Neuroretinal rim (NRR) measurement can aid the diagnosis of glaucoma. A few studies reported that Cirrus optical coherence tomography (OCT) had NRR segmentation errors. The current study investigated ...segmentation success of NRR in myopic eyes using the Cirrus built-in software and to determine the number of acquisitions required to identify NRR thinning. Right eye of 87 healthy adult myopes had an optic disc scanned using Cirrus HD-OCT for five successive acquisitions. A masked examiner evaluated 36 radial line images of each scan to screen for segmentation errors using the built-in software at the Bruch's membrane opening (BMO) and/or internal limiting membrane (ILM). Participants with three accurate NRR acquisitions had their average NRR thickness determined. This result was compared with average of the two acquisitions and the first acquisition. Among 435 OCT scans of the optic disc (87 eyes × 5 acquisitions), 129 (29.7%) scans had segmentation errors that occurred mainly at the ILM. The inferior-temporal and superior meridians had slightly more segmentation errors than other meridians, independent of axial length, amount of myopia, or presence of peripapillary atrophy. Sixty-five eyes (74.7%) had at least three accurate NRR measurements. The three acquisitions had high reliability in NRR thickness in the four quadrants (intraclass correlation coefficient > 0.990, coefficient of variation < 3.9%). NRR difference between the first acquisition and the average of three acquisitions was small (mean difference 2 ± 13 μm, 95% limits of agreement within ± 30 μm) among the four quadrants. Segmentation errors in NRR measurements appeared regardless of axial length, amount of myopia, or presence of peripapillary atrophy. Cirrus segmentation lines should be manually inspected when measuring NRR thickness.
Circulating cell-free Epstein-Barr virus (EBV) DNA is a biomarker for nasopharyngeal carcinoma. We conducted a prospective study to investigate whether EBV DNA in plasma samples would be useful to ...screen for early nasopharyngeal carcinoma in asymptomatic persons.
We analyzed EBV DNA in plasma specimens to screen participants who did not have symptoms of nasopharyngeal carcinoma. Participants with initially positive results were retested approximately 4 weeks later, and those with persistently positive EBV DNA in plasma underwent nasal endoscopic examination and magnetic resonance imaging (MRI).
A total of 20,174 participants underwent screening. EBV DNA was detectable in plasma samples obtained from 1112 participants (5.5%), and 309 (1.5% of all participants and 27.8% of those who initially tested positive) had persistently positive results on the repeated sample. Among these 309 participants, 300 underwent endoscopic examination, and 275 underwent both endoscopic examination and MRI; of these participants, 34 had nasopharyngeal carcinoma. A significantly higher proportion of participants with nasopharyngeal carcinoma that was identified by screening had stage I or II disease than in a historical cohort (71% vs. 20%, P<0.001 by the chi-square test) and had superior 3-year progression-free survival (97% vs. 70%; hazard ratio, 0.10; 95% confidence interval, 0.05 to 0.18). Nine participants declined to undergo further testing, and 1 of them presented with advanced nasopharyngeal carcinoma 32 months after enrollment. Nasopharyngeal carcinoma developed in only 1 participant with negative EBV DNA in plasma samples within 1 year after testing. The sensitivity and specificity of EBV DNA in plasma samples in screening for nasopharyngeal carcinoma were 97.1% and 98.6%, respectively.
Analysis of EBV DNA in plasma samples was useful in screening for early asymptomatic nasopharyngeal carcinoma. Nasopharyngeal carcinoma was detected significantly earlier and outcomes were better in participants who were identified by screening than in those in a historical cohort. (Funded by the Kadoorie Charitable Foundation and the Research Grants Council of the Hong Kong government; ClinicalTrials.gov number, NCT02063399 .).
Change in intraocular pressure during acute ocular compression is related to aqueous humour dynamics. Monitoring intraocular pressure (IOP) change throughout ocular compression has potential to ...evaluate aqueous outflow facilities.
Recent studies have monitored lamina cribrosa deformation using optical coherence tomography during ocular compression. IOP was measured only once immediately after ocular compression. This study aimed to evaluate IOP changes during and after ocular compression and compare the differences between low and high myopia.
Two groups of young, healthy adults were age-matched and underwent ocular compression. IOP was measured at baseline and monitored during a 2-min ocular compression followed by a 10-min recovery phase. Rebound tonometry was used and applied at 30-s intervals.
Thirty low and 30 high myopes (60 right eyes) were included in the study. They had similar baseline IOP at 14.9 mmHg. IOP was elevated to 21.7 ± 3.8 mmHg and 22.3 ± 4.2 mmHg for the low and high myopic group, respectively (p = 0.877). Low myopes had faster IOP decay during ocular compression at −3.24 mmHg/min than high myopes at −2.58 mmHg/min (p = 0.0528). The IOP dropped below the baseline level after the release of the compressive force. Low myopes had IOP that returned to baseline levels faster (at 360 s) than high myopes (at 510 s).
