Abstract
Objectives
To assess the effect of rituximab (RTX) on the lung function parameters in SSc interstitial lung disease (SSc-ILD) patients.
Methods
PubMed and Embase were searched to identify ...studies on SSc-ILD treated with RTX, confined to a predefined inclusion and exclusion criteria. A systematic review and meta-analysis were performed on the included studies on changes in forced vital capacity (FVC) and diffusion capacity of carbon monoxide (DLCO) from baseline to 6 and 12 months of follow-up.
Results
A total of 20 studies (2 randomized controlled trials, 6 prospective studies, 5 retrospective studies and 7 conference abstracts) were included (n = 575). RTX improved FVC from baseline by 4.49% (95% CI 0.25, 8.73) at 6 months and by 7.03% (95% CI 4.37, 9.7) at 12 months. Similarly, RTX improved DLCO by 3.47% (95% CI 0.99, 5.96) at 6 months and 4.08% (95% CI 1.51, 6.65) at 12 months. In the two studies comparing RTX with other immunosuppressants, improvement of FVC by 6 months in the RTX group was 1.03% (95% CI 0.11, 1.94) greater than controls. At the 12 month follow-up, RTX treatment was similar to controls in terms of both FVC and DLCO. Patients treated with RTX had a lower chance of developing infections compared with controls odds ratio 0.256 (95% CI 0.104, 0.626), I2 = 0%, P = 0.47).
Conclusions
Treatment with RTX in SSc-ILD was associated with a significant improvement of both FVC and DLCO during the first year of treatment. RTX use was associated with lower infectious adverse events.
If there is a pleuropulmonary fistula with the opening of fistula below the fluid level in the pleural sac then with every inspiration there may be a whistling sound produced which is called the ...water whistle sign. Amphoric vocal resonance refers to the echoing voice sounds heard typically over cavities or open pneumothorax.Artificial vocal resonance refers to repeated percussion or tapping of the patient's thyroid cartilage in cases of deaf-mutism, aphonia, and coma in order to produce sounds which are auscultated over the chest.
BBV152 is a whole-virion inactivated SARS-CoV-2 vaccine that has been deployed in India. The results of the phase 3 trial have shown clinical efficacy of BBV152. We aimed to evaluate the ...effectiveness of BBV152 against symptomatic RT-PCR-confirmed SARS-CoV-2 infection.
We conducted a test-negative, case-control study among employees of the All India Institute of Medical Sciences (a tertiary care hospital in New Delhi, India), who had symptoms suggestive of COVID-19 and had an RT-PCR test for SARS-CoV-2 during the peak of the second wave of the COVID-19 pandemic in India between April 15 and May 15, 2021. Cases (test-positives) and controls (test-negatives) were matched (1:1) on the basis of age and gender. The odds of vaccination with BBV152 were compared between cases and controls and adjusted for level of occupational exposure (to COVID-19), previous SARS-CoV-2 infection, and calendar time, using conditional logistic regression. The primary outcome was effectiveness of two doses of BBV152 (with the second dose received at least 14 days before testing) in reducing the odds of symptomatic RT-PCR-confirmed SARS-CoV-2 infection, expressed as (1 – odds ratio) × 100%.
Between April 15 and May 15, 2021, 3732 individuals had an RT-PCR test. Of these, 2714 symptomatic employees had data on vaccination status, and 1068 matched case-control pairs were available for analysis. The adjusted effectiveness of BBV152 against symptomatic COVID-19 after two doses administered at least 14 days before testing was 50% (95% CI 33–62; p<0·0001). The adjusted effectiveness of two doses administered at least 28 days before testing was 46% (95% CI 22–62) and administered at least 42 days before testing was 57% (21–76). After excluding participants with previous SARS-CoV-2 infections, the adjusted effectiveness of two doses administered at least 14 days before testing was 47% (95% CI 29–61).
This study shows the effectiveness of two doses of BBV152 against symptomatic COVID-19 in the context of a huge surge in cases, presumably dominated by the potentially immune-evasive delta (B.1.617.2) variant of SARS-CoV-2. Our findings support the ongoing roll-out of this vaccine to help control the spread of SARS-CoV-2, while continuing the emphasis on adherence to non-pharmacological measures.
