Summary
The present investigation was performed in a population of patients with temporomandibular disorders (TMD), and it was designed to assess the correlation between self‐reported ...questionnaire‐based bruxism diagnosis and a diagnosis based on history taking plus clinical examination. One‐hundred‐fifty‐nine patients with TMD underwent an assessment including a questionnaire investigating five bruxism‐related items (i.e. sleep grinding, sleep grinding referral by bed partner, sleep clenching, awake clenching, awake grinding) and an interview (i.e. oral history taking with specific focus on bruxism habits) plus a clinical examination to evaluate bruxism signs and symptoms. The correlation between findings of the questionnaire, viz., patients' report, and findings of the interview/oral history taking plus clinical examination, viz., clinicians' diagnosis, was assessed by means of φ coefficient. The highest correlations were achieved for the sleep grinding referral item (φ = 0·932) and for the awake clenching item (φ = 0·811), whilst lower correlation values were found for the other items (φ values ranging from 0·363 to 0·641). The percentage of disagreement between the two diagnostic approaches ranged between 1·8% and 18·2%. Within the limits of the present investigation, it can be suggested that a strong positive correlation between a self‐reported and a clinically based approach to bruxism diagnosis can be achieved as for awake clenching, whilst lower levels of correlation were detected for sleep‐time activities.
Accurate measurements of physical processes in high energy frontier experiments demand exceptional spatial, temporal, and energy precision to discern the physics behind high-energy particle jets. ...Calorimeters, like other detection systems, must be able to meet these increasingly challenging performance requirements. In the prospective TeV-scale Muon Collider, the primary hurdle in designing detectors and devising event reconstruction algorithms is the challenge posed by Beam-Induced Background (BIB). Nevertheless, it is conceivable to mitigate the impact of BIB on the Muon Collider's calorimeter by capitalizing on certain characteristics and ensuring key features such as high granularity, precise timing, longitudinal segmentation, and superior energy resolution. This is what the here described Research and Development is trying to achieve with an innovative semi-homogeneous electromagnetic calorimeter constructed from stackable and interchangeable modules composed of lead fluoride crystals (PbF2). These modules are equipped with surface-mount UV-extended Silicon Photomultipliers (SiPMs) and are collectively referred to as the Crilin calorimeter (CRystal calorImeter with Longitudinal INformation). The challenge lies in making sure this calorimeter can operate effectively within an extremely harsh radiation environment, enduring an annual neutron flux of <inline-formula> <tex-math notation="LaTeX">10^{14}~n_{1\text {MeV}}/\text {cm}^{2} </tex-math></inline-formula> and a total ionizing dose (TID) of 10 kGy. In this article, the radiation tolerance measured in several irradiation campaigns is discussed, and the timing performances during a test beam at CERN-H2 with 120-GeV electrons. Additionally, a description of the latest prototype, Proto-1, is provided together with the results of the latest low-energy beam test at the LNF beam test facility (BTF) with 450 MeV electrons.
In modern experiment, a high granularity is required in order to distinguish signal particles from background and to solve the substructures necessary for jet identification. Time of arrival ...measurements in the calorimeter could play an important role in HL-LHC, since a high number of pile-up collisions is expected, and the timing could be used to assign clusters to the corresponding interaction vertex. In a Muon Collider, the timing could be used to remove signals produced by beam-induced background, asynchronous with respect to the bunch crossing. The calorimeter energy resolution is also fundamental to measure the kinematic properties of jets: a finely segmented calorimeter design should be favored in order to solve the jet substructure. However, this contrasts with the requirement for high timing resolution even for signal events involving low energy deposits, such as in the case of high impulse muons. Our proposed design, the Crilin calorimeter, is a semi-homogeneous calorimeter based on Lead Fluoride (PbF
2
) Crystals readout by surface-mount UV-extended Silicon Photomultipliers (SiPMs). In this paper, the development of a small prototype consisting of 2 layers of 3 × 3 crystals each is reported along with the relative results.
Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-
Z
, ultra-fast crystals with UV-extended SiPM ...readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin development program, we have carried out beam tests of small (10 × 10 × 40 mm
3
) lead fluoride (PbF
2
) and ultra-fast lead tungstate (PbWO
4
, PWO-UF) crystals with 120 GeV electrons at the CERN SPS to study the light yield, timing response, and systematics of light collection with a proposed readout scheme. For a single crystal of PbF
2
, corresponding to a single Crilin cell, a time resolution of better than 25 ps is obtained for
>
3 GeV of deposited energy. For a single cell of PWO-UF, a time resolution of better than 45 ps is obtained for the same range of deposited energy. This timing performance fully satisfies the design requirements for the Muon Collider and HIKE experiments. Further optimizations of the readout scheme and crystal surface preparation are expected to bring further improvements.
Detectors for new energy frontier experiments require excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the ...beam-induced backgrounds represent the main challenge for detector design and event reconstruction. Our proposal – Crilin – consists in a semi-homogeneous Cherenkov electromagnetic calorimeter based on PbF2 crystals with surface-mount UV-extended Silicon Photomultipliers readout.
Readout studies for the HIKE main electromagnetic calorimeter Francesconi, M.; Ambrosino, F.; Antonelli, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
8/2024
Journal Article
The Mu2e experiment at Fermilab aims to search for the SM forbidden μ−→e− conversion in Al muonic atoms. The signal signature consists of 104.96 MeV electrons, identified by a straw-tube tracker and ...a crystal calorimeter, made of two annular disks. In order to calibrate the calorimeter disks with minimum ionizing particles (MIP) before the installation, we have realized a Cosmic Ray Tagger (CRT) at Laboratori Nazionali di Frascati (LNF) of INFN. The CRT consists of two planes of eight 2.5×1.5×160 cm3 plastic scintillator (EJ-200) bars, coupled to SiPMs on both edges, so as to estimate longitudinal hit positions from time differences. 3D MIP tracking is achieved by reconstructing hit positions in the two planes, placed above and below the disks, and allows to calibrate the energy response, to align the time offsets, and to study the detector performances dependence along the crystals axis.
The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in ...operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.