Urban noise is one of the most serious and underestimated environmental problems. According to the World Health Organization, noise pollution from traffic and other human activities, negatively ...impact the population health and life quality. Monitoring noise usually requires the use of professional and expensive instruments, called phonometers, able to accurately measure sound pressure levels. In many cases, phonometers are human-operated; therefore, periodic fine-granularity city-wide measurements are expensive. Recent advances in the Internet of Things (IoT) offer a window of opportunities for low-cost autonomous sound pressure meters. Such devices and platforms could enable fine time–space noise measurements throughout a city. Unfortunately, low-cost sound pressure sensors are inaccurate when compared with phonometers, experiencing a high variability in the measurements. In this paper, we present RaveGuard, an unmanned noise monitoring platform that exploits artificial intelligence strategies to improve the accuracy of low-cost devices. RaveGuard was initially deployed together with a professional phonometer for over two months in downtown Bologna, Italy, with the aim of collecting a large amount of precise noise pollution samples. The resulting datasets have been instrumental in designing InspectNoise, a library that can be exploited by IoT platforms, without the need of expensive phonometers, but obtaining a similar precision. In particular, we have applied supervised learning algorithms (adequately trained with our datasets) to reduce the accuracy gap between the professional phonometer and an IoT platform equipped with low-end devices and sensors. Results show that RaveGuard, combined with the InspectNoise library, achieves a 2.24% relative error compared to professional instruments, thus enabling low-cost unmanned city-wide noise monitoring.
Several studies reported a high incidence of pulmonary embolism (PE) among patients with severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, but detailed data about clinical ...characteristics, risk factors of these patients and prognostic role of PE are still lacking. We aim to evaluate the occurrence of pulmonary embolism among patients with SARS-CoV-2 infection, and to describe their risk factors, clinical characteristics, and in-hospital clinical outcomes.
This is a multicenter Italian study including 333 consecutive SARS-CoV-2 patients admitted to seven hospitals from February 22 to May 15, 2020. All the patients underwent computed tomography pulmonary angiography (CTPA) for PE detection. In particular, CTPA was performed in case of inadequate response to high-flow oxygen therapy (Fi02≥0.4 to maintain Sp02≥92%), elevated D-dimer (>0.5μg/mL), or echocardiographic signs of right ventricular dysfunction. Clinical, laboratory and radiological data were also analyzed.
Among 333 patients with laboratory confirmed SARS-CoV-2 pneumonia and undergoing CTPA, PE was detected in 109 (33%) cases. At CTPA, subsegmental, segmental, lobar and central thrombi were detected in 31 (29%), 50 (46%), 20 (18%) and 8 (7%) cases, respectively. In-hospital death occurred in 29 (27%) patients in the PE-group and in 47 (21%) patients in the non-PE group (p = 0.25). Patients in PE-group had a low rate of traditional risk factors and deep vein thrombosis was detected in 29% of patients undergoing compression ultrasonography. In 71% of cases with documented PE, the thrombotic lesions were located in the correspondence of parenchymal consolidation areas.
Despite a low rate of risk factors for venous thromboembolism, PE is present in about 1 out 3 patients with SARS-CoV-2 pneumonia undergoing CTPA for inadequate response to oxygen therapy, elevated D-dimer level, or echocardiographic signs of right ventricular dysfunction. In most of the cases, the thromboses were located distally in the pulmonary tree and were mainly confined within pneumonia areas.
S. epidermidis is one of the leading causes of orthopaedic infections associated with biofilm formation on implant devices. Open fractures are at risk of S. epidermidis transcutaneous contamination ...leading to higher non-union development compared to closed fractures. Although the role of infection in delaying fracture healing is well recognized, no in vivo models investigated the impact of subclinical low-grade infections on bone repair and non-union. We hypothesized that the non-union rate is directly related to the load of this commonly retrieved pathogen and that a low-grade contamination delays the fracture healing without clinically detectable infection. Rat femurs were osteotomized and stabilized with plates. Fractures were infected with a characterized clinical-derived methicillin-resistant S. epidermidis (10(3), 10(5), 10(8) colony forming units) and compared to uninfected controls. After 56 days, bone healing and osteomyelitis were clinically assessed and further evaluated by micro-CT, microbiological and histological analyses. The biofilm formation was visualized by scanning electron microscopy. The control group showed no signs of infection and a complete bone healing. The 10(3) group displayed variable response to infection with a 67% of altered bone healing and positive bacterial cultures, despite no clinical signs of infection present. The 10(5) and 10(8) groups showed severe signs of osteomyelitis and a non-union rate of 83-100%, respectively. The cortical bone reaction related to the periosteal elevation in the control group and the metal scattering detected by micro-CT represented limitations of this study. Our model showed that an intra-operative low-grade S. epidermidis contamination might prevent the bone healing, even in the absence of infectious signs. Our findings also pointed out a dose-dependent effect between the S. epidermidis inoculum and non-union rate. This pilot study identifies a relevant preclinical model to assess the role of subclinical infections in orthopaedic and trauma surgery and to test specifically designed diagnostic, prevention and therapeutic strategies.
