Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after ...transcatheter aortic valve implantation on late outcomes in a large cohort of patients.
A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121).
The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.
Little evidence exists of the burden and predictors of cardiac death after transcatheter aortic valve replacement (TAVR).
The purpose of this study was to assess the incidence and predictors of ...cardiac death from advanced heart failure (HF) and sudden cardiac death (SCD) in a large patient cohort undergoing TAVR.
The study included a total of 3,726 patients who underwent TAVR using balloon (57%) or self-expandable (43%) valves. Causes of death were defined according to the Valve Academic Research Consortium-2.
At a mean follow-up of 22 ± 18 months, 155 patients had died due to advanced HF (15.2% of total deaths, 46.1% of deaths from cardiac causes) and 57 had died due to SCD (5.6% of deaths, 16.9% of cardiac deaths). Baseline comorbidities (chronic obstructive pulmonary disease, atrial fibrillation, left ventricular ejection fraction ≤40%, lower mean transaortic gradient, pulmonary artery systolic pressure >60 mm Hg; p < 0.05 for all) and 2 procedural factors (transapical approach, hazard ratio HR: 2.38, 95% confidence interval CI: 1.60 to 3.54; p < 0.001; presence of moderate or severe aortic regurgitation after TAVR, HR: 2.79, 95% CI: 1.82 to 4.27; p < 0.001) independently predicted death from advanced HF. Left ventricular ejection fraction ≤40% (HR: 1.93, 95% CI: 1.05 to 3.55; p = 0.033) and new-onset persistent left bundle-branch block following TAVR (HR: 2.26, 95% CI: 1.23 to 4.14; p = 0.009) were independently associated with an increased risk of SCD. Patients with new-onset persistent left bundle-branch block and a QRS duration >160 ms had a greater SCD risk (HR: 4.78, 95% CI: 1.56 to 14.63; p = 0.006).
Advanced HF and SCD accounted for two-thirds of cardiac deaths in patients after TAVR. Potentially modifiable or treatable factors leading to increased risk of mortality for HF and SCD were identified. Future studies should determine whether targeting these factors decreases the risk of cardiac death.
Abstract
Aims
The aim of this study was to compare clinical outcomes of patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with balloon-expandable (BE) valves vs. ...self-expandable (SE) valves. Transcatheter aortic valve implantation is a minimally invasive and lifesaving treatment in patients with aortic valve stenosis. Even though BE-valves and SE-valves are both commonly used on a large scale, adequately sized trials comparing clinical outcomes in patients with severe aortic valve stenosis treated with BE-valves compared with SE-valves are lacking.
Methods and results
In this CENTER-collaboration, data from 10 registries or clinical trials, selected through a systematic search, were pooled and analysed. Propensity score methodology was used to reduce treatment selection bias and potential confounding. The primary endpoints were mortality and stroke at 30 days follow-up in patients treated with BE-valves compared with SE-valves. Secondary endpoints included clinical outcomes, e.g. bleeding during hospital admission. All outcomes were split for early-generation BE-valves compared with early-generation SE-valves and new-generation BE-valves with new-generation SE-valves. The overall patient population (N = 12 381) included 6239 patients undergoing TAVI with BE-valves and 6142 patients with SE-valves. The propensity matched population had a mean age of 81 ± 7 years and a median STS-PROM score or 6.5% interquartile range (IQR) 4.0–13.0%. At 30-day follow-up, the mortality rate was not statistically different in patients undergoing TAVI with BE-valves compared with SE-valves BE: 5.3% vs. SE: 6.2%, relative risk (RR) 0.9; 95% confidence interval (CI) 0.7–1.0, P = 0.10. Stroke occurred less frequently in patients treated with BE-valves (BE: 1.9% vs. SE: 2.6%, RR 0.7; 95% CI 0.5–1.0, P = 0.03). Also, patients treated with BE-valves had a three-fold lower risk of requiring pacemaker implantation (BE: 7.8% vs. SE: 20.3%, RR 0.4; 95% CI 0.3–0.4, P < 0.001). In contrast, patients treated with new-generation BE-valves more frequently experienced major and life-threatening bleedings compared with new-generation SE-valves (BE: 4.8% vs. SE: 2.1%, RR 2.3; 95% CI 1.6–3.3, P < 0.001).
Conclusion
In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.
