The objective of this study was to evaluate the elimination kinetics of hemostasis-related biomarkers including the prothrombin activation fragment F1+2, thrombin-antithrombin complex (TAT), ...plasmin-α2-antiplasmin complex (PAP), and D-dimer in humans. Autologous serum was used as a biomarker source and infused into 15 healthy volunteers. Serum was prepared from whole blood in the presence of recombinant tissue-type plasminogen activator (final concentration 20 μg/mL) to induce plasmin generation required for PAP and D-dimer formation. Serum transfusions (50 mL/30 min) were well tolerated by all subjects. Endogenous thrombin formation was not induced by serum infusions as measured using a highly sensitive oligonucleotide-based enzyme capture assay. Median peak levels (x-fold increase over baseline) of F1+2, TAT, PAP, and D-dimer of 3.7 nmol/L (28.9), 393 ng/mL (189.6), 3,829 ng/mL (7.0), and 13.4 mg/L (34.2) were achieved at the end of serum infusions. During a 48 h lasting follow-up period all biomarkers showed elimination kinetics of a two-compartment model. Median (interquartile range) terminal half-lives were 1.9 (1.3-3.6) h for F1+2, 0.7 (0.7-2.6) h for TAT, and 10.8 (8.8-11.4) h for PAP. With 15.8 (13.1-23.1) h the D-dimer half-life was about twice as long as previously estimated from radiolabeling studies in animals and small numbers of human subjects. The serum approach presented here allows label-free and simultaneous analysis of the elimination kinetics of various hemostasis-related biomarkers. Based on these data changes in biomarker levels could more precisely used to estimate the activity level of the hemostatic system.
Axial flow pumps are standard treatment in cases of cardiogenic shock and high-risk interventions in cardiology and cardiac surgery, although the optimal anticoagulation strategy remains unclear. We ...evaluated whether laboratory findings could predict bleeding complications and acquired von Willebrand syndrome (avWS) among patients who were treated using axial flow pumps. We retrospectively evaluated 60 consecutive patients who received Impella devices (Impella RP: n = 20, Impella CP/5.0: n = 40; Abiomed Inc., Danvers, USA) between January 2019 and December 2020. Thirty-two patients (53.3%) experienced major or fatal bleeding complications (Bleeding Academic Research Consortium score of > 3) despite intravenous heparin being used to maintain normal activated partial thromboplastin times (40-50 s). Extensive testing was performed for 28 patients with bleeding complications (87.5%). Relative to patients with left ventricular support, patients with right ventricular support were less likely to develop avWS (87.5% vs. 58.8%, p = 0.035). Bleeding was significantly associated with avWS (odds ratio OR: 20.8, 95% confidence interval CI: 3.3-128.5; p = 0.001) and treatment duration (OR: 1.3, 95% CI 1.09-1.55; p = 0.003). Patients with avWS had longer Impella treatment than patients without avWS (2 days 1-4.7 days vs. 7.3 days 3.2-13.0 days). Bleeding complications during Impella support were associated with avWS in our cohort, while aPTT monitoring was not sufficient to prevent bleeding complications. A more targeted anticoagulation monitoring might be needed for patients who receive Impella devices.
Activated protein C (APC) is a serine protease with anticoagulant and cytoprotective activities which make it an attractive target for diagnostic and therapeutic applications. In this work, we ...present one-step activation of APC from a commercial source of protein C (PC, Ceprotin) followed by rapid and efficient purification using an APC-specific aptamer, HS02-52G, loaded on MyOne superparamagnetic beads. Due to the Ca
-dependent binding of APC to HS02-52G, an efficient capturing of APC was applied in the presence of Ca
ions, while a gentle release of captured APC was achieved in the elution buffer containing low EDTA concentration (5 mM). The captured and eluted APC showed more than 95% purity according to SDS-PAGE gel analysis and an enzyme-linked fluorescent assay (VIDAS Protein C). The purification yield of 45% was calculated when 4.2 µg APC was used, however this yield reduced to 21% if the starting amount of APC increased to 28.5 µg. Altogether, this method is recommended for rapid and efficient PC activation and APC purification. The purified APC can be used directly for downstream processes where high concentration of pure and active APC is needed.
Abstract
Functional tests for lupus anticoagulants (LA) as part of a thrombophilia workup are commonly performed in patients under anticoagulant therapy that may interfere with assay results. There ...is no consensus on how these tests should be assessed in patients on direct oral anticoagulants (DOACs). In this retrospective cohort study, we analysed data from patients with a history of thrombosis in whom dilute Russell viper venom time (dRVVT), LA-sensitive aPTT, and solid phase assays for antiphospholipid antibodies (aPL) were performed (n = 3,147, thereof 588 on rivaroxaban, 144 on apixaban, 1,179 on other anticoagulant drugs). The dRVVT ratio was correlated with rivaroxaban (r = 0.30,
P
< 10
–4
) but not with apixaban plasma levels. The LA-sensitive aPTT/aPTT ratio showed no correlation with DOAC levels. Correspondingly, the rate of patients with abnormal dRVVT test was significantly higher (
P
< 10
–4
) under rivaroxaban (88%) than in thrombosis patients without anticoagulant medication (6%), independent from their aPL plasma levels. No isolated positive results of functional LA testing in patients on anticoagulants could be confirmed in repeated testing after discontinuation of the medication (n = 40). These data indicate that rivaroxaban should be discontinued before functional LA testing is performed. However, viable interpretation of these tests appears to be less affected in patients on apixaban.
