To compare the diagnostic performance of multidetector computed tomography (CT) and magnetic resonance (MR) imaging in patients clinically suspected of having a scaphoid fracture and who had normal ...initial radiographs, with radiographs obtained 6 weeks after trauma as the reference standard.
The ethics committee approved the study, and all patients gave written informed consent. Twenty-nine patients (17 male, 12 female; age range, 17-62 years; mean age, 34 years +/- 13) underwent multidetector CT and MR imaging within 6 days after trauma. CT data were obtained with 0.5-mm collimation. For image review, 0.7-mm-thick multiplanar reformations were performed in transverse, coronal, and sagittal planes relative to the wrist. The 1.0-T MR examination consisted of coronal and transverse short inversion time inversion-recovery, coronal and transverse T1-weighted spin-echo, and coronal volume-rendered T2-weighted gradient-echo sequences. Two radiologists analyzed the CT and MR images. A binomial test was used to evaluate the significance of the differences between MR imaging and CT in detection of scaphoid fractures and cortical involvement (P < .05).
The 6-week follow-up radiographs depicted a scaphoid fracture in 11 (38%) patients. Eight patients had a cortical fracture, while three patients had only a bandlike lucency within the trabecular portion of the scaphoid. MR imaging depicted all 11 fractures but only three corrected cortical fractures. Multidetector CT depicted all eight cortical fractures but failed to depict trabecular fractures. No false-positive fractures were seen on MR or CT images. Differences between MR imaging and CT were not significant for the detection of scaphoid fractures (P = .25) but were significant for cortical involvement (P = .03).
Multidetector CT is highly accurate in depicting occult cortical scaphoid fractures but appears inferior to MR imaging in depicting solely trabecular injury. MR imaging is inferior to multidetector CT in depicting cortical involvement.
The purpose of this study is to develop a computed tomography (CT) biomarker of emphysema that is robust across reconstruction settings, and evaluate its ability to predict mortality in patients at ...high risk for lung cancer. Data included baseline CT scans acquired between August 2002 and April 2004 from 1737 deceased subjects and 5740 surviving controls taken from the National Lung Screening Trial. Emphysema scores were computed in the original scans (origES) and after applying resampling, normalization and bullae analysis (normES). We compared the prognostic value of normES versus origES for lung cancer and all-cause mortality by computing the area under the receiver operator characteristic curve (AUC) and the net reclassification improvement (NRI) for follow-up times of 1-7 years. normES was a better predictor of mortality than origES. The 95% confidence intervals for the differences in AUC values indicated a significant difference for all-cause mortality for 2 through 6 years of follow-up, and for lung cancer mortality for 1 through 7 years of follow-up. 95% confidence intervals in NRI values showed a statistically significant improvement in classification for all-cause mortality for 2 through 7 years of follow-up, and for lung cancer mortality for 3 through 7 years of follow-up. Contrary to conventional emphysema score, our normalized emphysema score is a good predictor of all-cause and lung cancer mortality in settings where multiple CT scanners and protocols are used.
A method for automatic segmentation of pulmonary lobes from computed tomography (CT) scans is presented that is robust against incomplete fissures. The method is based on a multiatlas approach in ...which existing lobar segmentations are deformed to test scans in which the fissures, the lungs, and the bronchial tree have been automatically segmented. The key element of our method is a cost function that exploits information from fissures, lung borders, and bronchial tree in an effective way, such that less reliable information (lungs, airways) is only used when the most reliable information (fissures) is missing. To cope with the anatomical variation in lobe shape, an atlas selection mechanism is introduced. The method is evaluated on two test sets of 120 scans in total. The results show that the lobe segmentation closely follows the fissures when they are present. In a simulated experiment in which parts of complete fissures are removed, the robustness of the method against different levels of incomplete fissures is shown. When the fissures are incomplete, an observer study shows agreement of the automatically determined lobe borders with a radiologist for 81% of the lobe borders on average.
