(ProQuest: ... denotes formulae and/or non-USASCII text omitted; see image).The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES ...will perform a calorimetric measurement of the energy released in the decay of ...Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted ...Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.
An updated overview of the HOLMES status Borghesi, M.; Alpert, B.; Balata, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/2023, Letnik:
1051
Journal Article
Recenzirano
Odprti dostop
HOLMES is an ERC project started in 2014 that will perform a model independent measurement of the neutrino mass with a sensitivity of the order of 1 eV. In order to reach its goal sensitivity, HOLMES ...will use 1000 low temperature microcalorimeters, each implanted with an activity of 300 Bq of 163Ho, performing thus a calorimetric measurement. This contribution presents the recent results achieved that lay the grounds for the low-activity phase of the HOLMES experiment, that will lead to its first limit on the neutrino mass.
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only ...experimental method which can provide a model-independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope
163
Ho. In a calorimetric measurement, the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. The most suitable detectors for this type of measurement are low-temperature thermal detectors, where all the energy released into an absorber is converted into a temperature increase that can be measured by a sensitive thermometer directly coupled with the absorber. This measurement was originally proposed by De Rujula and Lusignoli (Nucl Phys B 219:277,
1983
.
https://doi.org/10.1016/0550-3213(83)90642-9
), but only in the last decade the technological progress in detectors development has allowed to design a sensitive experiment. HOLMES plans to deploy a large array of low-temperature microcalorimeters with implanted
163
Ho nuclei. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives.
This paper describes the production and chemical separation of the 163Ho isotope that will be used in several nuclear physics experiments aiming at measuring the neutrino mass as well as the neutron ...cross section of the 163Ho isotope. For this purpose, several batches of enriched 162Er have been irradiated at the Institut Laue-Langevin high flux reactor to finally produce 6 mg or 100 MBq of the desired 163Ho isotope. A portion of the Er/Ho mixture is then subjected to a sophisticated chemical separation involving ion exchange chromatography to isolate the Ho product from the Er target material. Before irradiation, a thorough analysis of the impurity content was performed and its implication on the produced nuclide inventory will be discussed.
The HOLMES experiment aims to directly measure the
ν
mass studying the
163
Ho electron capture decay spectrum developing arrays of TES-based microcalorimeters implanted with O(300 Bq/detector) Ho ...atoms. The embedding of the source inside detectors is a crucial step of the experiment. Because the
163
Ho production process (neutron irradiation of a
162
Er sample) is not perfectly free from impurities, Ho source must be separated from a lot of contaminants. A chemical processing removes every species other than Ho, but it is not sufficient to remove all isotope-related background sources: Indeed,
166
m
Ho beta decay can produce fake signal in the region of interest. For this reason, a dedicated implantation system was set up. It is designed to achieve the separation power better than 5
σ
at 163/166 a.m.u. allowing an efficient Ho ions implantation inside microcalorimeter absorbers. Its main components are a 50 kV sputter-based ion source, a magnetic dipole and a target chamber. A specially designed co-evaporation system was designed to “grow” the gold microcalorimeter absorber during the implantation process, increasing the maximum achievable activity which can be implanted. The machine performances were evaluated by means of calibration runs using
63
Cu/
65
Cu and Mo beams. A special care was given to the study of the more effective way to populate source plasma with Ho ions obtained from different Ho compounds by sputtering process. In this work, the machine development and commissioning are described.
One of the major challenges in nowadays particle physics and astrophysics is the determination of the absolute neutrino mass scale. A powerful tool to evaluate the effective neutrino mass is the ...calorimetric measurement of the energy released in a nuclear decay involving neutrino. In order to reach a sensitivity on the neutrino mass of the order of 1 eV, not only detectors characterized by high performances (i.e. energy and time resolution of <inline-formula><tex-math notation="LaTeX">\sim</tex-math></inline-formula> eV at keV and <inline-formula><tex-math notation="LaTeX">\sim</tex-math></inline-formula>1 <inline-formula><tex-math notation="LaTeX">\mu</tex-math></inline-formula>s, respectively) are needed but also many detectors working in parallel are required. Microwave frequency readout provides an effective technique to read out large arrays of low temperature detectors allowing to reach a multiplex factor of the order of thousands. This technique is the one used to read out the 1000 Transition Edge Sensors of HOLMES, an experiment that aims at measuring the electron neutrino mass by means of the electron capture (EC) decay of <inline-formula><tex-math notation="LaTeX">^{163}</tex-math></inline-formula>Ho with an expected sensitivity of the order of 1 eV. In this contribution we present the characterization of the microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES.
Status of the HOLMES Experiment Faverzani, M.; Alpert, B.; Balata, M. ...