Fabry disease (FD) is a genetic lysosomal storage disease with frequent cardiovascular involvement, whose presence is a major determinant of adverse clinical outcomes. As a potentially treatable ...cause of left ventricular hypertrophy (LVH) and heart failure with preserved ejection fraction, the early recognition of FD is crucial to initiate enzyme replacement therapy and improve long-term prognosis. Multimodality imaging plays a central role in the evaluation of patients with FD and helps in the differential diagnosis of other conditions presenting with LVH. In the present review, we explore the current applications of multimodality cardiac imaging, in particular echocardiography and cardiovascular magnetic resonance, in the diagnosis, prognostic assessment, and follow-up of patients with FD.
The presence of mitral annulus disjunction (MAD) has been considered a high-risk feature for sudden cardiac death based on selected study populations. We aimed to assess the prevalence of MAD in ...consecutive patients undergoing clinically indicated cardiovascular magnetic resonance (CMR), its association with ventricular arrhythmias, mitral valve prolapse (MVP), and other CMR features.
This single-center retrospective study included consecutive patients referred to CMR at our institution between June 2021 and November 2021. MAD was defined as a ≥1 mm displacement between the left atrial wall-mitral valve leaflet junction and the left ventricular wall during end-systole. MAD extent was defined as the maximum longitudinal displacement. Associates of MAD were evaluated at univariable and multivariable regression analysis. The study endpoint, a composite of (aborted) sudden cardiac death, unexplained syncope, and sustained ventricular tachycardia, was evaluated at a 12-month follow-up.
Four hundred and forty-one patients 55 ± 18 years, 267/441 (61%) males) were included, and 29/441 (7%) had MVP. The prevalence of MAD ≥1 mm, 4 mm, and 6 mm was 214/441 (49%), 63/441 (14%), and 15/441 (3%), respectively. Patients with MVP showed a higher prevalence of MAD greater than 1 mm (26/29 (90%) vs 118/412 (46%)); p < 0.001), 4 mm (14/29 (48%) vs 49/412 (12%)); p < 0.001), and 6 mm (3/29 (10%) vs 12/412 (3%)); p = 0.03), and a greater MAD extent (4.2 mm, 3.0–5.7 mm vs 2.8 mm, 1.9–4.0 mm; p < 0.001) compared to patients without MVP. MVP was the only morpho-functional abnormality associated with MAD at multivariable analysis (p < 0.001). A high burden of ventricular ectopic beats at baseline Holter-electrocardiogram was associated with MAD ≥4 mm and MAD extent (p < 0.05). The presence of MAD ≥1 mm (0.9% vs 1.8%; p = 0.46), MAD ≥4 mm (1.6% vs 1.3%; p = 0.87), or MVP (3.5% vs 1.2%; p = 0.32) were not associated with the study endpoint, whereas patients with MAD ≥6 mm showed a trend toward a higher likelihood of the study endpoint (6.7% vs 1.2%; p = 0.07).
MAD of limited severity was common in consecutive patients undergoing CMR. Patients with MVP showed higher prevalence and greater extent of MAD. Extended MAD was rarer and showed association with ventricular arrhythmias at baseline. The mid-term prognosis of MAD seems benign; however, prospective studies are warranted to search for potential “malignant MAD extents” to improve patients’ risk stratification.
