Progenitor scenarios for short gamma-ray bursts (short GRBs) include coalescenses of two neutron stars or a neutron star and black hole, which would necessarily be accompanied by the emission of ...strong gravitational waves. We present a search for these known gravitational-wave signatures in temporal and directional coincidence with 22 GRBs that had sufficient gravitational-wave data available in multiple instruments during LIGO's fifth science run, S5, and Virgo's first science run, VSR1. We find no statistically significant gravitational-wave candidates within a -5, +1) s window around the trigger time of any GRB. Using the Wilcoxon-Mann-Whitney U test, we find no evidence for an excess of weak gravitational-wave signals in our sample of GRBs. We exclude neutron star-black hole progenitors to a median 90% CL exclusion distance of 6.7 Mpc.
Display omitted
•GEISA-2015 database release: 5,059,777 entries in the line parameters sub-database.•22 molecules updated and 1 new molecule added (SO3).•HDO is given a specific identification ...code.•Important update of the IR cross-sections and aerosols sub-databases.•GEISA line parameter database reference for current or planned TIR SWIR space missions.
The GEISA database (Gestion et Etude des Informations Spectroscopiques Atmosphériques: Management and Study of Atmospheric Spectroscopic Information) has been developed and maintained by the ARA/ABC(t) group at LMD since 1974. GEISA is constantly evolving, taking into account the best available spectroscopic data. This paper presents the 2015 release of GEISA (GEISA-2015), which updates the last edition of 2011 and celebrates the 40th anniversary of the database. Significant updates and additions have been implemented in the three following independent databases of GEISA.
The “line parameters database” contains 52 molecular species (118 isotopologues) and transitions in the spectral range from 10−6 to 35,877.031cm−1, representing 5,067,351 entries, against 3,794,297 in GEISA-2011. Among the previously existing molecules, 20 molecular species have been updated. A new molecule (SO3) has been added. HDO, isotopologue of H2O, is now identified as an independent molecular species. Seven new isotopologues have been added to the GEISA-2015 database.
The “cross section sub-database” has been enriched by the addition of 43 new molecular species in its infrared part, 4 molecules (ethane, propane, acetone, acetonitrile) are also updated; they represent 3% of the update. A new section is added, in the near-infrared spectral region, involving 7 molecular species: CH3CN, CH3I, CH3O2, H2CO, HO2, HONO, NH3.
The “microphysical and optical properties of atmospheric aerosols sub-database” has been updated for the first time since 2003. It contains more than 40 species originating from NCAR and 20 from the ARIA archive of Oxford University.
As for the previous versions, this new release of GEISA and associated management software facilities are implemented and freely accessible on the AERIS/ESPRI atmospheric chemistry data center website.
The 2009 edition of the GEISA spectroscopic database Jacquinet-Husson, N.; Crepeau, L.; Armante, R. ...
Journal of quantitative spectroscopy & radiative transfer,
10/2011, Letnik:
112, Številka:
15
Journal Article
Recenzirano
The updated 2009 edition of the spectroscopic database GEISA (Gestion et Etude des Informations Spectroscopiques Atmosphériques; Management and Study of Atmospheric Spectroscopic Information) is ...described in this paper. GEISA is a computer-accessible system comprising three independent sub-databases devoted, respectively, to: line parameters, infrared and ultraviolet/visible absorption cross-sections, microphysical and optical properties of atmospheric aerosols. In this edition, 50 molecules are involved in the line parameters sub-database, including 111 isotopologues, for a total of 3,807,997 entries, in the spectral range from 10
−6 to 35,877.031
cm
−1.
The successful performances of the new generation of hyperspectral sounders depend ultimately on the accuracy to which the spectroscopic parameters of the optically active atmospheric gases are known, since they constitute an essential input to the forward radiative transfer models that are used to interpret their observations. Currently, GEISA is involved in activities related to the assessment of the capabilities of IASI (Infrared Atmospheric Sounding Interferometer;
http://smsc.cnes.fr/IASI/index.htm) on board the METOP European satellite through the GEISA/IASI database derived from GEISA. Since the Metop-A (
http://www.eumetsat.int) launch (19 October 2006), GEISA is the reference spectroscopic database for the validation of the level-1 IASI data. Also, GEISA is involved in planetary research, i.e., modeling of Titan's atmosphere, in the comparison with observations performed by Voyager, or by ground-based telescopes, and by the instruments on board the Cassini–Huygens mission.
