Stroke is a significant complication in patients supported with continuous-flow left ventricular assist devices (CF-LVAD) and hypertension is a significant risk factor for stroke, but the association ...between blood pressure and stroke in LVAD patients is not well characterized.
We identified 275 consecutive patients who survived implant hospitalization between January 2005 and April 2013. Patients were grouped according to systolic blood pressure (SBP) as above a median and below a median of 100 mm Hg by their averaged systolic blood pressure during the 48 hours before discharge from implantation hospitalization. The groups were compared for the primary outcome of time to stroke.
The above-median SBP group had mean SBP of 110 mm Hg and the below-median SBP group had mean SBP of 95 mm Hg. There were no significant between-group differences in body mass index, smoking, vascular disease, hypertension, atrial fibrillation, or prior stroke. During a mean follow-up of 16 months, stroke occurred in 16% of the above-median SBP group vs in 7% of the below-median SBP group (hazard ratio, 2.38; 95% confidence interval, 1.11-5.11), with a similar proportion of hemorrhagic and ischemic strokes in each group. In Cox proportional hazard models adjusting for age, diabetes, or prior stroke, the hazard ratio remained statistically significant. SBP as a continuous variable predictor of stroke had an area under the curve of 0.64 in a receiver operating characteristic curve analysis.
In this large, CF-LVAD cohort, elevated SBP was independently associated with a greater risk of subsequent stroke. These results identify management of hypertension as a potential modifiable risk factor for reducing the incidence of stroke in patients supported by CF-LVAD.
We evaluated thrombotic and bleeding outcomes in patients with continuous-flow left ventricular assist devices (CF-LVADs), stratified by anticoagulation intensity. Previous studies of outpatients ...with CF-LVADs have suggested that target international normalized ratio (INR) values <2.5 (range, 2-3) may be used. However, recent studies reported an increase in pump thrombosis among CF-LVADs, especially within the first 6 months of implant.
We retrospectively reviewed 249 outpatients at our center who received a CF-LVAD between January 2005 and August 2013. Using Poisson models, we analyzed their 10 927 INRs to determine INR-specific rates of thrombotic (ischemic stroke and suspected pump thrombosis) and hemorrhagic (gastrointestinal bleeding and hemorrhagic stroke) events occurring outside of the hospital. In multivariate analyses, we adjusted for age, sex, atrial fibrillation, coronary disease, and LVAD type as time-dependent Cox proportional hazard models. During a mean follow-up of 17.6±13.6 months, thrombotic events occurred in 46 outpatients. The highest event rate (0.40 thrombotic events per patient-year) was in the INR range of <1.5, but INR values of 1.5 to 1.99 also had high rates (0.16 thrombotic events per patient-year). INR was inversely associated with thrombotic events (hazard ratio, 0.40; 95% confidence interval, 0.22-0.72; P=0.002). The optimal INR based on weighted mortality of thrombotic and bleeding events was 2.6.
INR is inversely related to thrombotic events occurring outside of the hospital among patients supported with CF-LVADs. INR values <2.0 increase the rate of thrombotic events occurring outside of the hospital among patients supported with CF-LVADs.
Abstract Objectives This study sought to determine whether severe right ventricular (RV) dysfunction in the pre-operative setting is associated with an increased risk of gastrointestinal bleeding ...(GIB) post-left ventricular assist device (LVAD). Background GIB is a significant complication in patients supported with continuous-flow LVADs. The impact of RV dysfunction on the risk of GIB has not been investigated. Methods We retrospectively identified 212 patients who survived index hospitalization after implantation of HeartMate II (Thoratec Corp., Pleasanton, California) or Heartware HVAD (HeartWare Corp., Framingham, Massachusetts) from June 2009 to April 2013. Patients with severe RV dysfunction on pre-LVAD echocardiogram (n = 37) were compared to patients without severe RV dysfunction (n = 175). The primary outcome was freedom from GIB. Results The majority of patients were male (79%) with a median INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profile of 2 at LVAD implantation. There were no significant differences between cohorts with respect to demographics, comorbidities, device type, international normalization ratio, or aspirin strategy. During follow-up, 81 patients had GIB events: 23 of 37 (62%) in the severe RV dysfunction group versus 58 of 175 (33%) in the control group (p = 0.001). After adjustment for age and ischemic cardiomyopathy, severe RV dysfunction was associated with increased risk of GIB (hazard ratio: 1.799, 95% confidence interval: 1.089 to 2.973, p = 0.022). Conclusions In this single-center sample of patients supported with continuous-flow LVADs, severe RV dysfunction on pre-LVAD echocardiogram was associated with an increased risk of GIB. Further studies are needed to investigate possible mechanisms by which RV dysfunction increases the risk of GIB and to identify patient populations who may benefit from alterations in antithrombotic strategies.
