We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses (mχ) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on ...time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg day exposure and 250 eVee threshold for AM analysis. The sensitive windows in mχ are expanded by an order of magnitude to lower DM masses with Migdal effect incorporated. New limits on σχNSI at 90% confidence level are derived as 2×10−32∼7×10−35 cm2 for TI analysis at mχ∼50–180 MeV/c2, and 3×10−32∼9×10−38 cm2 for AM analysis at mχ∼75 MeV/c2–3.0 GeV/c2.
We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China ...Jinping Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8×10^{-42} and 3×10^{-36} cm^{2} at a 90% confidence level on spin-independent and spin-dependent WIMP-nucleon cross sections, respectively, at a WIMP mass (m_{χ}) of 5 GeV/c^{2} are achieved. The lower reach of m_{χ} is extended to 2 GeV/c^{2}.
Avermectins are major antiparasitic agents used commercially in animal health, agriculture and human infections. To improve the fermentation efficiency of avermectins, for the first time a plasma jet ...generated by a novel atmospheric pressure glow discharge (APGD) was employed to generate mutations in Streptomyces avermitilis. The APGD plasma jet, driven by a radio frequency (RF) power supply with water-cooled and bare-metallic electrodes, was used as a new mutation method to treat the spores of S. avermitilis. The plasma jet yielded high total (over 30%) and positive (about 21%) mutation rates on S. avermitilis, and a mutated strain, designated as G1-1 with high productivity of avermectin B1a and genetic stability, was obtained. Because of the low jet temperature, the high concentrations of the chemically reactive species and the flexibility of its operation, the RF APGD plasma jet has a strong mutagenic effect on S. avermitilis. This is a proof-of-concept study for the use of an RF APGD plasma jet for inducing mutations in microbes. We have shown that the RF APGD plasma jet could be developed as a promising and convenient mutation tool for the fermentation industry and for use in biotechnology research.
Occult peritoneal metastasis (PM) in advanced gastric cancer (AGC) patients is highly possible to be missed on computed tomography (CT) images. Patients with occult PMs are subject to late detection ...or even improper surgical treatment. We therefore aimed to develop a radiomic nomogram to preoperatively identify occult PMs in AGC patients.
A total of 554 AGC patients from 4 centers were divided into 1 training, 1 internal validation, and 2 external validation cohorts. All patients’ PM status was firstly diagnosed as negative by CT, but later confirmed by laparoscopy (PM-positive n = 122, PM-negative n = 432). Radiomic signatures reflecting phenotypes of the primary tumor (RS1) and peritoneum region (RS2) were built as predictors of PM from 266 quantitative image features. Individualized nomograms of PM status incorporating RS1, RS2, or clinical factors were developed and evaluated regarding prediction ability.
RS1, RS2, and Lauren type were significant predictors of occult PM (all P < 0.05). A nomogram of these three factors demonstrated better diagnostic accuracy than the model with RS1, RS2, or clinical factors alone (all net reclassification improvement P < 0.05). The area under curve yielded was 0.958 95% confidence interval (CI) 0.923–0.993, 0.941 (95% CI 0.904–0.977), 0.928 (95% CI 0.886–0.971), and 0.920 (95% CI 0.862–0.978) for the training, internal, and two external validation cohorts, respectively. Stratification analysis showed that this nomogram had potential generalization ability.
CT phenotypes of both primary tumor and nearby peritoneum are significantly associated with occult PM status. A nomogram of these CT phenotypes and Lauren type has an excellent prediction ability of occult PM, and may have significant clinical implications on early detection of occult PM for AGC.
We present improved germanium-based constraints on sub-GeV dark matter via dark matter-electron (χ-e) scattering using the 205.4 kg·day dataset from the CDEX-10 experiment. Using a novel calculation ...technique, we attain predicted χ-e scattering spectra observable in high-purity germanium detectors. In the heavy mediator scenario, our results achieve 3 orders of magnitude of improvement for m_{χ} larger than 80 MeV/c^{2} compared to previous germanium-based χ-e results. We also present the most stringent χ-e cross-section limit to date among experiments using solid-state detectors for m_{χ} larger than 90 MeV/c^{2} with heavy mediators and m_{χ} larger than 100 MeV/c^{2} with electric dipole coupling. The result proves the feasibility and demonstrates the vast potential of a new χ-e detection method with high-purity germanium detectors in ultralow radioactive background.