We aimed to evaluate the effects of four-dimensional noise reduction filtering using a similarity algorithm (4D-SF) on the image quality and hemodynamic parameter of dynamic myocardial computed ...tomography perfusion (CTP). Sixty-eight patients who underwent dynamic myocardial CTP for the assessment of coronary artery disease were enrolled. Dynamic CTP was performed using a 320-row CT with low tube voltage scan (80 kVp). Two different datasets of dynamic CTP were reconstructed using iterative reconstruction (IR) alone and a combination of IR and 4D-SF. Qualitative (5-grade scale) and quantitative image quality scores were assessed, and the CT-derived myocardial blood flow (CT-MBF) was quantified. These results were compared between the two different CTP images. The qualitative image quality in CTP images reconstructed with IR and 4D-SF was significantly higher than that with IR alone (noise score: 4.7 vs. 3.4,
p
< 0.05). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in CTP images reconstructed with IR and 4D-SF were significantly higher than those with IR alone (SNR: 20.6 vs. 9.7; CNR: 7.9 vs. 3.9, respectively;
p
< 0.05). There was no significant difference in mean CT-MBF between the two sets of CTP images (3.01 vs. 3.03 mL/g/min,
p
= 0.1081). 4D-SF showed incremental value in improving image quality in combination with IR without altering CT-MBF quantification in dynamic myocardial CTP imaging with a low tube potential.
In coronavirus disease 2019 (COVID-19), endothelial cells play a central role and an inadequate response is associated with vascular complications. PET imaging with gallium-68 labelled RGD-peptide (
...Ga-RGD) targets α
β
integrin expression which allows quantification of endothelial activation. In this single-center, prospective observational study, we included ten hospitalized patients with COVID-19 between October 2020 and January 2021. Patients underwent
Ga-RGD PET/CT followed by iodine mapping of lung parenchyma. CT-based segmentation of lung parenchyma, carotid arteries and myocardium was used to quantify tracer uptake by calculating standardized uptake values (SUV). Five non-COVID-19 patients were used as reference. The study population was 68.5 (IQR 52.0-74.5) years old, with median oxygen need of 3 l/min (IQR 0.9-4.0).
Ga-RGD uptake quantified as SUV ± SD was increased in lungs (0.99 ± 0.32 vs. 0.45 ± 0.18, p < 0.01) and myocardium (3.44 ± 1.59 vs. 0.65 ± 0.22, p < 0.01) of COVID-19 patients compared to reference but not in the carotid arteries. Iodine maps showed local variations in parenchymal perfusion but no correlation with SUV. In conclusion, using
Ga-RGD PET/CT in COVID-19 patients admitted with respiratory symptoms, we demonstrated increased endothelial activation in the lung parenchyma and myocardium. Our findings indicate the involvement of increased and localized endothelial cell activation in the cardiopulmonary system in COVID-19 patients.Trail registration: NCT04596943.
To suggest a simple and robust technique used to reconstruct high-quality computed tomographic (CT) angiographic images from CT perfusion data and to compare it with currently used CT angiography ...techniques.
Institutional review board approval was waived for this retrospective study, which included 25 consecutive patients who had had a stroke. Temporal maximum intensity projection (tMIP) CT angiographic images were created by using prior temporal filtering as a timing-insensitive technique to produce CT angiographic images from CT perfusion data. The temporal filter strength was optimized to gain maximal contrast-to-noise ratios (CNRs) in the circle of Willis. The resulting timing-invariant (TI) CT angiography was compared with standard helical CT angiography, the arterial phase of dynamic CT angiography, and nonfiltered tMIP CT angiography. Vascular contrast, image noise, and CNR were measured. Four experienced observers scored all images for vascular noise, vascular contour, detail of small and medium arteries, venous superimposition, and overall image quality in a blinded side-by-side comparison. Measurements were compared with a paired t test; P ≤ .05 indicated a significant difference.
On average, optimized temporal filtering in TI CT angiography increased CNR by 18% and decreased image noise by 18% at the expense of a decrease in vascular contrast of 3% when compared with nonfiltered tMIP CT angiography. CNR, image noise, vascular noise, vascular contour, detail visibility of small and medium arteries, and overall image quality of TI CT angiograms were superior to those of standard CT angiography, tMIP CT angiography, and the arterial phase of dynamic CT angiography at a vascular contrast that was similar to that of standard CT angiography. Venous superimposition was similar for all techniques. Image quality of the arterial phase of dynamic CT angiography was rated inferior to that of standard CT angiography.