Fingolimod is an immunomodulatory sphingosine-1-phosphate (S1P) analogue approved for the treatment of relapsing-remitting multiple sclerosis (RRMS). The identification of biomarkers of clinical ...responses to fingolimod is a major necessity in MS to identify optimal responders and avoid the risk of disease progression in non-responders. With this aim, we used RNA sequencing to study the transcriptomic changes induced by fingolimod in peripheral blood mononuclear cells of MS-treated patients and their association with clinical response. Samples were obtained from 10 RRMS patients (five responders and five non-responders) at baseline and at 12 months of fingolimod therapy. Fingolimod exerted a vast impact at the transcriptional level, identifying 7155 differentially expressed genes (DEGs) compared to baseline that affected the regulation of numerous signaling pathways. These DEGs were predominantly immune related, including genes associated with S1P metabolism, cytokines, lymphocyte trafficking, master transcription factors of lymphocyte functions and the NF-kB pathway. Responder and non-responder patients exhibited a differential transcriptomic regulation during treatment, with responders presenting a higher number of DEGs (6405) compared to non-responders (2653). The S1P, NF-kB and TCR signaling pathways were differentially modulated in responder and non-responder patients. These transcriptomic differences offer the potential of being exploited as biomarkers of a clinical response to fingolimod.
Objectives The purpose of this study was to evaluate the need for a permanent pacemaker after transcatheter aortic valve implantation with the CoreValve prosthesis (Medtronic, Inc., Minneapolis, ...Minnesota) using the new Accutrak delivery system (Medtronic, Inc.). Background The need for a permanent pacemaker is a recognized complication after transcatheter aortic valve implantation with the CoreValve prosthesis. Methods Between April 23, 2008 and May 31, 2011, 195 consecutive patients with symptomatic aortic valve stenosis underwent transcatheter aortic valve implantation using the self-expanding CoreValve prosthesis. In 124 patients, the traditional delivery system was used, and in 71 patients, the Accutrak delivery system was used. Results There were no significant differences in baseline electrocardiographic characteristics between the traditional system and the Accutrak patients: PR interval: 153 ± 46 mm versus 165 ± 30 mm, p = 0.12; left bundle branch block: 22 (20.2%) versus 8 (12.7%), p = 0.21; right bundle branch block: 21 (19.3%) versus 8 (12.7%), p = 0.26. The depth of the prosthesis in the left ventricular outflow tract was greater with the traditional system than with the Accutrak system (9.6 ± 3.2 mm vs. 6.4 ± 3 mm, p < 0.001) and the need for a permanent pacemaker was higher with traditional system than with Accutrak (35.1% vs. 14.3%, p = 0.003). The predictors of the need for a pacemaker were the depth of the prosthesis in the left ventricular outflow tract (hazard ratio HR: 1.2, 95% confidence interval CI: 1.08 to 1.34, p < 0.001), pre-existing right bundle branch block (HR: 3.5, 95% CI: 1.68 to 7.29, p = 0.001), and use of the traditional system (HR: 27, 95% CI: 2.81 to 257, p = 0.004). Conclusions The new Accutrak delivery system was associated with less deep prosthesis implantation in the left ventricular outflow tract, which could be related to the lower rate of permanent pacemaker requirement.
Few data exist on patients with low-flow, low-gradient aortic stenosis (LFLG-AS) undergoing transcatheter aortic valve replacement (TAVR). Also, very scarce data exist on the usefulness of dobutamine ...stress echocardiography (DSE) before TAVR in these patients.
The authors sought to evaluate clinical outcomes and changes in left ventricular ejection fraction (LVEF) following TAVR in patients with classical LFLG-AS.
This multicenter registry included 287 patients with LFLG-AS undergoing TAVR. DSE was performed before TAVR in 234 patients and the presence of contractile reserve was defined as an increase of ≥20% in stroke volume. Transthoracic echocardiography was repeated at hospital discharge and at 1-year follow-up. Clinical follow-up was obtained at 1 and 12 months, and yearly thereafter.
