We report the properties of primary cosmic-ray sulfur (S) in the rigidity range 2.15 GV to 3.0 TV based on 0.38×10^{6} sulfur nuclei collected by the Alpha Magnetic Spectrometer experiment (AMS). We ...observed that above 90 GV the rigidity dependence of the S flux is identical to the rigidity dependence of Ne-Mg-Si fluxes, which is different from the rigidity dependence of the He-C-O-Fe fluxes. We found that, similar to N, Na, and Al cosmic rays, over the entire rigidity range, the traditional primary cosmic rays S, Ne, Mg, and C all have sizeable secondary components, and the S, Ne, and Mg fluxes are well described by the weighted sum of the primary silicon flux and the secondary fluorine flux, and the C flux is well described by the weighted sum of the primary oxygen flux and the secondary boron flux. The primary and secondary contributions of the traditional primary cosmic-ray fluxes of C, Ne, Mg, and S (even Z elements) are distinctly different from the primary and secondary contributions of the N, Na, and Al (odd Z elements) fluxes. The abundance ratio at the source for S/Si is 0.167±0.006, for Ne/Si is 0.833±0.025, for Mg/Si is 0.994±0.029, and for C/O is 0.836±0.025. These values are determined independent of cosmic-ray propagation.
Charge determination of nuclei with the AMS-02 silicon tracker Alpat, B.; Ambrosi, G.; Azzarello, Ph ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2005, Letnik:
540, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The silicon tracker of the AMS-02 detector measures the trajectory in three dimensions of electrons, protons and nuclei to high precision in a dipole magnetic field and thus measures their rigidity ...(momentum over charge) and the sign of their charge. In addition, it measures the specific energy loss of charged particles to determine the charge magnitude. Ladders from the AMS-02 tracker have been exposed to ion beams at CERN and GSI to study their response to nuclei from helium up to the iron group. The longest ladder,
72
×
496
mm
2
, verified in the tests contains 12 sensors. Good charge resolution is observed up to iron.
We present the precision measurements of 11 years of daily cosmic electron fluxes in the rigidity interval from 1.00 to 41.9 GV based on 2.0×10^{8} electrons collected with the Alpha Magnetic ...Spectrometer (AMS) aboard the International Space Station. The electron fluxes exhibit variations on multiple timescales. Recurrent electron flux variations with periods of 27 days, 13.5 days, and 9 days are observed. We find that the electron fluxes show distinctly different time variations from the proton fluxes. Remarkably, a hysteresis between the electron flux and the proton flux is observed with a significance of greater than 6σ at rigidities below 8.5 GV. Furthermore, significant structures in the electron-proton hysteresis are observed corresponding to sharp structures in both fluxes. This continuous daily electron data provide unique input to the understanding of the charge sign dependence of cosmic rays over an 11-year solar cycle.
Precision measurements by the Alpha Magnetic Spectrometer (AMS) on the International Space Station of the deuteron ( D ) flux are presented. The measurements are based on 21 × 10 6 D nuclei in the ...rigidity range from 1.9 to 21 GV collected from May 2011 to April 2021. We observe that over the entire rigidity range the D flux exhibits nearly identical time variations with the p , He 3 , and He 4 fluxes. Above 4.5 GV, the D / He 4 flux ratio is time independent and its rigidity dependence is well described by a single power law ∝ R Δ with Δ D / He 4 = − 0.108 ± 0.005 . This is in contrast with the He 3 / He 4 flux ratio for which we find Δ He 3 / He 4 = − 0.289 ± 0.003 . Above ∼ 13 GV we find a nearly identical rigidity dependence of the D and p fluxes with a D / p flux ratio of 0.027 ± 0.001 . These unexpected observations indicate that cosmic deuterons have a sizable primarylike component. With a method independent of cosmic ray propagation, we obtain the primary component of the D flux equal to 9.4 ± 0.5 % of the He 4 flux and the secondary component of the D flux equal to 58 ± 5 % of the He 3 flux. Published by the American Physical Society 2024
The AMS-02 TRD for the international space station Hauler, F.; Bartoloni, A.; Becker, U. ...