Journal of low temperature physics,
05/2020, Letnik:
199, Številka:
3-4
Journal Article
Recenzirano
Odprti dostop
The absolute neutrino mass is still an unknown parameter in the modern landscape of particle physics. The HOLMES experiment aims at exploiting the calorimetric approach to directly measure the ...neutrino mass through the kinematic measurement of the decay products of the weak process decay of
163
Ho. This low energy decaying isotope, in fact, undergoes electron capture emitting a neutrino and leaving the daughter atom,
163
Dy
∗
, in an atomic excited state. This, in turn, relaxes by emitting electrons and, to a considerably lesser extent, photons. The high-energy portion of the calorimetric spectrum of this decay is affected by the non-vanishing neutrino mass value. Given the small fraction of events falling within the region of interest, to achieve a high experimental sensitivity on the neutrino mass, it is important to have a high activity combined with a very small undetected pileup contribution. To achieve these targets, the final configuration of HOLMES foresees the deployment of a large number of
163
Ho ion-implanted TESs characterized by an ambitiously high activity of 300 Hz each. In this paper, we outline the status of the major tasks that will bring HOLMES to achieve a statistical sensitivity on the neutrino mass as low as 2 eV/c
2
.
The assessment of the neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only ...experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment to directly measure the neutrino mass by performing a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope 163Ho. In a calorimetric measurement the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. HOLMES will deploy a large array of low temperature microcalorimeters implanted with 163Ho nuclei. The achievable neutrino mass statistical sensitivity is expected in the eV range, thereby making HOLMES an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. HOLMES will also establish the potential of this approach to achieve a sub-eV sensitivity. HOLMES is designed to collect about 3 × 1013 decays with an instrumental energy resolution around 1 eV FWHM and a time resolution around 1 µs. To achieve this in three years of measuring time, HOLMES is going to deploy 16 sub-arrays of TES microcalorimeters. Each sub-array has 64 pixels ion implanted with 163Ho nuclei to give a pixel activity of 300 Bq per pixel. The TES arrays are read out using microwave multiplexed rf-SQUIDs in combination with a Software Designed Radio data acquisition system. The commissioning of the first implanted sub-array is scheduled for 2018 and it will provide first high statistics data about the EC decay of 163Ho together with a preliminary limit on the neutrino mass. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives. In particular we will present the status of the HOLMES activities concerning the 163Ho isotope production by neutron irradiation and purification, the TES pixel design and optimization, the multiplexed array read-out characterization, the cryogenic set-up installation, and the setting up of the mass separation and ion implantation system for the isotope embedding in the TES absorbers.
The main goal in the HOLMES experiment is the neutrino mass measurement using an array of 1000micro-calorimeters with standard metallic absorber. A good isotope for such measurement is the 163Ho, ...those isotopes embedded in the metallic absorber will be 1011–1013. Since 163Ho is not available in nature, a dedicated process must be set up to produce the amount needed for this neutrino mass experiment. The process with the highest born-up cross-section is the neutron irradiation of Er2O3 enriched in 162Er: 162Er(n,γ)163Er →163Ho+νe, where the decay is an EC with half-life of about 75min and the (n,γ) is about 20barns for thermal neutron. After the neutron irradiation in the oxide powder there are several radioactive isotopes which are potentially disturbing because of the background that they cause below 5keV. The chemical separation of holmium from the irradiation enriched Er2O3 powder is therefore mandatory and will be performed by means of ion exchange chromatography. On the end of those processes the oxide powder enriched in 162Er will have the 163Ho isotope number required. The holmium chemical state influences the end point of the EC spectrum, in order to avoid such effect it is necessary to embed in the absorber only the metallic isotope. Reduction and distillation technique allowed us to obtain a pure metallic holmium, starting from natural oxide holmium. This technique will be applied on the irradiated oxide powder to obtain the metallic 163Ho, ready to be embedded in the micro-calorimeter absorber.
Status of the HOLMES detector development Nucciotti, A.; Alpert, B.; Becker, D. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
07/2016, Letnik:
824
Journal Article
Recenzirano
Odprti dostop
HOLMES is a new experiment to directly measure the neutrino mass with a sensitivity as low as 0.4eV. HOLMES will perform a calorimetric measurement of the energy released in the electron capture ...decay of 163Ho. HOLMES will deploy a large array of low temperature microcalorimeters with implanted 163Ho nuclei. HOLMES baseline detector is an array of 1000 microcalorimeters each with an implanted 163Ho activity of about 300 Bq, an energy resolution FWHM of about 1eV at the spectrum end-point (Q≈2.5 keV), and a time resolution of about 1μs. Matching these performances requires a careful optimization of all components, from the microcalorimeters to the signal processing algorithms. We outline here the project technical challenges and the present status of the development.