of factors significantly influence the QoL of patients with vitiligo. A better appreciation of these factors would help the management of these patients.
What's already known about this topic?
Quality of life is highly impaired in patients with vitiligo.
What does this study add?
The involvement of visible body parts and a larger affected body surface area were consistently associated with impaired symptoms, functioning and emotions.
Vitiligo with nonvisible lesions also considerably compromises quality of life; vitiligo should not be regarded as a cosmetic problem.
Patients aged 20–59 years experienced significant functional impairment, and those with a higher educational background had more impairment in their emotions.
Linked Comment: Ezzedine and Eleftheriadou. Br J Dermatol 2018; 178:28–29.
Plain language summary available online
Respond to this article