TI CT angiographic images constructed by using temporally filtered tMIP CT angiographic data have excellent image quality that is superior to that achieved with currently used techniques, but they suffer from modest venous superimposition.
With more than 900,000 confirmed cases worldwide and nearly 50,000 deaths during the first 3 months of 2020, the coronavirus disease 2019 (COVID-19) pandemic has emerged as an unprecedented health ...care crisis. The spread of COVID-19 has been heterogeneous, resulting in some regions having sporadic transmission and relatively few hospitalized patients with COVID-19 and others having community transmission that has led to overwhelming numbers of severe cases. For these regions, health care delivery has been disrupted and compromised by critical resource constraints in diagnostic testing, hospital beds, ventilators, and health care workers who have fallen ill to the virus exacerbated by shortages of personal protective equipment. Although mild cases mimic common upper respiratory viral infections, respiratory dysfunction becomes the principal source of morbidity and mortality as the disease advances. Thoracic imaging with chest radiography and CT are key tools for pulmonary disease diagnosis and management, but their role in the management of COVID-19 has not been considered within the multivariable context of the severity of respiratory disease, pretest probability, risk factors for disease progression, and critical resource constraints. To address this deficit, a multidisciplinary panel comprised principally of radiologists and pulmonologists from 10 countries with experience managing patients with COVID-19 across a spectrum of health care environments evaluated the utility of imaging within three scenarios representing varying risk factors, community conditions, and resource constraints. Fourteen key questions, corresponding to 11 decision points within the three scenarios and three additional clinical situations, were rated by the panel based on the anticipated value of the information that thoracic imaging would be expected to provide. The results were aggregated, resulting in five main and three additional recommendations intended to guide medical practitioners in the use of chest radiography and CT in the management of COVID-19.
The purpose of this case–cohort study was to investigate whether the frequency and computed tomography (CT) features of pulmonary nodules posed a risk for the future development of lung cancer (LC) ...at a different location. Patients scanned between 2004 and 2012 at two Dutch academic hospitals were cross-linked with the Dutch Cancer Registry. All patients who were diagnosed with LC by 2014 and a random selection of LC-free patients were considered. LC patients who were determined to be LC-free at the time of the scan and all LC-free patients with an adequate scan were included. The nodule count and types (solid, part-solid, ground-glass, and perifissural) were recorded per scan. Age, sex, and other CT measures were included to control for confounding factors. The cohort included 163 LC patients and 1178 LC-free patients. Cox regression revealed that the number of ground-glass nodules and part-solid nodules present were positively correlated to future LC risk. The area under the receiver operating curve of parsimonious models with and without nodule type information were 0.827 and 0.802, respectively. The presence of subsolid nodules in a clinical setting may be a risk factor for future LC development in another pulmonary location in a dose-dependent manner. Replication of the results in screening cohorts is required for maximum utility of these findings.
Multidetector-row computed tomography (MDCT), a recent breakthrough in computed tomography (CT) technology, is increasingly available in veterinary practice. The main advantage of MDCT over previous ...CT generations is the ability to acquire thin-section data from a scan volume within a short scan time. The relationship between speed and section thickness has been doubling roughly every 2
year in the past decade, resulting in markedly increased speed of scanning and superb image quality. Datasets obtained from MDCT scanners can be displayed as volume using computer workstations. Given the shorter scanning time and the higher image quality, there is vast potential for new applications of MDCT in small animal imaging. This article provides an overview of the technical basis of MDCT and discusses the current applications of its use in small animals, namely angiographic studies, abdominal, thoracic, and whole-body applications, and in vivo anatomy studies.
The upper respiratory tract (URT) is the entry site for severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2), from where it further disseminates. Early and effective adaptive immune responses ...are crucial to restrict viral replication and limit symptom development and transmission. Current vaccines increasingly incorporate strategies to boost mucosal immunity in the respiratory tract. Positron emission tomography (PET) is a non-invasive technology that measures cellular responses at a whole-body level. In this case series, we explored the feasibility of 89 ZrZr-crefmirlimab berdoxam PET to assess CD8+ T-cell localization during active COVID-19. Our results suggest that CD8+ T-cell distributions assessed by PET imaging reflect their differentiation and functional state in blood. Therefore, PET imaging may represent a novel tool to visualize and quantify cellular immune responses during infections at a whole-body level.