IEEE transactions on nuclear science,
2004-Aug., 2004-08-00, 20040801, Letnik:
51, Številka:
4
Journal Article
Recenzirano
The Alpha Magnetic Spectrometer (AMS-02) is an experiment which will be mounted on the international space station (ISS) to measure primary cosmic ray spectra in space. A key element is the ...transition radiation detector (TRD) to extract an e/sup +/ or p/sup -/ signal reducing the p/sup +/ or e/sup -/ background by a rejection factor 10/sup 2/--10/sup 3/ in an energy range from 10 to 300 GeV. This will be used in combination with an electromagnetic calorimeter to provide overall p/sup +/ rejection of 10/sup 6/ at 90% e/sup +/ efficiency. The detector consists of 20 layers of 6 mm diameter straw tubes alternating with 20 mm layers of polyethylene/polypropylene fleece radiator. The tubes are filled with a 4:1 mixture of Xe:CO/sub 2/ at 1 bar absolute pressure from a recirculating gas system designed to operate >3 years in space. There are in total 5248 straw tubes which are read out by a custom-made DAQ system in less than 80 /spl mu/s. The electronics must be low in power consumption and sustain the stringent requirements of operation in space. The construction of the detector and its electronics is presented in this paper.
We present the precision measurements of 11 years of daily cosmic positron fluxes in the rigidity range from 1.00 to 41.9 GV based on 3.4×10^{6} positrons collected with the Alpha Magnetic ...Spectrometer (AMS) aboard the International Space Station. The positron fluxes show distinctly different time variations from the electron fluxes at short and long timescales. A hysteresis between the electron fluxes and the positron fluxes is observed with a significance greater than 5σ at rigidities below 8.5 GV. On the contrary, the positron fluxes and the proton fluxes show similar time variation. Remarkably, we found that positron fluxes are modulated more than proton fluxes with a significance greater than 5σ for rigidities below 7 GV. These continuous daily positron fluxes, together with AMS daily electron, proton, and helium fluxes over an 11-year solar cycle, provide unique input to the understanding of both the charge-sign and mass dependencies of cosmic rays in the heliosphere.
This study describes the successful upgrade of a mechanically pumped CO2 two-phase cooling system in space by designing a new pump module for the Alpha Magnetic Spectrometer-02 on the International ...Space Station. Key factors for mission success are emphasized, including achieving high coolant filling accuracy within 10% of the target and maintaining system stability within ±1 °C. The impact of adding radiators to improve cooling efficiency is examined, and it is found that operating multi-radiators out-of-phase does not significantly affect system reliability. The centrifugal pump design is shown to allow for better lubricant circulation, while the in-house designed controller incorporates protective measures to prevent cavitation, overheating, and over-current. This research advances the understanding of circulation loop systems and their upgrades in space and demonstrates the potential for extending the lifetime of space-borne mechanically pumped two-phase cooling systems.
•First in-space upgrade of a pumped two-phase cooling system.•Quantitative on-orbit fluid transfer achieves 7% accuracy.•Superior system control stability of 1 °C with multiple out-f-phase radiators.•Prolonged mechanical pump lifetime via hardware and software manners.
The forward muon detector of L3 Adam, A.; Aguilar-Benitez, M.; Alarcon, J. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/1996, Letnik:
383, Številka:
2
Journal Article
Recenzirano
Odprti dostop
The forward-backward muon detector of the L3 experiment is presented. Intended to be used for LEP 200 physics, it consists of 96 self-calibrating drift chambers of a new design enclosing the magnet ...pole pieces of the L3 solenoid. The pole pieces are toroidally magnetized to form two independent analyzing spectrometers. A novel trigger is provided by resistive plate counters attached to the drift chambers. Details about the design, construction and performance of the whole system are given together with results obtained during the 1995 running at LEP.