Bioinorganic chemistry is critical to cellular function. Homeostasis of manganese (Mn), for example, is essential for life. A lack of methods for direct in situ visualization of Mn and other ...biological metals within intact multicellular eukaryotes limits our understanding of management of these metals. We provide the first quantitative subcellular visualization of endogenous Mn concentrations (spanning two orders of magnitude) associated with individual cells of the nematode, Caenorhabditis elegans.
The usefulness of zinc oxide (ZnO) nanoparticles has led to their wide distribution in consumer products, despite only a limited understanding of how this nanomaterial behaves within biological ...systems. From a nanotoxicological viewpoint the interaction(s) of ZnO nanoparticles with cells of the immune system is of specific interest, as these nanostructures are readily phagocytosed. In this study, rapid scanning X-ray fluorescence microscopy was used to assay the number ZnO nanoparticles associated with ∼1000 individual THP-1 monocyte-derived human macrophages. These data showed that nanoparticle-treated cells endured a 400% elevation in total Zn levels, 13-fold greater than the increase observed when incubated in the presence of an equitoxic concentration of ZnCl2. Even after excluding the contribution of internalized nanoparticles, Zn levels in nanoparticle treated cells were raised ∼200% above basal levels. As dissolution of ZnO nanoparticles is critical to their cytotoxic response, we utilized a strategy combining ion beam milling, X-ray fluorescence and scanning electron microscopy to directly probe the distribution and composition of ZnO nanoparticles throughout the cellular interior. This study demonstrated that correlative photon and ion beam imaging techniques can provide both high-resolution and statistically powerful information on the biology of metal oxide nanoparticles at the single-cell level. Our approach promises ready application to broader studies of phenomena at the interface of nanotechnology and biology.
X-ray fluorescence microscopy (XFM) facilitates high-sensitivity quantitative imaging of trace metals at high spatial resolution over large sample areas and can be applied to a diverse range of ...biological samples. Accurate determination of elemental content from recorded spectra requires proper calibration of the XFM instrument under the relevant operating conditions. Here, we describe the manufacture, characterization, and utilization of multi-element thin-film reference foils for use in calibration of XFM measurements of biological and other specimens. We have used these internal standards to assess the two-dimensional distribution of trace metals in a thin tissue section of a rat hippocampus. The data used in this study was acquired at the XFM beamline of the Australian Synchrotron using a new 384-element array detector (Maia) and at beamline 2-ID-E at the Advanced Photon Source. Post-processing of samples by different fixation techniques was investigated, with the conclusion that differences in solvent type and sample handling can significantly alter elemental content. The present study highlights the quantitative capability, high statistical power, and versatility of the XFM technique for mapping trace metals in biological samples, e.g., brain tissue samples in order to help understand neurological processes, especially when implemented in conjunction with a high-performance detector such as Maia.
The endcaps of the ATLAS Semiconductor Tracker will be composed of about 2000 detector modules of three different layouts. Up to four single-sided sensors are glued back-to-back with a small stereo ...angle to form double-sided modules. Five different wedge shaped sensor designs are needed, with a strip pitch varying in the range from 55 to
95
μm
. The sensors are read out by a copper/Kapton multilayer hybrid which carries 12 binary read-out ASICs and all components for the optical transmission of commands and data. Within the tight constraints imposed by the need for radiation hardness, high rate capability, low mass, low cost and overlap between neighbouring modules for detector hermiticity the design has been optimised for a thermal split between the read-out chips and the silicon sensors. The performance of prototype modules stand-alone, in multi-module system tests and in the testbeam will be shown.
Laser tests of silicon detectors Doležal, Zdeněk; Escobar, Carlos; Gadomski, Szymon ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2007, Letnik:
573, Številka:
1
Journal Article
Recenzirano
This paper collects experiences from the development of a silicon sensor laser testing setup and from tests of silicon strip modules (ATLAS End-cap SCT), pixel modules (DEPFET) and large-area diodes ...using semiconductor lasers. Lasers of 1060 and 680
nm wavelengths were used. A sophisticated method of focusing the laser was developed. Timing and interstrip properties of modules were measured. Analysis of optical effects involved and detailed discussion about the usability of laser testing for particle detectors are presented.
A search for the Standard Model Higgs boson in proton–proton collisions with the ATLAS detector at the LHC is presented. The datasets used correspond to integrated luminosities of approximately 4.8 ...fb−1 collected at s=7 TeV in 2011 and 5.8 fb−1 at s=8 TeV in 2012. Individual searches in the channels H→ZZ(⁎)→4ℓ, H→γγ and H→WW(⁎)→eνμν in the 8 TeV data are combined with previously published results of searches for H→ZZ(⁎), WW(⁎), bb¯ and τ+τ− in the 7 TeV data and results from improved analyses of the H→ZZ(⁎)→4ℓ and H→γγ channels in the 7 TeV data. Clear evidence for the production of a neutral boson with a measured mass of 126.0±0.4(stat)±0.4(sys) GeV is presented. This observation, which has a significance of 5.9 standard deviations, corresponding to a background fluctuation probability of 1.7×10−9, is compatible with the production and decay of the Standard Model Higgs boson.
Detailed measurements of the electron performance of the ATLAS detector at the LHC are reported, using decays of the
Z
,
W
and
J
/
ψ
particles. Data collected in 2010 at
are used, corresponding to an ...integrated luminosity of almost 40 pb
−1
. The inter-alignment of the inner detector and the electromagnetic calorimeter, the determination of the electron energy scale and resolution, and the performance in terms of response uniformity and linearity are discussed. The electron identification, reconstruction and trigger efficiencies, as well as the charge misidentification probability, are also presented.