The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a ...xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6 x 10-46 cm2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4 x 104 kg ∙ day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a ...xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6 x 10-46 cm2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4 x 104 kg ∙ day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. ...Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. We follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. ...Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. Here, we follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. ...Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. Here, we follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.
OBJECTIVE: To compare synchronized intermittent mandatory ventilation (SIMV) and conventional intermittent mandatory ventilation (IMV) in neonates.
STUDY DESIGN: Prospective, multicenter, randomized ...clinical trial.
SETTING: Level III neonatal intensive care units at six university or children's hospitals.
PATIENTS: Three hundred twenty-seven infants receiving conventional IMV for respiratory distress syndrome, pneumonia, or meconium aspiration pneumonitis were randomly assigned at 7.5 ± 6 hours of age to either continue with IMV or change to SIMV. Infants assigned to each mode of ventilation had similar birth weight (BW), gestational age, and Apgar scores at birth, and similar oxygenation indexes at randomization. They received similar surfactant therapy and had similar incidence of sepsis, seizures, secondary pneumonia, and necrotizing enterocolitis. In the infants with BW less than 1000 gm, more infants receiving IMV had surgical ligation of their patent ductus arteriosus than did those receiving SIMV (27 vs 7%;
p = 0.02).
ANALYSIS: Data was analyzed overall for all infants and also separately within three BW groups: less than 1000 gm, 1000 to 2000 gm, and more than 2000 gm. The 1000 to 2000 gm BW group was further analyzed in subgroups weighing 1000 to 1499 gm and 1500 to 2000 gm.
RESULTS: In all infants, at 1 hour after randomization, the infants receiving SIMV had a lower mean airway pressure than those receiving IMV (8.08 ± 2.15 vs 8.63 ± 2.59;
p <0.05), with similar fractions of inspired oxygen and oxygenation indexes. Infants whose BW was 1000 to 2000 gm at 0.5 hour required a lower fraction of inspired oxygen with SIMV than with IMV (0.52 ± 0.20 vs 0.62 ± 0.27;
p <0.05) and had better oxygenation at 1 hour, as shown by lower oxygenation indexes with SIMV than with IMV (6.14 ± 4.17 vs 9.42 ± 8.41;
p = 0.01). Infants whose BW was 1000 to 2000 gm received a lower number of unit doses of sedative/analgesic drugs per infant during the first 4 days of SIMV than did infants receiving IMV (3.8 ± 3.4 vs 6.3 ± 5.5 unit doses;
p = 0.02). Infants whose BW was more than 2000 gm had a shorter duration of mechanical ventilation with SIMV than with IMV (median, 72 vs 93 hours;
p = 0.02). Three of the forty-six infants receiving IMV but none of the 47 infants receiving SIMV required extracorporeal membrane oxygenation. In the infants with BW less than 1000 gm, fewer infants treated with SIMV required supplemental oxygen at 36 weeks of postconceptional age than did those treated with IMV (47 vs 72%;
p <0.05). In 83 infants whose lungs were mechanically ventilated for 14 days or longer, all with BW less than 2000 gm, those treated with SIMV regained their BW earlier than those treated with IMV (median, 21.5 vs 29 days;
p <0.01). There were no differences in the rates of death, intraventricular hemorrhage (grades III and IV), air leak, need for pharmacologic paralysis, or need for supplemental oxygen at 28 days.
CONCLUSIONS: We found that SIMV was at least as efficacious as conventional IMV, and may have improved certain outcomes in BW-specific groups. (J P
EDIATR 1996;128:453-63)
The aim of this study was to quantify the global prevalence of chronic obstructive pulmonary disease (COPD) by means of a systematic review and random effects meta-analysis. PubMed was searched for ...population-based prevalence estimates published during the period 1990-2004. Articles were included if they: 1) provided total population or sex-specific estimates for COPD, chronic bronchitis and/or emphysema; and 2) gave method details sufficiently clearly to establish the sampling strategy, approach to diagnosis and diagnostic criteria. Of 67 accepted articles, 62 unique entries yielded 101 overall prevalence estimates from 28 different counties. The pooled prevalence of COPD was 7.6% from 37 studies, of chronic bronchitis alone (38 studies) was 6.4% and of emphysema alone (eight studies) was 1.8%. The pooled prevalence from 26 spirometric estimates was 8.9%. The most common spirometric definitions used were those of the Global Initiative for Chronic Obstructive Lung Disease (13 estimates). There was significant heterogeneity, which was incompletely explained by subgroup analysis (e.g. age and smoking status). The prevalence of physiologically defined chronic obstructive pulmonary disease in adults aged > or =40 yrs is approximately 9-10%. There are important regional gaps, and methodological differences hinder interpretation of the available data. The efforts of the Global Initiative for Chronic Obstructive Lung Disease and similar groups should help to standardise chronic obstructive pulmonary disease prevalence measurement.
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background ...negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. Here, we characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying the background under different experimental conditions, we identified the leading emission mechanisms, including photoionization and the photoelectric effect induced by the xenon luminescence, delayed emission of electrons trapped under the liquid surface, capture and release of drifting electrons by impurities, and grid electron emission. We discuss how these backgrounds can be mitigated in LUX and future xenon-based dark matter experiments.