Backward-angle meson electroproduction above the resonance region, which was previously ignored, is anticipated to offer unique access to the three quark plus sea component of the nucleon wave ...function. In this Letter, we present the first complete separation of the four electromagnetic structure functions above the resonance region in exclusive ω electroproduction off the proton, ep→e′pω, at central Q2 values of 1.60, 2.45 GeV2, at W=2.21 GeV. The results of our pioneering −u≈−umin study demonstrate the existence of a unanticipated backward-angle cross section peak and the feasibility of full L/T/LT/TT separations in this never explored kinematic territory. At Q2=2.45 GeV2, the observed dominance of σT over σL, is qualitatively consistent with the collinear QCD description in the near-backward regime, in which the scattering amplitude factorizes into a hard subprocess amplitude and baryon to meson transition distribution amplitudes: universal nonperturbative objects only accessible through backward-angle kinematics.
The 1H(e,e'pi+)n cross section was measured at four-momentum transfers of Q2=1.60 and 2.45 GeV2 at an invariant mass of the photon nucleon system of W=2.22 GeV. The charged pion form factor (F(pi)) ...was extracted from the data by comparing the separated longitudinal pion electroproduction cross section to a Regge model prediction in which F(pi) is a free parameter. The results indicate that the pion form factor deviates from the charge-radius constrained monopole form at these values of Q2 by one sigma, but is still far from its perturbative quantum chromodynamics prediction.
Separated longitudinal and transverse structure functions for the reaction 1H(e,e(')pi(+))n were measured in the momentum transfer region Q2 = 0.6--1.6 (GeV/c)(2) at a value of the invariant mass W = ...1.95 GeV. New values for the pion charge form factor were extracted from the longitudinal cross section by using a recently developed Regge model. The results indicate that the pion form factor in this region is larger than previously assumed and is consistent with a monopole parametrization fitted to very low Q2 elastic data.
We report on the measurement of the γp→J/ψp cross section from E_{γ}=11.8 GeV down to the threshold at 8.2 GeV using a tagged photon beam with the GlueX experiment. We find that the total cross ...section falls toward the threshold less steeply than expected from two-gluon exchange models. The differential cross section dσ/dt has an exponential slope of 1.67±0.39 GeV^{-2} at 10.7 GeV average energy. The LHCb pentaquark candidates P_{c}^{+} can be produced in the s channel of this reaction. We see no evidence for them and set model-dependent upper limits on their branching fractions B(P_{c}^{+}→J/ψp) and cross sections σ(γp→P_{c}^{+})×B(P_{c}^{+}→J/ψp).
Over three quarters of a million 1-mm-diameter 4-m-long Kuraray double-clad SCSF-78MJ (blue-green) scintillating fibers have been used in the construction of the GlueX electromagnetic barrel ...calorimeter for the Hall D experimental program at Jefferson Lab. The quality of a random sample of 4750 of these fibers was evaluated by exciting the fibers at their mid point using a 90Sr source in order to determine the light yield using a calibrated vacuum photomultiplier as the photosensor. A novel methodology was developed to extract the number of photoelectrons detected for measurements where individual photoelectron peaks are not discernible. The average number of photoelectrons from this sample of fibers was 9.17±0.6 at a source distance of 200cm from the PMT.
•Extraction of number of photoelectrons from scintillating fibers readout by a calibrated PMT.•Experimental method included 90Sr source stimulating the fibers.•Analysis method accounts for broadening of spectra due to energy deposition and photo statistics.•Npe extraction method was developed for measurements where individual photo peaks are not visible in the acquired spectra.
Silicon photomultiplier devices (SiPM) were investigated as a possible front-end detector system for the electromagnetic barrel calorimeter of the GlueX Project at Jefferson Laboratory, USA, and ...compared against a traditional 2 in vacuum photomultiplier tube. The SiPM has gain and timing resolution comparable to that of a PMT, requires a simple electronic circuit and is not sensitive to magnetic fields. These attributes allow us to conclude that it is feasible to use the SiPM as a front-end detector for this calorimeter.
Over three quarters of a million, 4-m long Kuraray double-clad SCSF-78MJ (blue–green) scintillating fibres have been used in the construction of the GlueX electromagnetic barrel calorimeter, as part ...of the Hall D experimental program at Jefferson Lab. The response and quality of a random sample of 4750 of these fibres have been evaluated by employing a 373-nm UV LED to stimulate the fibres along their length and reading out the light using a spectrophotometer and a photodiode in order to extract the spectral response and the attenuation length, respectively. Single exponential fits to the spectral response in the 100–280cm distance from the light source yielded an average bulk attenuation length and standard deviation of (387±26)cm. Double-exponential fits to the spectral response over the entire 4-m length also allowed the extraction of long and short wavelength components at (486±54)cm and (75±22)cm, respectively. Finally, diameter uniformity measurements were carried out. The quality assurance results confirmed that the fibres were of high quality and complied with GlueX specifications.
The GlueX beamline and detector Akondi, C.S.; Barbosa, F.; Barsotti, R. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
01/2021, Letnik:
987
Journal Article
Recenzirano
Odprti dostop
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a ...scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 μs. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
Relative gain monitoring of the GlueX calorimeters Anassontzis, E.G.; Ioannou, P.; Kourkoumelis, C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2014, Letnik:
738
Journal Article
Recenzirano
The relative gain of the photodetectors for the GlueX Barrel and Forward calorimeters will be monitored using modular LED driver systems. The BCAL system consists of a global controller that feeds ...power, bias voltage and trigger signals to 96 local controllers situated at the ends of the 48 BCAL modules, which drive 40 LEDs associated with the 40 light guides at the end of each module. The FCAL system consists also of a global controller, a local controller for each acrylic quadrant covering the face of the FCAL, and ten 4-LED pulser boards per local controller connected in a star configuration along the edges of the acrylic panes. The respective systems are currently being installed on the detectors and their tested performance is presented herein.
•Electromagnetic calorimeter relative gain monitoring.•LED-based pulser system using common triggering.•Robust, cost effective, redundant operation.•System will measure radiation damage in lead glass.