Triple-GEM detectors with pad readout have been employed to equip the innermost region (R1) of the first station (M1) within the Muon system of the LHCb experiment. The GEM detectors have been ...operated with an Ar/CO2/CF4 = 45/15/40 gas mixture at a gas gain of about 4000 with an average particle flux of about 250 kHz/cm2. Throughout RUN1 and RUN2, spanning approximately 440 days of colliding beams, the GEM detectors accumulated a charge of up to 0.5 C/cm2. This paper presents a comparative analysis between a global irradiation test of GEM detectors at the Calliope facility (ENEA-Casaccia, 1.25 MeV γ ray flux from a 60Co source) and the GEMs operated at LHCb, focusing on the impacts of a CF4-based gas mixture. In both instances, the detectors were opened and the GEM foils were examined by the EN-MME-MM CERN group with a Field Emission Gun Scanning Electron Microscope (FEG-SEM) for a magnified image analysis and an X-Max Energy Dispersive X-ray Spectroscopy (EDS) for the chemical one.
Tumour control is performed in particle therapy using particles and ions, whose high irradiation precision enhances the effectiveness of the treatment, while sparing the healthy tissue surrounding ...the target volume. Dose range monitoring devices using photons and charged particles produced by the beam interacting with the patient's body have already been proposed, but no attempt has been made yet to exploit the detection of the abundant neutron component. Since neutrons can release a significant dose far away from the tumour region, precise measurements of their flux, production energy and angle distributions are eagerly sought in order to improve the treatment planning system (TPS) software. It will thus be possible to predict not only the normal tissue toxicity in the target region, but also the risk of late complications in the whole body. The aforementioned issues underline the importance of an experimental effort devoted to the precise characterisation of neutron production, aimed at the measurement of their abundance, emission point and production energy. The technical challenges posed by a neutron detector aimed at high detection efficiency and good backtracking precision are addressed within the MONDO (monitor for neutron dose in hadrontherapy) project, whose main goal is to develop a tracking detector that can target fast and ultrafast neutrons. A full reconstruction of two consecutive elastic scattering interactions undergone by the neutrons inside the detector material will be used to measure their energy and direction. The preliminary results of an MC simulation performed using the FLUKA software are presented here, together with the DSiPM (digital SiPM) readout implementation. New detector readout implementations specifically tailored to the MONDO tracker are also discussed, and the neutron detection efficiency attainable with the proposed neutron tracking strategy are reported.
The MOnitor for Neutron Dose in hadrOntherapy (MONDO) project addresses the technical challenges posed by a neutron tracker detector aiming for a high detection efficiency and a good backtracking ...precision. The project aims to develop a tracking device capable of fully reconstructing the four momentum of fast and ultrafast secondary neutrons produced, e.g., in particle therapy (PT) treatments or in other physical processes. The MONDO tracker uses, as active material, squared scintillating fibers readout by dedicated CMOS-based digital single-photon avalanche diode (SPAD) array sensors. The expected light output, when operating in neutron monitoring applications, was experimentally evaluated in order to optimize the design of the MONDO detector readout. A small detector prototype (4 × 4 × 4.8 cm) has been built and tested at a test beam facility. The detection capabilities have been measured using a traditional photomultiplier (PMT) and a particle beam of 450-MeV electrons crossing a single layer of fibers. The observed number of photoelectrons in this case is (7.2 ± 1.4). A detector prototype was also tested with an SPAD-based SBAM (SPAD-Based Acquisition readout for MONDO experiment) sensor (SPADnet-I) to study the tracking performances. SBAM is a novel sensor developed to match the need of high single-photon detection efficiency and high spatial resolution and compactness. The sensor expected performance is discussed in view of an operation tailored for PT applications. In this contribution, we also report the results of a simulation performed to optimize the full MONDO detector layout.
CYGNO is a project realising a cubic meter demonstrator to study the scalability of the performance of the optical approach for the readout of large-volume, GEM-equipped TPC. This is part of the ...CYGNUS proto-collaboration which aims at constructing a network of underground observatories for directional Dark Matter search. The combined use of high-granularity sCMOS and fast sensors for reading out the light produced in GEM channels during the multiplication processes was shown to allow on one hand to reconstruct 3D direction of the tracks, offering accurate energy measurements and sensitivity to the source directionality and, on the other hand, a high particle identification capability very useful to distinguish nuclear recoils. Results of the performed R&D and future steps toward a 30-100 cubic meter experiment will be presented.
The electromagnetic performance of the RD52 fiber calorimeter Akchurin, N.; Bedeschi, F.; Cardini, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2014, Letnik:
735
Journal Article
Recenzirano
Odprti dostop
The RD52 calorimeter is an instrument intended to detect both electromagnetic and hadronic showers, as well as muons, using the dual-readout principle. Scintillation and Cherenkov light provide the ...two signals which, in combination, allow for superior hadronic performance. In this paper, we report on the electromagnetic performance of this instrument, and compare this performance with that of other calorimeters that were constructed with similar goals in mind.
The RD52 dual-readout calorimeter is a longitudinally unsegmented instrument intended for the detection of both electromagnetically and hadronically interacting particles with unprecedented ...precision. In this paper, the identification of the showering particles and, in particular, the identification of electrons and gamma s with this instrument are investigated. The techniques used for this purpose include differences in the shower development observed with scintillation light and Cherenkov radiation, the radial shower profile of the particles and the time structure (including the starting point) of the calorimeter signals. It turns out that, at 60 GeV, electrons can be correctly identified in 99.8% of the cases, by means of criteria that eliminate 99.8% of the hadrons.
The performances of an optical readout of Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages are presented. The detector is characterized by using 55Fe ...photons converting inside a 7 litre sensitive volume detector in different electric field configurations. This prototype is developed as part of the R&D for the CYGNO project for an application to direct Dark Matter search by detection of tracks of nuclear recoils in the gas within the keV energy range.