During the second long shutdown (LS2) of the CERN Large Hadron Collider (LHC), the Detector Control System (DCS) of the Compact Muon Solenoid (CMS) Electromagnetic Calorimeter (ECAL) is undergoing a ...large software upgrade at various levels. The ECAL DCS supervisory system has been reviewed and extended to migrate the underlying software toolkits and platform technologies to the latest versions. The resulting software will run on top of a new computing infrastructure, using the WinCC Open Architecture (OA) version 3.16 and newly developed communication drivers for some of the hardware. The ECAL DCS has been configured and managed from a different control version system and stored with more modern encoding and file formats. A new set of development guidelines has been prepared for this purpose, including conventions and recommendations from the CMS Central DCS and CERN Joint Controls Project (JCOP) framework groups. The large list of modifications also motivated the revision and reorganization of the software architecture, which is needed to resolve and satisfy additional software dependencies. Many modifications also aimed to improve the installation process, anticipating in some cases works for the next long shutdown upgrade.
The AX-PET demonstrator—Design, construction and characterization Beltrame, P.; Bolle, E.; Braem, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2011, Letnik:
654, Številka:
1
Journal Article
Recenzirano
Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained ...from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100
mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end electronics and recorded in coincidence by a VME-based data acquisition system. Measurements with point-like
22Na sources, with the modules used both individually and in coincidence mode, allowed for a complete performance evaluation up to the focal plane reconstruction of point sources. The results obtained are in good agreement with expectations and proved the set-up to be ready for the next evaluation phase with PET phantoms filled with radiotracers.
The Electromagnetic Calorimeter (ECAL) is one of the subdetectors of the Compact Muon Solenoid (CMS), a general-purpose particle detector at the CERN Large Hadron Collider (LHC). The CMS ECAL ...Detector Control System (DCS) and the CMS ECAL Safety System (ESS) have supported the detector operations and ensured the detector’s integrity since the CMS commissioning phase, more than 10 years ago. Over this long period, several changes to both systems were necessary to correct issues, extend functionality and keep them in-line with current hardware technologies and the evolution of software platforms. Due to the constraints imposed on significant changes to a running system, major hardware and software upgrades were therefore deferred to the second LHC Long Shutdown (LS2). This paper presents the architectures of the CMS ECAL control and safety systems, discusses the ongoing and planned upgrades, details implementation processes and validation methods and highlights the expectations for the post-LS2 systems.