To reassess the definition of a large macular hole, factors predicting hole closure and post-surgery visual recovery.
Database study of 1483 primary macular hole operations. Eligible operations were ...primary MH operations treated with a vitrectomy and a gas or air tamponade. Excluded were eyes with a history of retinal detachment, high myopia, previous vitrectomy or trauma.
A higher proportion of operations were performed in eyes from females (71.1%) who were 'on average' younger (p < 0.001), with slightly larger holes (p < 0.001) than male patients. Sulfur hexafluoride gas was generally used for smaller holes (p < 0.001). From 1253 operations with a known surgical outcome, successful hole closure was achieved in 1199 (96%) and influenced by smaller holes and complete ILM peeling (p < 0.001), but not post-surgery positioning (p = 0.072). A minimum linear diameter of ~500 μm marked the threshold where the success rate started to decline. From the 1056 successfully closed operations eligible for visual outcome analysis, visual success (defined as visual acuity of 0.30 or better logMAR) was achieved in 488 (46.2%) eyes. At the multivariate level, the factors predicting visual success were better pre-operative VA, smaller hole size, shorter duration of symptoms and the absence of AMD.
Females undergoing primary macular hole surgery tend to be younger and have larger holes than male patients. The definition of a large hole should be changed to around 500 μm, and patients should be operated on early to help achieve a good post-operative VA.
Data on the outcome of surgery facilitate informed preoperative patient counselling. Most studies on the outcome of surgery for idiopathic full thickness macular hole surgery have concentrated on ...rates of anatomical closure. The aim of this study was to identify factors predicting visual success (better than 20/40; 6/12 Snellen) following macular hole surgery.
A retrospective study of 133 patients undergoing standardised macular hole surgery with at least 3 months of postoperative follow-up. All patients underwent preoperative measurement of the maximum macular hole diameter using optical coherence tomography.
Multivariable regression analysis identified that age, preoperative visual acuity and macular hole size were significant predictors of visual success. The resulting model correctly classified the visual outcome of 80% of cases. Predicted rates of visual success varied from 93% in patients <60 years old with visual acuity better than 6/24 and a hole diameter of <350 mum, to 2% in patients those >79 years old with visual acuity of 6/60 or worse and hole diameter of >500 microm.
The results provide a simple and clinically useful model to employ when counselling patients on macular hole surgery.
BACKGROUND/AIMS The advantages of logMAR acuity data over the Snellen fraction are well known, and yet existing logMAR charts have not been adopted into routine ophthalmic clinical use. As this may ...be due in part to the time required for a logMAR measurement, this study was performed to determine whether an abbreviated logMAR chart design could combine the advantages of existing charts with a clinically acceptable measurement time. METHODS The test-retest variability, agreement (with the gold standard), and time taken for “single letter” (interpolated) acuity measurements taken using three prototype “reduced logMAR” (RLM) charts and the Snellen chart were compared with those of the ETDRS chart which acted as the gold standard. The Snellen chart was also scored with the more familiar “line assignment” method. The subjects undergoing these measurements were drawn from a typical clinical outpatient population exhibiting a range of acuities. RESULTS The RLM A prototype chart achieved a test-retest variability of +/−0.24 logMAR compared with +/−0.18 for the ETDRS chart. Test-retest variability for the Snellen chart was +/−0.24 logMAR using clinically prohibitive “single letter” scoring increasing to +/−0.33 with the more usual “line assignment” method. All charts produced acuity data which agreed well with those of the ETDRS chart. “Single letter” acuity measurements using the prototype RLM charts were completed in approximately half the time of those taken using the ETDRS and Snellen charts. The duration of a Snellen “line assignment” measurement was not evaluated. CONCLUSION The RLM A chart offers an acceptable level of test-retest variability when compared with the gold standard ETDRS chart, while reducing the measurement time by half. Also, by allowing a faster, less variable acuity measurement than the Snellen chart, the RLM A chart can bring the benefits of logMAR acuity to routine clinical practice.
To develop and validate a classification system for focal vitreomacular traction (VMT) with and without macular hole based on spectral domain optical coherence tomography (SD-OCT), intended to aid in ...decision-making and prognostication.