Primary graft dysfunction (PGD) is a potentially devastating complication of heart transplantation. Understanding the risk factors for PGD in the modern era of heart transplantation is of vital ...importance. This study investigated the relationship between post-left ventricular assist device (LVAD) right heart failure (RHF) and transplant outcomes. Patients with durable, continuous-flow LVADs who were transplanted between 2010 and 2016 at Barnes-Jewish Hospital were included in the study. Data collection was performed through retrospective chart review. The primary outcome was the incidence of PGD stratified by pretransplant incidence of RHF while on LVAD support. Among the 141 patients included in the study, 41 developed RHF. In the RHF cohort, 18 patients developed PGD as compared to 14 patients in the group without RHF (44% vs. 14%; p < 0.001). Mortality was significantly higher in the RHF group at 30 days (20% vs. 1%; p < 0.001) and 1 year (22% vs. 6%; p = 0.013). In a multivariable logistic regression model adjusted for confounding variables, RHF was associated with a nearly fourfold increased risk of PGD (odds ratio, 3.91; p = 0.003). The results of this study show that patients supported with LVADs who develop early severe RHF or late RHF are at increased risk of PGD and death following cardiac transplantation.
Orthotopic heart transplant (OHT) recipients are at increased risk for morbidity and mortality after SARS-CoV-2 infection. Although antibody response to COVID-19 vaccination is lower in solid organ ...transplant recipients, there has been no study assessing the safety and effectiveness of COVID-19 vaccination in OHT recipients.
To assess the safety and effectiveness of COVID-19 vaccination and associations with SARS-CoV-2 infection and clinical outcomes in a large population of adult OHT recipients.
This case-control study examined data from a US heart transplant program at a single center for all adult recipients of OHT who were followed up from January 15, 2021, through January 31, 2022.
The primary outcome was number of SARS-CoV-2 infections and related hospitalizations, intensive care unit (ICU) admissions, and deaths between vaccinated vs unvaccinated adult recipients of OHT.
A total of 436 patients who received OHT were included in the study, of which 106 patients were infected with COVID-19. The mean (SD) age was 54 (17) years; 303 (69.5%) were men and 133 (30.5%) were women. There were 366 patients in the vaccinated cohort with 72 COVID-19 infections (19.7%), 15 hospitalizations (4.1%), 4 ICU admissions (1.1%), and 3 deaths (0.8%). There were 70 patients in the unvaccinated cohort with 34 COVID-19 infections (48.6%), 10 hospitalizations (14.3%), 3 ICU admissions (4.3%), and 3 deaths (4.3%). COVID-19 vaccination was associated with a lower risk of COVID-19 infection (risk ratio RR, 0.41; 95% CI, 0.30-0.56), hospitalization (RR, 0.29; 95% CI, 0.14-0.61), and death (RR, 0.19; 95% CI, 0.05-0.82). Among the 366 vaccinated OHT recipients, there was no echocardiographic evidence of graft dysfunction, clinically significant rejection, or allosensitization at 6 months after they received the COVID-19 vaccine.
Patients with OHT who are infected with SARS-CoV-2 are at greater risk of severe infection and death compared with immunocompetent individuals. COVID-19 vaccination was associated with fewer COVID-19 infections, hospitalizations, and deaths, with no heart transplant-specific adverse events. COVID-19 vaccination for all OHT recipients is of paramount importance.
AIM: To assess whether video capsule endoscopy(VCE) affects the outcomes of left ventricular assist devices(LVADs) recipients with gastrointestinal bleeding.METHODS: This is a retrospective study of ...LVAD recipients with obscure gastrointestinal bleeding(OGIB) who underwent VCE at a tertiary medical center between 2005 and 2013. All patients were admitted and monitored with telemetry and all VCE and subsequent endoscopic procedures were performed as inpatients. A VCE study was considered positive only when P2 lesions were found and was regarded as negative if P1 or P0 were identified. All patients were followed until heart transplant, death, or the end of the study.RESULTS: Between 2005 and 2013, 30 patients with LVAD underwent VCE. Completion rate of VCE was 93.3% and there was no capsule retention. No interference of VCE recording or the function of LVAD was found. VCE was positive in 40% of patients(n = 12). The most common finding was active small intestinal bleeding(50%) and small intestinal angiodysplasia(33.3%). There was no difference in the rate of recurrent bleeding between patients with positive and negative VCE study(50.0% vs 55.6%,P = 1.00) during an average of 11.6 ± 9.6 mo follow up. Among patients with positive VCE, the recurrent bleeding rate did not differ whether subsequent endoscopy was performed(50% vs 50%, P = 1.00).CONCLUSION: VCE can be safely performed in LVAD recipients with a diagnostic yield of 40%. VCE does not affect recurrent bleeding in LVAD patients regardless of findings.