Measuring IOP once immediately after ocular compression could under-estimate the effect of IOP elevation during ocular compression. Further studies are required regarding IOP changes from ocular compression in aqueous humour dynamics.
Although contrast-enhanced magnetic resonance imaging (MRI) detects early-stage nasopharyngeal carcinoma (NPC) not detected by endoscopic-guided biopsy (EGB), a short contrast-free screening MRI ...would be desirable for NPC screening programs. This study evaluated a screening MRI in a plasma Epstein-Barr virus (EBV)-DNA NPC screening program.
EBV-DNA-screen-positive patients underwent endoscopy, and endoscopy-positive patients underwent EGB. EGB was negative if the biopsy was negative or was not performed. Patients also underwent a screening MRI. Diagnostic performance was based on histologic confirmation of NPC in the initial study or during a follow-up period of at least 2 years.
The study prospectively recruited 354 patients for MRI and endoscopy; 40/354 (11.3%) endoscopy-positive patients underwent EGB. Eighteen had NPC (5.1%), and 336 without NPC (94.9%) were followed up for a median of 44.8 months. MRI detected additional NPCs in 3/18 (16.7%) endoscopy-negative and 2/18 (11.1%) EGB-negative patients (stage I/II, n = 4; stage III, n = 1). None of the 24 EGB-negative patients who were MRI-negative had NPC. MRI missed NPC in 2/18 (11.1%), one of which was also endoscopy-negative. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI, endoscopy, and EGB were 88.9%, 91.1%, 34.8%, 99.4%, and 91.0%; 77.8%, 92.3%, 35.0%, 98.7%, and 91.5%; and 66.7%, 92.3%, 31.6%, 98.1%, and 91.0%, respectively.
A quick contrast-free screening MRI complements endoscopy in NPC screening programs. In EBV-screen-positive patients, MRI enables early detection of NPC that is endoscopically occult or negative on EGB and increases confidence that NPC has not been missed.
Digital ocular massage has been reported to temporarily lower intraocular pressure (IOP). This could be related to an enhanced aqueous humor outflow; however, the mechanism is not clearly understood. ...Using anterior segment optical coherence tomography, the Schlemm's canal (SC) and trabecular meshwork (TM) can be imaged and measured. Here, 66 healthy adults underwent digital ocular massage for 10 min in their right eyes. The IOP and dimensions of the SC and TM were measured before and after ocular massage. All subjects demonstrated IOP reduction from 15.7 ± 2.5 mmHg at baseline to 9.6 ± 2.2 mmHg immediately after, and median of 11.6 mmHg 5-min after ocular massage (Friedman's test, p < 0.001). There was significant change in SC area (median 10,063.5 μm
at baseline to median 10,151.0 μm
after ocular massage, Wilcoxon test, p = 0.02), and TM thickness (median 149.8 μm at baseline to 144.6 ± 25.3 μm after ocular massage, Wilcoxon test, p = 0.036). One-third of the subjects demonstrated collapse of the SC area (-2 to -52%), while two-thirds showed expansion of the SC area (2 to 168%). There were no significant changes in SC diameter (270.4 ± 84.1 μm vs. 276.5 ± 68.7 μm, paired t-test, p = 0.499), and TM width (733.3 ± 110.1 μm vs. 733.5 ± 111.6 μm, paired t-test, p = 0.988). Eyes with a higher baseline IOP demonstrated a greater IOP reduction (Pearson correlation coefficient r = -0.521, p < 0.001). Eyes with smaller SC area at baseline showed greater SC area expansion (Pearson correlation coefficient = -0.389, p < 0.001). Greater IOP reduction appeared in eyes with greater SC area expansion (Pearson correlation coefficient r = -0.306, p = 0.01). Association between change in IOP and change in TM thickness was not significant (Spearman's ρ = 0.015, p = 0.902). Simple digital ocular massage is an effective method to lower IOP values, and change in the SC area was significantly associated with IOP changes.
Myopia is very prevalent worldwide, especially among Asian populations. Orthokeratology is a proven intervention to reduce myopia progression. The current study investigated association between ...baseline corneal biomechanics and orthokeratology responses, and changes of corneal biomechanics from long-term orthokeratology. We fitted 59 adult subjects having myopia between -4.00D to -5.00D with overnight orthokeratology. Corneal biomechanics was measured through dynamic bidirectional corneal applanation (in terms of corneal hysteresis, CH and corneal resistance factor, CRF) and corneal indentation (in terms of corneal stiffness, S and tangent modulus, E). Subjects with poor orthokeratology responses had lower E (mean 0.474 MPa) than subjects with good orthokeratology responses (mean 0.536 MPa). Successful orthokeratology for 6 months resulted in reducing CH (reduced by 5.8%) and CRF (reduced by 8.7%). Corneal stiffness was stable, but E showed an increasing trend. Among subjects with successful orthokeratology, a higher baseline S resulted in greater myopia reduction (Pearson correlation coefficient, r = 0.381, p = 0.02).