Inactivation of thrombin by the endogenous inhibitor antithrombin (AT) is a central mechanism in the regulation of hemostasis. This makes hereditary AT deficiency, which is caused by SERPINC1 gene ...mutations, a major thrombophilic risk factor. Aim of this study was to assess to what extent AT mutations impair thrombin inhibition kinetics. The study population included 36 thrombophilic patients with 19 different mutations and mean AT levels of 65% in a thrombin-based functional assay, and 26 healthy controls. To assess thrombin inhibition kinetics, thrombin (3.94 mU/mL final concentration) was added to citrated plasma. Subsequently, endogenous thrombin inhibition was stopped by addition of the reversible thrombin inhibitor argatroban and the amount of argatroban-complexed thrombin quantified using an oligonucleotide-based enzyme capture assay. The plasma half-life of human thrombin was significantly longer in patients with AT mutations than in the controls (119.9 versus 55.9 s). Moreover, it was disproportionately prolonged when compared with preparations of wild type AT in plasma, in whom a comparable thrombin half-life of 120.8 s was reached at a distinctly lower AT level of 20%. These findings may help to better understand the increased thrombotic risk of SERPINC1 mutations with near normal AT plasma levels in functional assays.
Congenital factor VII (FVII) deficiency is a rare genetic bleeding disorder characterized by deficient or reduced activity of coagulation FVII. It is caused by genetic variants in the
gene. We aimed ...to evaluate the rate of detection of pathogenic variants in the
gene in a large group of patients with FVII deficiency and investigate the correlations between the
genotype and FVII activity (FVII:C). Moreover, the influence of the common genetic variant rs6046: c.1238G>A; p.(Arg413Gln), designated as the M2 allele, on FVII:C was investigated. Genetic analysis of the
gene was performed on 704 index patients (IPs) using either direct Sanger- or next-generation sequencing. Genetic variants were detected in 390 IPs, yielding a variant detection rate (VDR) of 55%. Notably, the VDR exhibited a linear decline with increasing FVII:C levels. We identified 124 genetic variants, of which 48 were not previously reported. Overall, the frequency of the M2 allele was considerably higher in patients with mild deficiency (FVII:C > 20 IU/dl). Furthermore, IPs lacking an identified pathogenic variant exhibited a significantly higher prevalence of the M2 allele (69%) compared to IPs with a disease-causing variant (47%). These results strongly support the association of the M2 allele with decreased FVII:C levels. This study shows the utility of FVII:C as a predictive marker for identifying pathogenic variants in patients with FVII deficiency. The M2 allele contributes to the reduction of FVII:C levels, particularly in cases of mild deficiency.
Aim: Feedback activation of factor XI (FXI) by thrombin is believed to play a critical role in the amplification phase of thrombin generation and to contribute to thrombosis development and ...hemostasis. However, the activation of FXI by thrombin has been shown in vitro to require a cofactor. In this study, the role of thrombin in activated FXI (FXIa) formation in vivo is investigated. Methods: The study population comprised probands in whom coagulation activation was triggered by low-dose (15 µg/kg) recombinant activated factor VII (rFVIIa, n=89), of whom 34 with (VTE+) and 45 without a history of venous thromboembolism (VTE−), and patients undergoing major orthopedic surgeries (n=45). FXIa was quantified via an enzyme capture assay using a monoclonal FXI-specific antibody. Thrombin formation was monitored using an oligonucleotide-based enzyme capture assay and the thrombin activation markers prothrombin fragment 1+2 (F1+2) and thrombin–antithrombin complex (TAT). Results: In the rFVIIa cohort, FXIa and thrombin remained below their lower limit of quantification of 3.48 and 1.06 pmol/L, respectively. By contrast, during the surgeries, median FXIa levels increased from 3.69 pmol/L pre-operatively to 9.41 pmol/L mid-operatively (P=4·10−4) and remained significantly elevated 24 h thereafter, with 9.38 pmol/L (P=0.001). Peak levels of F1+2 were comparable in the VTE+, VTE−, and surgery cohort (235, 268, and 253 pmol/L), whereas peak TAT levels were higher in the surgery cohort (53.1, 33.9, and 147.6 pmol/L). Conclusions: Under in vivo conditions, the activation of FXI requires specific local features that are present at the wounded site including potential cofactors of thrombin.
A disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13 (ADAMTS-13) is a metalloprotease that regulates the size of circulating von Willebrand factor (vWF) multimers. Severe ...lack of ADAMTS-13 activity <10% of normal (0.1 IU/mL) leads to thrombotic thrombocytopenic purpura (TTP), a specific type of thrombotic microangiopathy (TMA). Timely determination of plasma ADAMTS-13 activity is essential to discriminate TTP from other types of TMA with respect to adequate treatment. Identification of the minimal substrate motif for ADAMTS-13 within the A2 domain of vWF (vWF73) as well as the generation of monoclonal antibodies (mAbs) that specifically recognize the ADAMTS-13 cleavage site enabled the development of a variety of methods for determination of plasma ADAMTS-13 activity. In order to further extend the range of analytical platforms applicable for quantitative determination of plasma ADAMTS-13 activity, a specific, vWF/mAb-based assay with flow cytometric readout was developed and validated. Basic assay characteristics include a total assay time of 80 to 90 min, a near linear dynamic range from 0.005 (lower limit of quantification) to 0.2 IU/mL, and intra- and interassay coefficients of variation below 5 and 30% at input plasma ADAMTS-13 activities of 0.015 and ≤0.050 IU/mL, respectively. When compared to the results obtained with a commercially available quantitative ADAMTS-13 activity ELISA, analysis of 18 plasma samples obtained from patients with suspected TTP revealed full agreement of results with respect to the clinical 0.1 IU/mL TTP threshold. Based on these data, it is assumed that the described assay principle can be successfully transferred to virtually all laboratories that have a flow cytometer available.