This study aimed to apply minimum-time variable-rate selective excitation (MinVER) to a presaturation pulse (PSP) with a high flip angle on 7 T time-of-flight magnetic resonance angiography (7T ...TOF-MRA), to attain a superior vessel-to-tissue contrast (VTCR), short acquisition time, and minor off-resonance effect. An altered PSP modified by using the 90° flip angle (FA)-MinVER was implemented in the 7 T TOF-MRA, and its performance was evaluated with a signal profile and vessel-tissue contrast ratios and compared to the conventional PSP and 45 FA-TOF. The 90 FA-MinVER showed a similar signal profile to that of the conventional PSP and improved the vessel-tissue contrast ratios (0.313 ± 0.80) compared to all conventional types (45 FA-TOF: 0.088 ± 0.84, 90 FA-TOF: 0.203 ± 0.72). Moreover, this noteworthy approach achieved substantially reduced total acquisition time (5 min and 55 s) with a short repeat-to-time (28 ms), indicating that at the 7 T TOF-MRA, the 90 FA-MinVER could be applied by default to suppress the venous signals regardless of individual human status and the specific absorption ratio constraint and with rapid imaging. Ultimately, its application could also help to observe subtle microvascular changes in the early stages and serve as key biomarkers in various vascular diseases.
The core body temperature tends to decrease under general anesthesia. Consequently, monitoring the core body temperature during procedures involving general anesthesia is essential to ensure patient ...safety. In veterinary medicine, rectal temperature is used as an indicator of the core body temperature, owing to the accuracy and convenience of this approach. Some previous studies involving craniotomy reported differences between the brain and core temperatures under general anesthesia. However, noninvasive imaging techniques are required to ascertain this because invasive brain temperature measurements can cause unintended temperature changes by inserting the temperature sensors into the brain or by performing the surgical operations. In this study, we employed in vivo magnetic resonance thermometry to observe the brain temperatures of patients under general anesthesia using the proton resonance frequency shift method. The rectal temperature was also recorded using a fiber optic thermometer during the MR thermometry to compare with the brain temperature changes. When the rectal temperature decreased by 1.4 ± 0.5 °C (mean ± standard deviation), the brain temperature (white matter) decreased by 4.8 ± 0.5 °C. Furthermore, a difference in the temperature reduction of the different types of brain tissue was observed; the reduction in the temperature of white matter exceeded that of gray matter mainly due to the distribution of blood vessels in the gray matter. We also analyzed and interpreted the core temperature changes with the body conditioning scores of subjects to see how the body weight affected the temperature changes.
Abstract Research into multifunctional nanoparticles is focused on creating an agent for use in an all-in-one multimodal imaging system that includes diagnostic imaging, drug delivery, and ...therapeutic monitoring. We designed a new dual-modality tumor-targeting agent with a new tumor-targeting molecule, oleanolic acid (OA), which is derived from a natural compound and coupled with a macrocyclic chelating agent such as 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA), iron oxide nanoparticles (IONP), and radiolabeling components such as68 Ga for dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI). We attempted to obtain fusion PET/MR images with the68 Ga–NOTA–OA–IONP hybrid tumor-targeting imaging agent using colon cancer (HT-29) xenograft mice models. The HT-29 cancer cells showed high uptake of68 Ga–NOTA–OA–IONP, which also had an inhibitory effect on the cells. Moreover, we obtained PET and MRI tumor images as well as fusion PET/MRI images of the tumors using68 Ga–NOTA–OA–IONP. Therefore, the dual-modality cancer-targeting radiolabeled nanoparticle reported here is a potent imaging agent that is suitable for PET, MRI, and PET/MRI-based diagnosis of tumors; it also has the advantage of not only detecting tumor functionality, but also simultaneously aiding in tumor resolution.