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass p-type point-contact germanium detector of the CDEX-1B ...experiment at the China Jinping Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2-yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus (χ-N) spin-independent cross sections as function of WIMP mass (m_{χ}) at 90% confidence level (C.L.) are derived using the dark matter halo model. Within the context of the standard halo model, the 90% C.L. allowed regions implied by the DAMA/LIBRA and CoGeNT AM-based analysis are excluded at >99.99% and 98% C.L., respectively. These results correspond to the best sensitivity at m_{χ}<6 GeV/c^{2} among WIMP AM measurements to date.
A Nationwide Nitrogen Deposition Monitoring Network (NNDMN) containing 43 monitoring sites was established in China to measure gaseous NH3, NO2, and HNO3 and particulate NH4+ and NO3− in air and/or ...precipitation from 2010 to 2014. Wet/bulk deposition fluxes of Nr species were collected by precipitation gauge method and measured by continuous-flow analyzer; dry deposition fluxes were estimated using airborne concentration measurements and inferential models. Our observations reveal large spatial variations of atmospheric Nr concentrations and dry and wet/bulk Nr deposition. On a national basis, the annual average concentrations (1.3–47.0 μg N m−3) and dry plus wet/bulk deposition fluxes (2.9–83.3 kg N ha−1 yr−1) of inorganic Nr species are ranked by land use as urban > rural > background sites and by regions as north China > southeast China > southwest China > northeast China > northwest China > Tibetan Plateau, reflecting the impact of anthropogenic Nr emission. Average dry and wet/bulk N deposition fluxes were 20.6 ± 11.2 (mean ± standard deviation) and 19.3 ± 9.2 kg N ha−1 yr−1 across China, with reduced N deposition dominating both dry and wet/bulk deposition. Our results suggest atmospheric dry N deposition is equally important to wet/bulk N deposition at the national scale. Therefore, both deposition forms should be included when considering the impacts of N deposition on environment and ecosystem health.
Preoperative evaluation of the number of lymph node metastasis (LNM) is the basis of individual treatment of locally advanced gastric cancer (LAGC). However, the routinely used preoperative ...determination method is not accurate enough.
We enrolled 730 LAGC patients from five centers in China and one center in Italy, and divided them into one primary cohort, three external validation cohorts, and one international validation cohort. A deep learning radiomic nomogram (DLRN) was built based on the images from multiphase computed tomography (CT) for preoperatively determining the number of LNM in LAGC. We comprehensively tested the DLRN and compared it with three state-of-the-art methods. Moreover, we investigated the value of the DLRN in survival analysis.
The DLRN showed good discrimination of the number of LNM on all cohorts overall C-indexes (95% confidence interval): 0.821 (0.785–0.858) in the primary cohort, 0.797 (0.771–0.823) in the external validation cohorts, and 0.822 (0.756–0.887) in the international validation cohort. The nomogram performed significantly better than the routinely used clinical N stages, tumor size, and clinical model (P < 0.05). Besides, DLRN was significantly associated with the overall survival of LAGC patients (n = 271).
A deep learning-based radiomic nomogram had good predictive value for LNM in LAGC. In staging-oriented treatment of gastric cancer, this preoperative nomogram could provide baseline information for individual treatment of LAGC.
•Evaluation of the lymph node metastasis (LNM) is the basis of individual treatment of locally advanced gastric cancer (LAGC).•Deep leaning radiomic nomogram (DLRN) based on CT images can preoperatively determine the number of LNM in LAGC.•DLRN is significantly superior to the routinely used clinical N stages, tumor size, and clinical model.•DLRN is significantly associated with the overall survival of LAGC.
A general feature of unconventional superconductors is the existence of a superconducting dome in the phase diagram. Here we report a series of discrete superconducting phases in the simplest ...iron-based superconductor, FeSe thin flakes, by continuously tuning the carrier concentration through the intercalation of Li and Na ions with a solid ionic gating technique. Such discrete superconducting phases are robust against the substitution of 20% S for Se, but they are vulnerable to the substitution of 2% Cu for Fe, highlighting the importance of the iron site being intact. The superconducting phase diagram for FeSe derivatives is given, which is distinct from that of other unconventional superconductors.
We report constraints on the dark photon effective kinetic mixing parameter (κ) with data taken from two p-type point-contact germanium detectors of the CDEX-10 experiment at the China Jinping ...Underground Laboratory. The 90% confidence level upper limits on κ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (m_{V}) from 10 to 300 eV/c^{2} in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90% confidence level with m_{V} from 0.1 to 4.0 keV/c^{2} are set from 449.6 kg-day data, with a minimum of κ=1.3×10^{-15} at m_{V}=200 eV/c^{2}.