GEISA, continuously developed and maintained at LMD (Laboratoire de Météorologie Dynamique, France) since 1976, is implemented on the IPSL/CNRS (France) “Ether” Products and Services Centre WEB site (
http://ether.ipsl.jussieu.fr), where all archived spectroscopic data can be handled through general and user friendly associated management software facilities. More than 350 researchers are registered for on line use of GEISA.
► Strong interaction with Earth's and planetary atmospheres remote sensing. ► Improvement of the quality of the direct and inverse planetary atmosphere modeling. ► Evident importance for Research in Climate and Environment.► Promotion and motivation for Research in Spectroscopy (theoretical and experimental).
Coke drums are special pressure vessels subjected to large cyclic stresses resulting from thermal distributions that are generated by coke bed interactions and random local flows through the coke bed ...and around it near the wall.1 It is vital for owners to know as much as possible about the condition of these drums to devise or update plans for operation, inspection, repair and replacement.2,3 Full-scale visual inspection, as well as localized inspections like ultrasonic (UT) and dye penetrant (PT) inside the coke drum, are time consuming, require scaffolding and may be performed only during turnarounds. The temperature distribution on the coke drum surface when peak stresses occurred in the walls will be used as primary data-in addition to pressure, hydrostatic pressure and weight-for the finite element stress analysis of the coke drum (FIG. 3). The unit has four medium-sized coke drums made of C-/Mo steel, with a diameter of 6.3 m and a height of 26 m. To solve the problem, the engineering companya entrusted with the project applied the stress assessment method based on temperature monitoring of the coke drum walls. The results highlighted the effect of the flow patterns on the coke drum structure, showing the areas subjected to higher stresses and accumulating more fatigue damage. * Based on the information gathered, proposals for the optimization of the DCU operation were made. * Considering the results of the fatigue damage assessment, the oil refinery management decided to extend the service life of the coke drum.
The HITRAN 2008 molecular spectroscopic database Rothman, L.S.; Gordon, I.E.; Barbe, A. ...
Journal of quantitative spectroscopy & radiative transfer,
06/2009, Letnik:
110, Številka:
9
Journal Article
Recenzirano
Odprti dostop
This paper describes the status of the 2008 edition of the
HITRAN molecular spectroscopic database. The new edition is the first official public release since the 2004 edition, although a number of ...crucial updates had been made available online since 2004. The
HITRAN compilation consists of several components that serve as input for radiative-transfer calculation codes: individual line parameters for the microwave through visible spectra of molecules in the gas phase; absorption cross-sections for molecules having dense spectral features, i.e. spectra in which the individual lines are not resolved; individual line parameters and absorption cross-sections for bands in the ultraviolet; refractive indices of aerosols, tables and files of general properties associated with the database; and database management software. The line-by-line portion of the database contains spectroscopic parameters for 42 molecules including many of their isotopologues.
The goal of this study was the preparation, physicochemical characterization, and microbiological evaluation of novel hydroxyapatite doped with silver/polydimethylsiloxane (Ag:HAp-PDMS) composite ...layers. In the first stage, the deposition of polydimethylsiloxane (PDMS) polymer layer on commercially pure Si disks has been produced in atmospheric pressure corona discharges. Finally, the new silver doped hydroxyapatite/polydimethylsiloxane composite layer has been obtained by the thermal evaporation technique. The Ag:HAp-PDMS composite layers were characterized by various techniques, such as Scanning Electron Microscopy (SEM), Glow Discharge Optical Emission Spectroscopy (GDOES), and X-ray photoelectron spectroscopy (XPS). The antimicrobial activity of the Ag:HAp-PDMS composite layer was assessed against Candida albicans ATCC 10231 (ATCC—American Type Culture Collection) by culture based and confirmed by SEM and Confocal Laser Scanning Microscopy (CLSM) methods. This is the first study reporting the antimicrobial effect of the Ag:HAp-PDMS composite layer, which proved to be active against Candida albicans biofilm embedded cells.