Display omitted
Hypertrophic cardiomyopathy (HCM) is a genetic cardiac disease that presents with cardiac hypertrophy. HCM phenocopies are clinical conditions that are phenotypically undistinguishable from HCM, but ...with a different underlying etiology. Cardiac tumors are rare entities that can sometimes mimic HCM in their echocardiographic appearance, thus representing an example of HCM phenocopy. At present, only case reports of tumoral HCM phenocopies can be found in literature. In this systematic review, we analyzed all the published cases in which a cardiac tumor mimicked HCM to the point of misleading the diagnosis, providing a structured overview of the currently available evidence on this topic.
Periprosthetic bacterial infections represent one of the most challenging orthopaedic complications that often require implant removal and surgical debridement and carry high social and economical ...costs. Diabetes is one of the most relevant risk factors of implant-related infection and its clinical occurrence is growing worldwide. The aim of the present study was to test a model of implant-related infection in the diabetic mouse, with a view to allow further investigation on the relative efficacy of prevention and treatment options in diabetic and non-diabetic individuals.
A cohort of diabetic NOD/ShiLtJ mice was compared with non-diabetic CD1 mice as an in vivo model of S. aureus orthopaedic infection of bone and soft tissues after femur intramedullary pin implantation. We tested control and infected groups with 1×10(3) colony-forming units of S. aureus ATCC 25923 strain injected in the implant site. At 4 weeks post-inoculation, host response to infection, microbial biofilm formation, and bone damage were assessed by traditional diagnostic parameters (bacterial culture, C-reactive protein and white blood cell count), histological analysis and imaging techniques (micro computed tomography and scanning electron microscopy).
Unlike the controls and the CD1 mice, all the diabetic mice challenged with a single inoculum of S. aureus displayed severe osteomyelitic changes around the implant.
Our findings demonstrate for the first time that the diabetic mouse can be successfully used in a model of orthopaedic implant-related infection. Furthermore, the same bacteria inoculum induced periprosthetic infection in all the diabetic mice but not in the controls. This animal model of implant-related infection in diabetes may be a useful tool to test in vivo treatments in diabetic and non-diabetic individuals.
Transfemoral aortic valve implantation (TAVI) has been long considered the standard of therapy for high-risk patients with severe aortic-stenosis and is now effectively employed in place of surgical ...aortic valve replacement also in intermediate-risk patients. The potential lasting consequences of minor complications, which might have limited impact on elderly patients, could be more noteworthy in the longer term when occurring in younger individuals. That’s why a greater focus on early diagnosis, correct management, and prevention of post-procedural complications is key to achieve satisfactory results. ECG-triggered multidetector computed tomography angiography (CTA) is the mainstay imaging modality for pre-procedural planning of TAVI and is also used for post-interventional early detection of both acute and long-term complications. CTA allows detailed morphological analysis of the valve and its movement throughout the entire cardiac cycle. Moreover, stent position, coronary artery branches, and integrity of the aortic root can be precisely evaluated. Imaging reliability implies the correct technical setting of the computed tomography scan, knowledge of valve type, normal post-interventional findings, and awareness of classic and life-threatening complications after a TAVI procedure. This educational review discusses the main post-procedural complications of TAVI with a specific imaging focus, trying to clearly describe the technical aspects of CTA Imaging in post-TAVI and its clinical applications and challenges, with a final focus on future perspectives and emerging technologies.
Critical relevance statement
This review undertakes an analysis of the role computed tomography angiography (CTA) plays in the assessment of post-TAVI complications. Highlighting the educational issues related to the topic, empowers radiologists to refine their clinical approach, contributing to enhanced patient care.
Key Points
Prompt recognition of TAVI complications, ranging from value issues to death, is crucial.
Adherence to recommended scanning protocols, and the optimization of tailored protocols, is essential.
CTA is central in the diagnosis of TAVI complications and functions as a gatekeeper to treatment.
Graphical Abstract
Risk stratification for malignant ventricular arrhythmias and sudden cardiac death is a daunting task for physicians in daily practice. Multiparametric mapping sequences obtained via cardiovascular ...magnetic resonance imaging can improve the risk stratification for malignant ventricular arrhythmias by unveiling the presence of pathophysiological pro-arrhythmogenic processes. However, their employment in clinical practice is still restricted. The present review explores the current evidence supporting the association between mapping abnormalities and the risk of ventricular arrhythmias in several cardiovascular diseases. The key message is that further clinical studies are needed to test the additional value of mapping techniques beyond conventional cardiovascular magnetic resonance imaging for selecting patients eligible for an implantable cardioverter defibrillator.