In a prospective, multicentre double-blind trial, 151 patients over the age of 65 years were randomly assigned to receive either cefepime 2 g every 12 h for a minimum of 3 days and up to 14 days or ...ceftriaxone 1 g every 12 h for a minimum of 3 days and up to 14 days. Antibiotics were maintained until 48 h after fever had resolved; no other antibiotics were permitted. The average age in each group exceeded 77 years and significant co-morbidity was found in the majority of patients. The mean total duration of therapy was 5.8+/-2.4 days for the cefepime group and 6.7+/-2.7 days for the ceftriaxone group (P = 0.06). The clinical success rate at the end of therapy was 79.1% with cefepime and 75.4% with ceftriaxone (P = 0.62). At the end of follow-up, 91.7% of the cefepime-treated patients and 86.5% of the ceftriaxone patients had a satisfactory clinical response (P = 0.38). In 35 bacteriological evaluable patients, potential pathogens were eradicated in all but one patient receiving cefepime. Seven patients in each group died during the study period but in each case the death was unrelated to study drug. The commonest side-effect was diarrhoea (cefepime, five patients; ceftriaxone, two patients). The clinical and microbiological efficacy of cefepime is similar to that of ceftriaxone in elderly patients with community-acquired pneumonia requiring hospitalization. Cefepime is an appropriate choice for the treatment of community-acquired respiratory tract infections in the elderly.
Spectra of highly charged Kr ions, produced in an electron-beam ion trap (EBIT), have been recorded in a broad x-ray energy band (0.3 keV to 4 keV) with a microcalorimeter detector. Most of the ...spectral lines have been identified as transitions of B- to Al-like Kr. The transition energies have been determined with 0.2% uncertainty. A semi-empirical EBIT plasma model has been created to calculate a synthetic spectrum of highly charged Kr and to determine a charge state distribution of Kr ions inside the EBIT.
There is an ongoing debate in cognitive neuroscience about the time course and the functional independence of the different processes involved in encoding written language material. New data indicate ...very fast and highly parallel language analysis networks in the brain. Here we demonstrate a methodological approach to study the temporal dynamics of this network by searching for time periods where different task demands emphasize different aspects of the network. Multi-channel event related potentials (ERPs) were recorded during a semantic and a phonological reading task from 14 healthy subjects. Signals were analyzed exclusively on the basis of the spatial configuration of the electric potential distributions (ERP maps), since differences in these spatial patterns directly reflect changes in the configuration of the active sources in the brain. This analysis did not reveal any differences of the evoked brain electric fields between the two tasks up to 280 ms post-stimulus. The ERP maps then differed for a brief period between 280 and 380 ms, before they were similar again. The analysis of the maps using a global linear localization procedure revealed a network of areas, active in both tasks, that mainly involved the left postero-temporal and left antero-temporal regions. The left posterior activation was found already around 100 ms post-stimulus, indicating that language-specific functions appear early in time. We therefore conclude that phonological and semantic processing are essentially performed in both tasks and that only late decision-related processes influence the relative strength of activity of the different modules in the complex language network.
A new particle, the cosmion, has been proposed to be the dark matter of the universe and to explain the solar nu deficit by cooling the solar core to reduce B-8 nu production. Such cosmions in the ...galactic halo would scatter from nuclei in terrestrial detectors. Measurements were made in Si ionization detectors in a very-low-background environment down to energies of 1.1 keV. These results exclude nearly all of the mass range possible for cosmions with coherent nuclear interactions. (Author)