We present the commissioning of the Fast Annihilation Cryogenic Tracker detector (FACT), installed around the antihydrogen production trap inside the 1T superconducting magnet of the AEgIS ...experiment. FACT is designed to detect pions originating from the annihilation of antiprotons. Its 794 scintillating fibers operate at 4K and are read out by silicon photomultipliers (MPPCs) at near room temperature. FACT provides the antiproton/antihydrogen annihilation position information with a few ns timing resolution.
We present the hardware and software developments which led to the successful operation of the detector for antihydrogen detection and the results of an antiproton-loss based efficiency assessment. The main background to the antihydrogen signal is that of the positrons impinging onto the positronium conversion target and creating a large amount of gamma rays which produce a sizeable signal in the MPPCs shortly before the antihydrogen signal is expected. We detail the characterization of this background signal and its impact on the antihydrogen detection efficiency.
The AEgIS experiment located at the Antiproton Decelerator at CERN aims to measure the gravitational fall of a cold antihydrogen pulsed beam. The precise observation of the antiatoms in the Earth ...gravitational field requires a controlled production and manipulation of antihydrogen. The neutral antimatter is obtained via a charge exchange reaction between a cold plasma of antiprotons from ELENA decelerator and a pulse of Rydberg positronium atoms. The current custom electronics designed to operate the 5 and 1 T Penning traps are going to be replaced by a control system based on the ARTIQ & Sinara open hardware and software ecosystem. This solution is present in many atomic, molecular and optical physics experiments and devices such as quantum computers. We report the status of the implementation as well as the main features of the new control system.
In this work we describe a high-resolution position-sensitive detector for positronium. The detection scheme is based on the photoionization of positronium in a magnetic field and the imaging of the ...freed positrons with a Microchannel Plate assembly. A spatial resolution of (88±5) μm on the position of the ionized positronium –in the plane perpendicular to a 1.0 T magnetic field– is obtained. The possibility to apply the detection scheme for monitoring the emission into vacuum of positronium from positron/positronium converters, imaging positronium excited to a selected state and characterizing its spatial distribution is discussed. Ways to further improve the spatial resolution of the method are presented.
The efficient production of cold antihydrogen atoms in particle traps at CERN's Antiproton Decelerator has opened up the possibility of performing direct measurements of the Earth's gravitational ...acceleration on purely antimatter bodies. The goal of the AEgIS collaboration is to measure the value of g for antimatter using a pulsed source of cold antihydrogen and a Moiré deflectometer/Talbot-Lau interferometer. The same antihydrogen beam is also very well suited to measuring precisely the ground-state hyperfine splitting of the anti-atom. The antihydrogen formation mechanism chosen by AEgIS is resonant charge exchange between cold antiprotons and Rydberg positronium. A series of technical developments regarding positrons and positronium (Ps formation in a dedicated room-temperature target, spectroscopy of the n=1-3 and n=3-15 transitions in Ps, Ps formation in a target at 10 K inside the 1 T magnetic field of the experiment) as well as antiprotons (high-efficiency trapping of , radial compression to sub-millimetre radii of mixed plasmas in 1 T field, high-efficiency transfer of to the antihydrogen production trap using an in-flight launch and recapture procedure) were successfully implemented. Two further critical steps that are germane mainly to charge exchange formation of antihydrogen-cooling of antiprotons and formation of a beam of antihydrogen-are being addressed in parallel. The coming of ELENA will allow, in the very near future, the number of trappable antiprotons to be increased by more than a factor of 50. For the antihydrogen production scheme chosen by AEgIS, this will be reflected in a corresponding increase of produced antihydrogen atoms, leading to a significant reduction of measurement times and providing a path towards high-precision measurements.
This article is part of the Theo Murphy meeting issue 'Antiproton physics in the ELENA era'.
The primary goal of the AEgIS collaboration at CERN is to measure the gravitational acceleration on neutral antimatter. Positronium (Ps), the bound state of an electron and a positron, is a suitable ...candidate for a force-sensitive inertial measurement by means of deflectometry/interferometry. In order to conduct such an experiment, the impact position and time of arrival of Ps atoms at the detector must be detected simultaneously. The detection of a low-velocity Ps beam with a spatial resolution of (88 ± 5) μm was previously demonstrated 1. Based on the methodology employed in 1 and 2, a hybrid imaging/timing detector with increased spatial resolution of about 10 μm was developed. The performance of a prototype was tested with a positron beam. The concept of the detector and first results are presented.
A powerful and robust control system is a crucial, often neglected, pillar of any modern, complex physics experiment that requires the management of a multitude of different devices and their precise ...time synchronisation. The AEḡIS collaboration presents CIRCUS, a novel, autonomous control system optimised for time-critical experiments such as those at CERN’s Antiproton Decelerator and, more broadly, in atomic and quantum physics research. Its setup is based on Sinara/ARTIQ and TALOS, integrating the ALPACA analysis pipeline, the last two developed entirely in AEḡIS. It is suitable for strict synchronicity requirements and repeatable, automated operation of experiments, culminating in autonomous parameter optimisation via feedback from real-time data analysis. CIRCUS has been successfully deployed and tested in AEḡIS; being experiment-agnostic and released open-source, other experiments can leverage its capabilities.
We characterized the pulsed Rydberg-positronium production inside the Antimatter Experiment: Gravity, Interferometry, Spectroscopy (AE¯gIS) apparatus in view of antihydrogen formation by means of a ...charge exchange reaction between cold antiprotons and slow Rydberg-positronium atoms. Velocity measurements on the positronium along two axes in a cryogenic environment (≈10K) and in 1T magnetic field were performed. The velocimetry was done by microchannel-plate (MCP) imaging of a photoionized positronium previously excited to the n=3 state. One direction of velocity was measured via Doppler scan of this n=3 line, another direction perpendicular to the former by delaying the exciting laser pulses in a time-of-flight measurement. Self-ionization in the magnetic field due to the motional Stark effect was also quantified by using the same MCP-imaging technique for Rydberg positronium with an effective principal quantum number neff ranging between 14 and 22. We conclude with a discussion about the optimization of our experimental parameters for creating Rydberg positronium in preparation for an efficient pulsed production of antihydrogen.