A panel of retinal specialists convened to develop this system. A literature review followed by discussion on a wide range of cases formed the basis for the proposed classification. Key features on OCT were identified and analysed for their utility in clinical practice. A final classification was devised based on two sequential, independent validation exercises to improve interobserver variability.
This classification tool pertains to idiopathic focal VMT assessed by a horizontal line scan using SD-OCT. The system uses width (W), interface features (I), foveal shape (S), retinal pigment epithelial changes (P), elevation of vitreous attachment (E), and inner and outer retinal changes (R) to give the acronym WISPERR. Each category is scored hierarchically. Results from the second independent validation exercise indicated a high level of agreement between graders: intraclass correlation ranged from 0.84 to 0.99 for continuous variables and Fleiss' kappa values ranged from 0.76 to 0.95 for categorical variables.
We present an OCT-based classification system for focal VMT that allows anatomical detail to be scrutinised and scored qualitatively and quantitatively using a simple, pragmatic algorithm, which may be of value in clinical practice as well as in future research studies.
To briefly review and discuss the literature on vitrectomy for diabetic macular oedema.
Literature review.
There is a copious literature on the subject of vitrectomy for diabetic macular oedema ...(DMO). The most commonly hypothesised mechanism for the potential benefit of vitrectomy is relief of vitreomacular traction; however, both transvitreal oxygenation and improved growth factor diffusion away from the premacular retina have also been suggested to be potentially beneficial effects. Other systemic and local factors including duration of oedema, extent of ischaemia and exudation, and extent of laser may result in permanent photoreceptor and capillary damage, which precludes anatomical or visual benefit. Much of the literature on the subject of vitrectomy for DMO is retrospective and uncontrolled but strongly suggestive of a benefit in terms of improved acuity and reduced macular thickness following vitrectomy. There are five published small randomised controlled trials on this subject. Taken as a whole, these studies do not suggest a benefit from surgery. Selection of patients for surgery on the basis of OCT partial vitreomacular separation or clinical signs of traction such as an epiretinal membrane or taut thickened hyaloid has been reported to be associated with a modest improvement in prospective studies but this has not been subjected to controlled study.
The evidence at present suggests that vitrectomy for DMO should be restricted to those with clinical or OCT signs of traction.
To investigate the incidence and natural history of persistent subfoveolar fluid (PSF) following surgery for macular off rhegmatogenous retinal detachment and the effect of PSF on photoreceptor ...structure and final visual acuity.
Retrospective study of 61 cases with post-operative optical coherence tomography (OCT) performed within 12 weeks of surgery. Based on aetiology, cases were categorized into tractional retinal tears (TRT) group or atrophic round holes and dialyses (RHD) group to investigate the incidence and duration of PSF. A Kaplan-Meier graph was plotted to compare survival time of subfoveolar fluid for both groups. Following secondary reclassification of cases into those with and without PSF, the effect of PSF on final visual acuity and photoreceptor structure was investigated with Mann-Whitney U-test used for comparison. Spearman's correlation testing was used to probe associations between time to recorded resolution of PSF with final visual acuity and photoreceptor structure.
Incidence of PSF was greater in the RHD group and persisted for longer compared with TRT group. No detectable adverse effect of PSF on final visual acuity was seen however an individual case of severe photoreceptor atrophy was observed. No significant correlation was found between the time to recorded resolution of PSF and the final visual acuity or to photoreceptor grading scores.
A difference in incidence of PSF was detected between the aetiological groups. PSF was ubiquitous and slow to resolve in the RHD group. Most cases of PSF resolve without adverse sequelae; however, progressive photoreceptor atrophy and sub-optimal visual outcome may result in a minority.
