Summary Background Intracoronary administration of an abciximab bolus during a primary percutaneous coronary intervention results in a high local drug concentration, improved perfusion, and reduction ...of infarct size compared with intravenous bolus application. However, the safety and efficacy of intracoronary versus standard intravenous bolus application in patients with ST-elevation myocardial infarction (STEMI) undergoing this intervention has not been tested in a large-scale clinical trial. Methods The AIDA STEMI trial was a randomised, open-label, multicentre trial. Patients presenting with STEMI in the previous 12 h with no contraindications for abciximab were randomly assigned in a 1:1 ratio by a central web-based randomisation system to intracoronary versus intravenous abciximab bolus (0·25 mg/kg bodyweight) during percutaneous coronary intervention with a subsequent 12 h intravenous infusion 0·125 μg/kg per min (maximum 10 μg/min). The primary endpoint was a composite of all-cause mortality, recurrent infarction, or new congestive heart failure within 90 days of randomisation. Secondary endpoints were the time to occurrence of the primary endpoint, each individual component of that endpoint, early ST-segment resolution, thrombolysis in myocardial infarction (TIMI) flow grade, and enzymatic infarct size. A masked central committee adjudicated the primary outcome and its components. Treatment allocation was not concealed from patients and investigators. This trial is registered with ClinicalTrials.gov , NCT00712101. Findings Between July, 2008, and April, 2011, 2065 patients were randomly assigned intracoronary abciximab (n=1032) or intravenous abciximab (n=1033). Intracoronary, as compared with intravenous abciximab, resulted in a similar rate of the primary composite clinical endpoint at 90 days in 1876 analysable patients (7·0% vs 7·6%; odds ratio OR 0·91; 95% CI 0·64–1·28; p=0·58). The incidence of death (4·5% vs 3·6%; 1·24; 0·78–1·97; p=0·36) and reinfarction (1·8% vs 1·8%; 1·0; 0·51–1·96; p=0·99) did not differ between the treatment groups, whereas less patients in the intracoronary group had new congestive heart failure (2·4% vs 4·1%; 0·57; 0·33–0·97; p=0·04). None of the secondary endpoints or safety measures differed significantly between groups. Interpretation In patients with STEMI undergoing primary percutaneous coronary intervention, intracoronary as compared to intravenous abciximab did not result in a difference in the combined endpoint of death, reinfarction, or congestive heart failure. Since intracoronary abciximab bolus administration is safe and might be related to reduced rates of congestive heart failure the intracoronary route might be preferred if abciximab is indicated. Funding Lilly, Germany. University of Leipzig—Heart Centre. University of Leipzig, Clinical Trial Centre Leipzig, supported by the Federal Ministry of Education and Research (BMBF).
Background Intravenous abciximab reduces major adverse cardiac events in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). ...Intracoronary abciximab bolus application during PCI results in high local drug concentration, improved perfusion, reduction of infarct size, and less microvascular obstruction. The hypothesis of this trial is that abciximab bolus intracoronary in comparison to standard intravenous application will improve the outcome of patients undergoing primary PCI in STEMI. Study design The Abciximab Intracoronary versus intravenously Drug Application in STEMI (AIDA STEMI) study is a 1,912-patient, prospective, multicenter, randomized, open-label, controlled trial. The study is designed to compare the efficacy and safety of intracoronary versus intravenous bolus abciximab administration during primary PCI with subsequent intravenous infusion for 12 hours. Patients will be randomized in a 1:1 fashion to 1 of the 2 treatments. The primary efficacy end point of AIDA STEMI is the composite of all-cause mortality, recurrent MI, or new congestive heart failure within 90 days of randomization. The primary safety outcome assessment will be major bleeding. Conclusions The AIDA STEMI study addresses important questions regarding the efficacy and safety of intracoronary abciximab bolus administration during primary PCI in patients with STEMI, potentially optimizing the route of administration of glycoprotein IIb/IIIa inhibitors in the catheterization laboratory.
...the magnitude of the short-lived local effect of intracoronary abciximab might not be enough to produce changes in clinically meaningful endpoints, especially in the era of routine preloading with ...other potent antiplatelet agents. ...AIDA STEMI does not support a possible clinical superiority of intracoronary bolus delivery.
Objectives The objective of the study was to assess noninferiority of the polymer-free sirolimus-eluting Yukon Choice stent (Translumina GmbH, Hechingen, Germany) compared with the polymer-based ...Taxus Liberté stent (Boston Scientific, Natick, Massachusetts) with regard to the primary endpoint, in-stent late lumen loss, at 9 months in patients with diabetes mellitus. Background The Yukon Choice stent has been evaluated in several randomized controlled trials before, albeit to date, there has been no trial that exclusively enrolled patients with diabetes mellitus. Methods Patients with diabetes mellitus undergoing percutaneous coronary intervention for clinically significant de novo coronary artery stenosis were randomized 1:1 to receive either the polymer-free sirolimus-eluting Yukon Choice stent or the polymer-based paclitaxel-eluting Taxus Liberté stent. Results A total of 240 patients were randomized. Quantitative coronary angiography was available for 79% of patients. Mean in-stent late lumen loss was 0.63 ± 0.62 mm for the Yukon Choice stent and 0.45 ± 0.60 mm for the Taxus Liberté stent. Based on the pre-specified margin, the Yukon Choice stent failed to show noninferiority for the primary endpoint. During follow-up, there were no significant differences between groups regarding death, myocardial infarction, stent thrombosis, target lesion revascularization, target vessel revascularization, or nontarget vessel revascularization. Conclusions Compared with the Taxus Liberté stent, the polymer-free sirolimus-eluting Yukon Choice stent failed to show noninferiority with regard to the primary endpoint, in-stent late lumen loss, in patients with diabetes mellitus after 9-month follow-up. Both stents showed comparable clinical efficacy and safety. (Yukon Choice Versus Taxus Liberté in Diabetes Mellitus; NCT00368953 )