None.
For the Hindi translation of the abstract see Supplementary Materials section.
Abstract
Infrared thermal screening, via the use of handheld non-contact infrared thermometers (NCITs) and thermal scanners, has been widely implemented all over the world. We performed a systematic ...review and meta-analysis to investigate its diagnostic accuracy for the detection of fever. We searched PubMed, Embase, the Cochrane Library, medRxiv, bioRxiv, ClinicalTrials.gov, COVID-19 Open Research Dataset, COVID-19 research database, Epistemonikos, EPPI-Centre, World Health Organization International Clinical Trials Registry Platform, Scopus and Web of Science databases for studies where a non-contact infrared device was used to detect fever against a reference standard of conventional thermometers. Forest plots and Hierarchical Summary Receiver Operating Characteristics curves were used to describe the pooled summary estimates of sensitivity, specificity and diagnostic odds ratio. From a total of 1063 results, 30 studies were included in the qualitative synthesis, of which 19 were included in the meta-analysis. The pooled sensitivity and specificity were 0.808 (95%CI 0.656–0.903) and 0.920 (95%CI 0.769–0.975), respectively, for the NCITs (using forehead as the site of measurement), and 0.818 (95%CI 0.758–0.866) and 0.923 (95%CI 0.823–0.969), respectively, for thermal scanners. The sensitivity of NCITs increased on use of rectal temperature as the reference. The sensitivity of thermal scanners decreased in a disease outbreak/pandemic setting. Changes approaching statistical significance were also observed on the exclusion of neonates from the analysis. Thermal screening had a low positive predictive value, especially at the initial stage of an outbreak, whereas the negative predictive value (NPV) continued to be high even at later stages. Thermal screening has reasonable diagnostic accuracy in the detection of fever, although it may vary with changes in subject characteristics, setting, index test and the reference standard used. Thermal screening has a good NPV even during a pandemic. The policymakers must take into consideration the factors surrounding the screening strategy while forming ad-hoc guidelines.
Angiotensin-converting enzyme 2 (ACE2) is a key host protein by which severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) enters and multiplies within cells. The level of ACE2 expression in ...the lung is hypothesised to correlate with an increased risk of severe infection and complications in COrona VIrus Disease 2019 (COVID-19). To test this hypothesis, we compared the protein expression status of ACE2 by immunohistochemistry (IHC) in post-mortem lung samples of patients who died of severe COVID-19 and lung samples obtained from non-COVID-19 patients for other indications. IHC for CD61 and CD163 was performed for the assessment of platelet-rich microthrombi and macrophages, respectively. IHC for SARS-CoV-2 viral antigen was also performed. In a total of 55, 44 COVID-19 post-mortem lung samples were tested for ACE2, 36 for CD163, and 26 for CD61, compared to 15 non-covid 19 control lung sections. Quantification of immunostaining, random sampling, and correlation analysis were used to substantiate the morphologic findings. Our results show that ACE2 protein expression was significantly higher in COVID-19 post-mortem lung tissues than in controls, regardless of sample size. Histomorphology in COVID-19 lungs showed diffuse alveolar damage (DAD), acute bronchopneumonia, and acute lung injury with SARS-CoV-2 viral protein detected in a subset of cases. ACE2 expression levels were positively correlated with increased expression levels of CD61 and CD163. In conclusion, our results show significantly higher ACE2 protein expression in severe COVID-19 disease, correlating with increased macrophage infiltration and microthrombi, suggesting a pathobiological role in disease severity.
In spite of the scale-free degree distribution that characterizes most protein interaction networks (PINs), it is common to define an ad hoc degree scale that defines "hub" proteins having special ...topological and functional significance. This raises the concern that some conclusions on the functional significance of proteins based on network properties may not be robust.
In this paper we present three objective methods to define hub proteins in PINs: one is a purely topological method and two others are based on gene expression and function. By applying these methods to four distinct PINs, we examine the extent of agreement among these methods and implications of these results on network construction.
We find that the methods agree well for networks that contain a balance between error-free and unbiased interactions, indicating that the hub concept is meaningful for such networks.