An intense positron sources is a demanding element in the design of future lepton colliders. A crystal-based hybrid positron source could be an alternative to a more conventional scheme based on the ...electron conversion into positron in a thick amorphous target. The conceptual idea of the hybrid source is to have two separate objects, a photon radiator and a photon-to-positron converter target. In such a scheme an electron beam crosses a thin axially oriented crystal with the emission of a channeling radiation, characterized by a considerably larger amount of photons if compared to Bremsstrahlung. The net result is an increase in the number of produced positrons at the converter target. In this paper we present the results of a beam test conducted at the DESY TB 21 with 5.6 GeV electron beam and a crystalline tungsten radiator. Experimental data clearly highlight an increased production of photons and they are critically compared with the outcomes of novel method to simulate the number of radiated photons, showing a very good agreement. Strong of this, the developed simulation tool has been exploited to design a simple scheme for a positron source based on oriented crystal, demonstrating the advantages in terms of reduction of both deposited energy and the peak energy deposition density if compared to conventional sources. The presented work opens the way for a realistic and detailed design of a hybrid crystal-based positron source for future lepton colliders.
Antihydrogen, a positron bound to an antiproton, is the simplest antiatom. Its counterpart-hydrogen--is one of the most precisely investigated and best understood systems in physics research. ...High-resolution comparisons of both systems provide sensitive tests of CPT symmetry, which is the most fundamental symmetry in the Standard Model of elementary particle physics. Any measured difference would point to CPT violation and thus to new physics. Here we report the development of an antihydrogen source using a cusp trap for in-flight spectroscopy. A total of 80 antihydrogen atoms are unambiguously detected 2.7 m downstream of the production region, where perturbing residual magnetic fields are small. This is a major step towards precision spectroscopy of the ground-state hyperfine splitting of antihydrogen using Rabi-like beam spectroscopy.
Electromagnetic dipole moments of short-lived particles are sensitive to physics within and beyond the Standard Model of particle physics but have not been accessible experimentally to date. To ...perform such measurements it has been proposed to exploit the spin precession of channeled particles in bent crystals at the LHC. Progress that enables the first measurement of charm baryon dipole moments is reported. In particular, the design and characterization on beam of silicon and germanium bent crystal prototypes, the optimization of the experimental setup, and advanced analysis techniques are discussed. Sensitivity studies show that first measurements of Λc+ and Ξc+ baryon dipole moments can be performed in two years of data taking with an experimental setup positioned upstream of the LHCb detector.
We report on the measurements of the spectra of gamma radiation generated by 855 MeV electrons in bent silicon and germanium crystals at MAMI (MAinzer MIkrotron). The crystals were 15
μ
m
thick ...along the beam direction to ensure high deflection efficiency. Their (111) crystalline planes were bent by means of a piezo-actuated mechanical holder, which allowed to remotely change the crystal curvature. In such a way it was possible to investigate the radiation emitted under planar channeling and volume reflection as a function of the curvature of the crystalline planes. We showed that, using volume reflection, intense gamma radiation can be produced – with intensity comparable to that obtained in channeling but with higher angular acceptance. We studied the trade-off between radiation intensity and angular acceptance at different values of the crystal curvature. The measurements of radiation spectra have been carried out for the first time in bent germanium crystals. In particular, the intensity of radiation in the germanium crystal is higher than in the silicon one due to the higher atomic number, which is important for the development of the X-ray and gamma radiation sources based on higher-Z deformed crystals, such as crystalline undulators.
The ASACUSA antihydrogen and hydrogen program: results and prospects Malbrunot, C.; Amsler, C.; Arguedas Cuendis, S. ...
Philosophical transactions - Royal Society. Mathematical, Physical and engineering sciences/Philosophical transactions - Royal Society. Mathematical, physical and engineering sciences,
03/2018, Letnik:
376, Številka:
2116
Journal Article
Recenzirano
Odprti dostop
The goal of the ASACUSA-CUSP collaboration at the Antiproton Decelerator of CERN is to measure the ground-state hyperfine splitting of antihydrogen using an atomic spectroscopy beamline. A milestone ...was achieved in 2012 through the detection of 80 antihydrogen atoms 2.7 m away from their production region. This was the first observation of 'cold' antihydrogen in a magnetic field free region. In parallel to the progress on the antihydrogen production, the spectroscopy beamline was tested with a source of hydrogen. This led to a measurement at a relative precision of 2.7×10−9 which constitutes the most precise measurement of the hydrogen hyperfine splitting in a beam. Further measurements with an upgraded hydrogen apparatus are motivated by CPT and Lorentz violation tests in the framework of the Standard Model Extension. Unlike for hydrogen, the antihydrogen experiment is complicated by the difficulty of synthesizing enough cold antiatoms in the ground state. The first antihydrogen quantum states scan at the entrance of the spectroscopy apparatus was realized in 2016 and is presented here. The prospects for a ppm measurement are also discussed.
This article is part of the Theo Murphy meeting issue 'Antiproton physics in the ELENA era'.
We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the sample was not ...aligned with the beam direction. This enhancement resulted from the interaction of particles with the strong crystalline electromagnetic field. The data collected at the external lines of the CERN Super Proton Synchrotron were critically compared to Monte Carlo simulations based on the Baier-Katkov quasiclassical method, highlighting a reduction of the scintillator radiation length by a factor of 5 in the case of beam alignment with the 001 crystal axes. The observed effect opens the way to the realization of compact electromagnetic calorimeters or detectors based on oriented scintillator crystals in which the amount of material can be strongly reduced with respect to the state of the art. These devices could have relevant applications in fixed-target experiments, as well as in satellite-borne γ telescopes.
We have observed a significant enhancement in the energy deposition by 25–
100
GeV
photons in a
1
cm
thick tungsten crystal oriented along its
⟨
111
⟩
lattice axes. At
100
GeV
, this enhancement, ...with respect to the value observed without axial alignment, is more than twofold. This effect, together with the measured huge increase in secondary particle generation is ascribed to the acceleration of the electromagnetic shower development by the strong axial electric field. The experimental results have been critically compared with a newly developed Monte Carlo adapted for use with crystals of multi-
X
0
thickness. The results presented in this paper may prove to be of significant interest for the development of high-performance photon absorbers and highly compact electromagnetic calorimeters and beam dumps for use at the energy and intensity frontiers.
We observed reduction of multiple Coulomb scattering of 855 MeV electrons within a Si crystalline plate w.r.t. an amorphous plate with the same mass thickness. The reduction owed to complete or ...partial suppression of the coherent part of multiple scattering in a crystal vs crystal orientation with the beam. Experimental data were collected at Mainz Mikrotron and critically compared to theoretical predictions and Monte Carlo simulations. Our results highlighted maximal 7% reduction of the r.m.s. scattering angle at certain beam alignment with the 100 crystal axes. However, partial reduction was recorded over a wide range of alignment of the electron beam with the crystal up to 15
∘
. This evidence may be relevant to refine the modelling of multiple scattering in crystals for currently used software, which is interesting for detectors in nuclear, medical, high energy physics.
Systematic measurements of the annihilation cross sections of low energy antinucleons were performed at CERN in the 80's and 90's. However the antiproton data on medium-heavy and heavy nuclear ...targets are scarce. The ASACUSA Collaboration at CERN has measured the antiproton annihilation cross section on carbon at 5.3 MeV: the value is (1.73 ± 0.25) barn. The result is compared with the antineutron experimental data and with the theoretical previsions.