Electronic devices have become an indispensable part of our daily lives. The frequency and duration of device use in children and adolescents have increased drastically over the years and the study ...of its negative musculoskeletal, visual and psychosocial health impacts is necessary.
This cross-sectional study aimed to evaluate the associations between electronic device use and the prevalence and severity of musculoskeletal symptoms, visual symptoms, psychosocial health, and quality of life in children and adolescents studying at primary and secondary schools. Data were collected through confidential online and paper-and-pencil questionnaires. Primary 4-5 and Secondary 1-4 students were recruited from 3 schools in Hong Kong. Demographics, frequency and duration of electronic device use, frequencies of musculoskeletal symptoms, visual symptoms, psychosocial health, and quality of life outcomes were measured.
1,058 children and adolescents aged 9-17 years participated. Sixty-one percent and 78% of all students spent more than 2 h per day using electronic devices during school days and weekend/holidays, respectively. Extended electronic device use was associated with increased prevalence and severity of musculoskeletal symptoms (ρ's = 0.28-0.33, P's < 0.001), visual symptoms (ρ's = 0.33-0.35, P's < 0.001), and poorer device use-related psychosocial health (ρ's = 0.38-0.47, P's < 0.001). Secondary school students reported greater device use and severity of symptoms than primary school students.
Excessive electronic device use was associated with increased prevalence and severity of physical and psychosocial symptoms, and such use is more prevalent in adolescents when compared to the children. The findings have important health implications for children and adolescents, suggesting that early intervention is needed to reduce the risk of developing device use-related disorders.
To study the intrasession and intersession repeatability of the Pentacam system (Oculus Inc.) in measuring the posterior corneal shape.
School of Optometry, Hong Kong Polytechnic University, Hong ...Kong, China.
The posterior corneal shape in 1 eye (randomly selected) was measured with the Pentacam system. Three consecutive readings were taken for intrasession repeatability analysis. Measurements were repeated 1 to 2 weeks later for intersession repeatability analysis. The anterior best-fit sphere (BFS) and posterior BFS at the 5.0 mm and 8.0 mm zones, as well as the elevation of the posterior cornea at these 2 zones, were compared.
The anterior and posterior BFS demonstrated good intrasession repeatability (Cronbach alpha > or = 0.997; intraclass correlation coefficients > or = 0.990). No significant difference was found between the 2 visits. The 95% limits of agreement of posterior BFS were 52.3 to -41.7 microm at the 5.0 mm zone and 66.1 to -60.9 microm at the 8.0 mm zone. The elevation was similar between the 2 visits. The 95% limits of agreement were 4.27 to -5.29 microm at the 5.0 mm zone and 5.33 to -5.77 microm at the 8.0 mm zone.
Pentacam provided good performance in assessing the posterior cornea. To improve the intersession repeatability, it is suggested that 3 consecutive readings, rather than 1 image, be taken to generate an average BFS for analysis. When comparing the posterior corneal elevation between sessions, an average BFS generated from the first visit should be used for elevation calculation.
Currently available clinical devices are unable to measure corneal biomechanics other than at the central region. Corneal stiffness (S), thickness, and radius of curvature was measured at the central ...cornea (primary fixation) and 3 mm from the temporal limbus (primary and nasal fixations). The corneal tangent modulus (E) of 25 healthy subjects was calculated from these data. After confirming normality, repeated measures analysis of variance (RMANOVA) revealed significant difference in S (F(2, 48) = 21.36, p < 0.001) at different corneal regions and direction of fixations. E also varied significantly at different corneal regions and direction of fixations (RMANOVA: F(2, 48) = 23.06, p < 0.001). A higher S and a lower E were observed at the temporal region compared with the corneal centre. Nasal fixation further increased S and E values compared with primary fixation. Due to the specific arrangement of corneal collagen fibrils, heterogeneity of corneal biomechanical properties is expected. In future clinical practice, localized corneal biomechanical alternation and measurement might assist corneal disease detection and post-surgery management. In addition, practitioners should be aware of the fixation effect on corneal biomechanical measurement.
Optical coherence tomography angiography (OCTA) is widely used in ophthalmic practice. Most OCTA studies based their findings on a single OCTA measurement. We conducted an observational study of 82 ...eyes from 82 healthy subjects to compare variations of OCTA parameters among five successive measurements. A 3 × 3 mm Early Treatment of Diabetic Retinopathy Study grid centred at fovea was used. An average from five successive OCTA measurements (both perfusion density and vessel density) was calculated to be used as the reference standard. There was no significant difference in perfusion and vessel densities among five successive OCTA measurements, and from different levels of averaging. Perfusion density was close to the reference standard when average from three measurements was used (discrepancy within 1.5%) as compared with using just one measurement (discrepancy from 3.2% to 4.5%). Vessel density was also close to reference standard when average from three measurements was used (within 0.8 mm
) as compared with using just one measurement (2 mm
). Software feature that allows OCTA devices to average quantitative parameters for analysis will be useful.