We investigate by different complementary methods the processes occurring when a polydimethylsiloxane film is used as interlayer for a silver doped hydroxyapatite coating. The X-ray diffraction and ...Fourier Transform Infrared Spectroscopy measurements show that the hydroxyapatite doped with silver is in a crystalline form and some SiO 4 4 - ions formation takes place at the surface and in the bulk of the new hydroxyapatite doped with silver/polydimethylsiloxane composite layer. The possibility of SiO 4 4 - ions incorporation in the structure of silver doped hydroxyapatite by the mechanism of SiO 4 4 - / PO 4 3 - ions substitution is analysed. The new formed silver doped hydroxyapatite/polydimethylsiloxane composite layer is compact, homogeneous, with no cracks as it was shown by Scanning Electron Microscopy and Glow Discharge Optical Emission Spectrometry.
We have analyzed 10 room temperature spectra of the fundamental band of CO and CO-air using the Voigt, speed-dependent Voigt, speed-dependent Rautian line shape models. Line positions, intensities, ...air- and self-broadening coefficients, pressure induced air- and self-shift coefficients, and line-mixing parameters have been retrieved. The CO- and N2-broadened carbon monoxide half width coefficients have been calculated using a potential energy surface based on Tipping-Herman intermolecular interaction potential and taking the electrostatic interactions into account.
The aim of this study was the evaluation of (Ca10-xAgx)(PO4)6(OH)2 nanoparticles (Ag:HAp-NPs) for their antibacterial and antifungal activity. Resistance to antimicrobial agents by pathogenic ...bacteria has emerged in the recent years as a major public health problem worldwide. In this paper, we report a comparison of the antimicrobial activity of low concentrations silver-doped hydroxyapatite nanoparticles. The silver-doped nanocrystalline hydroxyapatite powder was synthesized at 100°C in deionised water. The as-prepared Ag:Hap nanoparticles were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), FT-IR, and FT-Raman spectroscopy. X-ray diffraction (XRD) studies demonstrate that powders obtained by coprecipitation at 100°C exhibit the apatite characteristics with good crystal structure, without any new phase or impurities found. FT-IR and FT-Raman spectroscopy revealed the presence of the various vibrational modes corresponding to phosphates and hydroxyl groups and the absence of any band characteristic to silver. The specific microbiological assays demonstrated that Ag:HAp-NPs exhibited antimicrobial features, but interacted differently with the Gram-positive, Gram-negative bacterial and fungal tested strains.
Temperature dependences of pressure-broadened half-width and pressure-induced shift coefficients along with accurate positions and intensities have been determined for transitions in the 2←0 band of ...12C16O from analyzing high-resolution and high signal-to-noise spectra recorded with two different Fourier transform spectrometers. A total of 28 spectra, 16 self-broadened and 12 air-broadened, recorded using high-purity (≥99.5% 12C-enriched) CO samples and CO diluted with dry air (research grade) at different temperatures and pressures, were analyzed simultaneously to maximize the accuracy of the retrieved parameters. The sample temperatures ranged from 150 to 298K and the total pressures varied between 5 and 700Torr. A multispectrum nonlinear least squares spectrum fitting technique was used to adjust the rovibrational constants (G, B, D, etc.) and intensity parameters (including Herman–Wallis coefficients), rather than determining individual line positions and intensities. Self- and air-broadened Lorentz half-width coefficients, their temperature dependence exponents, self- and air-pressure-induced shift coefficients, their temperature dependences, self- and air- line mixing coefficients, their temperature dependences and speed dependence have been retrieved from the analysis. Speed-dependent line shapes with line mixing employing off-diagonal relaxation matrix element formalism were needed to minimize the fit residuals. This study presents a precise and complete set of spectral line parameters that consistently reproduce the spectrum of carbon monoxide over terrestrial atmospheric conditions.