The median Society of Thoracic Surgeons score of the study population was 7.7% (interquartile range 5.3% to 12.0%), and the mean LVEF and transvalvular gradient were 30.1 ± 9.7% and 25.4 ± 6.6 mm Hg, respectively. The presence of contractile reserve was observed in 45% of patients at DSE. Mortality rates were 3.8%, 20.1%, and 32.3% at 30 days, 1 year, and 2 years, respectively. On multivariable analysis, chronic obstructive pulmonary disease (p = 0.022) and lower hemoglobin values (p < 0.001) were associated with all-cause mortality. Lower hemoglobin values (p = 0.004) and moderate-to-severe aortic regurgitation post-TAVR (p = 0.018) were predictors of the composite of mortality and rehospitalization due to heart failure. LVEF increased by 8.3% (95% confidence interval: 6% to 11%) at 1-year follow-up, and the lack of prior coronary artery bypass graft (p = 0.004), a lower LVEF at baseline (p < 0.001), and a lower stroke volume index at baseline (p = 0.019) were associated with greater increase in LVEF. The absence of contractile reserve at baseline DSE was not associated with any negative effect on clinical outcomes or LVEF changes at follow-up.
TAVR was associated with good periprocedural outcomes in patients with LFLG-AS. However, approximately one-third of LFLG-AS TAVR recipients died at 2-year follow-up, with pulmonary disease, anemia, and residual paravalvular leaks associated with poorer outcomes. LVEF improved following TAVR, but DSE failed to predict clinical outcomes or LVEF changes over time. (Multicenter Prospective Study of Low-Flow Low-Gradient Aortic Stenosis TOPAS Study; NCT01835028).
Scarce data exist on the incidence of and factors associated with valve hemodynamic deterioration (VHD) after transcatheter aortic valve replacement (TAVR).
This study sought to determine the ...incidence, timing, and predictors of VHD in a large cohort of patients undergoing TAVR.
This multicenter registry included 1,521 patients (48% male; 80 ± 7 years of age) who underwent TAVR. Mean echocardiographic follow-up was 20 ± 13 months (minimum: 6 months). Echocardiographic examinations were performed at discharge, at 6 to 12 months, and yearly thereafter. Annualized changes in mean gradient (mm Hg/year) were calculated by dividing the difference between the mean gradient at last follow-up and the gradient at discharge by the time between examinations. VHD was defined as a ≥10 mm Hg increase in transprosthetic mean gradient during follow-up compared with discharge assessment.
The overall mean annualized rate of transprosthetic gradient progression during follow-up was 0.30 ± 4.99 mm Hg/year. A total of 68 patients met criteria of VHD (incidence: 4.5% during follow-up). The absence of anticoagulation therapy at hospital discharge (p = 0.002), a valve-in-valve (TAVR in a surgical valve) procedure (p = 0.032), the use of a 23-mm valve (p = 0.016), and a greater body mass index (p = 0.001) were independent predictors of VHD.
There was a mild but significant increase in transvalvular gradients over time after TAVR. The lack of anticoagulation therapy, a valve-in-valve procedure, a greater body mass index, and the use of a 23-mm transcatheter valve were associated with higher rates of VHD post-TAVR. Further prospective studies are required to determine whether a specific antithrombotic therapy post-TAVR may reduce the risk of VHD.
Several studies have demonstrated the benefits of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis, but the presence of persistent fibrosis and myocardial hypertrophy ...has been related to worse prognosis.
The aim of this study was to explore the potential benefits of renin-angiotensin system (RAS) inhibitors on left ventricular remodeling and major clinical outcomes following successful transcatheter aortic valve replacement (TAVR).
Patients from 10 institutions with severe aortic stenosis who underwent TAVR between August 2007 and August 2017 were included. All baseline data were prospectively recorded, and pre-specified follow-up was performed. Doses and types of RAS inhibitors at discharge were recorded, and matched comparison according to their prescription at discharge was performed.
A total of 2,785 patients were included. Patients treated with RAS inhibitors (n = 1,622) presented similar surgical risk scores but a higher rate of all cardiovascular risk factors, coronary disease, and myocardial infarction. After adjustment for these baseline differences, reduction of left ventricular volumes and hypertrophy was greater and cardiovascular mortality at 3-year follow-up was lower (odds ratio: 0.59; 95% confidence interval: 0.41 to 0.87; p = 0.007) in patients treated with RAS inhibitors. Moreover, RAS inhibitors demonstrated a global cardiovascular protective effect with significantly lower rates of new-onset atrial fibrillation, cerebrovascular events, and readmissions.
Post-TAVR RAS inhibitors are associated with lower cardiac mortality at 3-year follow-up and offer a global cardiovascular protective effect that might be partially explained by a positive left ventricular remodeling. An ongoing randomized trial will help confirm these hypothesis-generating findings. (Renin-Angiotensin System Blockade Benefits in Clinical Evolution and Ventricular Remodeling After Transcatheter Aortic Valve Implantation RASTAVI; NCT03201185)
Display omitted