A two-phase emission detector containing 5 kg of liquid Xe is installed at the horizontal experimental channel of the research nuclear reactor IRT MEPhI to measure the liquid Xe response to nuclei ...recoils with kinetic energies below 1 keV. Preliminary tests have demonstrated that ≥ 15 μs electron lifetime in liquid Xe and ~ 10 photoelectrons single ionization electron signal are achieved. These parameters are sufficient to detect and identify events at the single electron level.
We present that the next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double- β (0νββ) decay in 136Xe with a target half-life sensitivity of ...approximately 1028 yr using 5 × 103 kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the 136Xe mass, the monolithic and homogeneous configuration of the active medium, and the multiparameter measurements of the interactions enabled by the time projection chamber. Finally, the detector concept and anticipated performance are presented based upon demonstrated realizable background rates.
Many extensions of the standard model of particle physics suggest that neutrinos should be Majorana-type fermions-that is, that neutrinos are their own anti-particles-but this assumption is difficult ...to confirm. Observation of neutrinoless double-β decay (0νββ), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with (76)Ge (the GERDA experiment) and (136)Xe (the KamLAND-Zen and EXO (Enriched Xenon Observatory)-200 experiments) have established the lifetime of this decay to be longer than 10(25) years, corresponding to a limit on the neutrino mass of 0.2-0.4 electronvolts. Here we report new results from EXO-200 based on a large (136)Xe exposure that represents an almost fourfold increase from our earlier published data sets. We have improved the detector resolution and revised the data analysis. The half-life sensitivity we obtain is 1.9 × 10(25) years, an improvement by a factor of 2.7 on previous EXO-200 results. We find no statistically significant evidence for 0νββ decay and set a half-life limit of 1.1 × 10(25) years at the 90 per cent confidence level. The high sensitivity holds promise for further running of the EXO-200 detector and future 0νββ decay searches with an improved Xe-based experiment, nEXO.
Measurement of the sup.217Po half-life with the DEVIS track setup at the Institute of Theoretical and Experimental Physics (ITEP, Moscow) by means of a procedure based on determining lifetimes of ...individual nuclei is described. The value obtained for the sup.214Po half-life is 163.8 + or - 3.0 µs. The possibility of reaching the accuracy of the measurements that is required for testing the statement that the decay of some nuclei has a nonexponential character and the source intensity necessary for this are discussed.
Measurement of the
214
Po half-life with the DEVIS track setup at the Institute of Theoretical and Experimental Physics (ITEP, Moscow) by means of a procedure based on determining lifetimes of ...individual nuclei is described. The value obtained for the
214
Po half-life is 163.8 ± 3.0 µs. The possibility of reaching the accuracy of the measurements that is required for testing the statement that the decay of some nuclei has a nonexponential character and the source intensity necessary for this are discussed.