In magnetic resonance imaging, the fidelity of image reconstruction is an important criterion. It has been suggested that the infinite-extent sinc kernel is the ideal interpolation kernel for ...ensuring the reconstruction quality of non-Cartesian trajectories. However, the application of the sinc function has been limited owing to its computational overheads. Recently, graphics processing units (GPUs) have been employed as fast computation tools because of their efficient and versatile parallel computation abilities. We implemented an accelerated convolution function with the sinc kernel using GPUs computing and evaluated the reconstruction performance. The computation time was significantly improved: Computation using the proposed method was approximately 270 times faster than that on a central processing unit (CPU) and approximately 4.6 times faster than that on a CPU optimized by level-3 Basic Linear Algebra Subprograms. The images reconstructed using the fast sinc function exhibited no adverse errors at all matrix sizes (resolutions). The total reconstruction time was approximately 0.3–3 s for all matrices, indicating that the sinc function could be a practical option for image reconstruction. Ultimately, its application would present a fundamental improvement to the performance of image reconstruction, and the GPU implementation of the convolution function with the sinc kernel could resolve various challenges in image data processing.
Radiofrequency (RF) transmit field (B1) mapping is a promising method in mitigating the B1 inhomogeneity in various magnetic resonance imaging (MRI) applications. Although several phase- or ...magnitude-based B1 mapping methods have been proposed, these methods often require complex modeling, long acquisition time, or specialized MRI sequences. A recently introduced simultaneous echo refocusing (SER) technique can be applied in the B1 mapping method to extend the three-dimensional (3D) spatial coverage only without long data acquisition. Therefore, in this study, a multislice B1 mapping method using composite spin echo sequences and SER techniques is proposed to obtain more accurate B1 mapping with short data acquisition time. To evaluate the performance of the proposed B1 mapping method, computational simulations were performed and compared with Morrell’s method, double angle method, and Yarnykh’s method. These results showed that the angle-to-noise ratio of the proposed B1 mapping method has wider B1 range compared to that of other B1 mapping methods. In addition, the proposed B1 mapping methods were compared to the multislice iterative signal intensity mapping method in both phantom and in vivo human experiments, and there was no remarkable difference between the two methods regarding the flip angle distribution in these experiments. Based on these results, this study demonstrated that the proposed B1 mapping method is suitable for accurately measuring B1 propagation under the condition providing reduced scan time and wider 3D coverage of B1 mapping by applying composite RF pulse and SER techniques into the phase-sensitive method.
Pyrrolizidine alkaloids (PAs) that are plant toxin naturally produced for protection against herbivores in some plant families. They are associated with the potential hepatotoxic and carcinogenic ...diseases serious hepatic disease in humans and animals. As the concern of human health risk posed by exposure to PAs has been gradually increased, precise and reliable analysis is required for monitoring PAs. The present study developed a new and simple pretreatment using 50% MeOH (methanol) for quantification analysis of the PAs contained with high content in the herbal medicines. Another pretreatment method using cation-ion exchange solid-phase extraction (MCX-SPE) was employed for determining most of the PAs that are not contained in the herbal medicines. That is, the proposed LC–MS/MS method coupled with MCX-SPE extraction and 50% MeOH extraction method was developed. And to evaluate the reliability of its application for Farfarae Flos and Lithospermi Radix, a validation study was conducted. In addition, monitory study was performed with ten samples in each herbal medicine. As a result, the proposed method had good linearity with r
2
≥ 0.997. Also, the recoveries indicated to be in the ranges of 70.4–118.0% for the Farfarae Flos, 70.2–119.7% for the Lithospermi Radix. In two herbal medicines, the intra-day precision was revealed to satisfy the reference criteria in most of the PAs. In monitoring results, most of the PAs were not contained in two herbal medicines, whereas a part of PAs revealed to have high concentration in Farfarae Flos and Lithospermi Radix. The proposed method is considered as a simple and reliable method to quantify 28 PAs present in two herbal medicines. Especially, the simple MeOH extraction method seems to be available for quantification analysis of certain PAs in herbal medicines with high content.