Background Hypersensitivity reactions (HSRs) to chemotherapeutic drugs, including mAbs, often require that the provoking medication be discontinued, thus raising a dilemma for the caregiver: further ...use could precipitate a severe, even fatal, allergic reaction on re-exposure, but alternative drugs might be poorly tolerated or much less effective compared with the preferred agent. Objective We have developed a standardized rapid desensitization protocol for achieving temporary tolerization to drug allergens. In this study we evaluate the safety and efficacy of this protocol. Methods Ninety-eight patients who had HSRs in response to treatment with carboplatin, cisplatin, oxaliplatin, paclitaxel, liposomal doxorubicin, doxorubicin, or rituximab received rapid desensitization to these agents. A standardized 12-step protocol was used, with treatment given intravenously or intraperitoneally. Initial desensitizations occurred in the medical intensive care unit, whereas most subsequent infusions took place in an outpatient setting. Safety and efficacy of the protocol were assessed by review of treatment records. Results Of the 413 desensitizations performed, 94% induced mild or no reactions. No life-threatening HSRs or deaths occurred during the procedure, and all patients received their full target dose. Most reactions occurred during the first desensitization. Reactions were most commonly reported at the last step of the protocol. Desensitizations through the intravenous and intraperitoneal routes were equally effective. Conclusions Our standardized 12-step protocol for rapid drug desensitization is safe and effective and has been adopted as the standard of care at our institutions in treating patients with HSRs to chemotherapeutic drugs, including mAbs.
PurposeTo describe a survey of the use of ocriplasmin by members of the British and Eire Association of VitreoRetinal Surgeons (BEAVRS) for VitreoMacular Traction (VMT) and Full Thickness Macular ...Hole (FTMH) and compare it to published MIVI TRUST trial data.MethodsAll 173 BEAVRS members were contacted by email in October 2014 requesting data on all cases treated with ocriplasmin up to that date. The total number of cases, FTMH closure rate, VMT release rate and the frequency of adverse events were recorded. Results were compared with trial data.Results48 members responded reporting results from 241 eyes. The respective BEAVRS and MIVI TRUST trial closure rates for small FTMHs were 42.1 and 58.3% (P=0.09) and for medium FTMH 12.7 and 36.7% (P=0.01). The respective VMT release rates were 34.1 and 37.4% (P=NS). Retinal detachment was observed in 3.3% of the BEAVRS cohort compared with 0.4% in MIVI TRUST. Reduction in visual acuity to <6/60 was observed in 5.8% of the BEAVRS cohort and 0.6% in MIVI TRUST. Other complications not reported in the MIVI TRUST trial included an increase in FTMH basal diameter following unsuccessful ocriplasmin use in 46.9% of BEAVRS cases and zonular instability at the time of subsequent phacoemulsification in 2.4%.ConclusionMacular hole closure rates were lower in the BEAVRS survey than published in the MIVI TRUST trial data. The incidence of adverse events was greater than previously reported. The reasons for these disparities are unknown but could include positive reporting bias inherent to retrospective surveys, treatment and population differences.
The aim of the study was to compare the performance of two different COMPlog computerised, single letter scoring, visual acuity (VA) measurements against gold standard Early Treatment Diabetic ...Retinopathy Study (ETDRS) chart measurements in patients with age-related macular degeneration (AMD). One computerised algorithm presented five and the other presented three letters per line; both computerised algorithms utilised half, rather than the full-letter width spacing standard on ETDRS charts that might induce crowding, fixation problems, increased test-retest variability (TRV), and bias.
Fifty patients with AMD (mean age 83 years) underwent timed test and retest VA measurements using ETDRS charts and COMPlog five (C5) and three (C3) letters per line computerised VA measurement algorithms. All tests utilised single-letter scoring methodology. Bland and Altman methods were employed. Performance was measured in terms of bias, TRV, and test time.
The C5 and C3 scores showed no bias compared with the ETDRS chart measurements. C5 measurements had equal TRV to the ETDRS chart (±0.13 logMAR) with similar median test times (105 and 96 s, respectively). C3 measurements were slightly more variable (TRV ±0.17 logMAR), but 30 s quicker than ETDRS chart measurements.
The closer letter spacing employed in COMPlog testing algorithms appears to have no adverse effect on VA measurements compared with the gold standard ETDRS chart in patients with AMD. The three letter per line testing algorithm facilitates faster testing but with a two letter increase in TRV.