This work investigates the construction and performance of an eight-channel top-hat dipole receiver RF coil with a capacitive plate to increase the longitudinal whole-brain coverage and receiver ...sensitivity gain in the brain at 7 T MRI. The construction method for top-hat dipole-based receiver RF coil by adjusting the length and structure corresponding to each channel consists of tuning, matching, balun, and detuning circuitry. Electromagnetic simulations were analyzed on a 3-D human model to evaluate
B
1
+
efficiency and specific absorption rate deposition. Coil performance was evaluated in the human head imaging in vivo. EM simulation results indicated a higher
B
1
−
sensitivity in the brain and z-directional coverage of the proposed eight-channel receiver RF coil. The MR images were acquired with an identical field of view showing the receiver coverage improvement in the brain when capacitive plates are used. The MR images also show the clear visibility of the complete set of the cervical vertebrae as well as the spinal cord. The acquired MRI results demonstrate the capability of the proposed RF coil to increase the receiver coverage in the longitudinal direction. Moreover, the
B
1
+
efficiency, as well as receiver sensitivity in the brain, can be substantially improved with the use of multilayered capacitive plates of proper shape and size in conjunction with an RF coil.
Gram-negative bacterial endotoxins can cause pathophysiological effects such as high fever when introduced into the bloodstream. Therefore, endotoxin testing is necessary when producing injectable ...pharmaceuticals. The pharmaceutical industry has widely used
amebocyte lysate (LAL) to certify product quality. However, ethical concerns have been raised and the increasing scarcity of
necessitates the development of novel testing techniques. Recombinant factor C (rFC) was developed using genetic engineering techniques. The aim of this study was to investigate the validity of rFC testing and compare it with the LAL method. The specificity, linearity, accuracy, precision, and robustness of the rFC assay were evaluated. After validation, the rFC assay was found to be suitable for endotoxin detection. We compared the accuracy of the rFC and LAL assays using reference standard endotoxin. The rFC assay was as accurate as the LAL assay. We also compared the two assays using biopharmaceuticals. Greater interference occurred in some samples when the rFC assay was used than when the LAL assay was used. However, the rFC assay overcame the interference when the samples were diluted. Overall, we suggest that rFC can be applied to test biopharmaceuticals.
The graphite encapsulation of metal alloy magnetic nanoparticles has attracted attention for biological applications because of the high magnetization of the encapsulated particles. However, most of ...the synthetic methods have limitations in terms of scalability and economics because of the demanding synthetic conditions and low yields. Here, we show that well controlled graphite-encapsulated FeCo core-shell nanoparticles can be synthesized by a hydrothermal method, simply by mixing Fe/Co with sucrose as a carbon source. Various Fe/Co metal ratios were used to determine the compositional dependence of the saturation magnetization and relaxivity coefficient. Transmission electron microscopy indicated that the particle sizes were 7 nm. In order to test the capability of graphite-encapsulated FeCo nanoparticles as magnetic resonance imaging (MRI) contrast agents, these nanoparticles were solubilized in water by the nonspecific physical adsorption of sodium dodecylbenzene sulfonate.
We describe a simple method for synthesizing superparamagnetic nanoparticles (SPIONs) as small, stable contrast agents for magnetic resonance imaging (MRI) based on sulfobetaine zwitterionic ligands. ...SPIONs synthesized by thermal decomposition were coated with zwitterions to impart water dispersibility and high in vivo stability through the nanoemulsion method. Zwitterion surfactant coating layers are formed easily on oleic acid-stabilized SPIONs via hydrophobic and van der Waals interactions. Our zwitterion-coated SPIONs (ZSPIONs) had ultrathin (∼5 nm) coating layers with mean sizes of 12.0 ± 2.5 nm, as measured by dynamic light scattering (DLS). Upon incubation in 1 M NaCl and 10% FBS, the ZSPIONs showed high colloidal stabilities without precipitating, as monitored by DLS. The T2 relaxivity coefficient of the ZSPIONs, obtained by measuring the relaxation rate on the basis of the iron concentration, was 261 mM–1 s–1. This value was much higher than that of the commercial T2 contrast agent because of the ultrathin coating layer. Furthermore, we confirmed that ZSPIONs can be used as MR contrast agents for in vivo applications such as tumor imaging and lymph node mapping.