3D digital models of the upper limb anatomy represent the starting point for the design process of bespoke devices, such as orthoses and prostheses, which can be modeled on the actual patient's ...anatomy by using CAD (Computer Aided Design) tools. The ongoing research on optical scanning methodologies has allowed the development of technologies that allow the surface reconstruction of the upper limb anatomy through procedures characterized by minimum discomfort for the patient. However, the 3D optical scanning of upper limbs is a complex task that requires solving problematic aspects, such as the difficulty of keeping the hand in a stable position and the presence of artefacts due to involuntary movements. Scientific literature, indeed, investigated different approaches in this regard by either integrating commercial devices, to create customized sensor architectures, or by developing innovative 3D acquisition techniques. The present work is aimed at presenting an overview of the state of the art of optical technologies and sensor architectures for the surface acquisition of upper limb anatomies. The review analyzes the working principles at the basis of existing devices and proposes a categorization of the approaches based on handling, pre/post-processing effort, and potentialities in real-time scanning. An in-depth analysis of strengths and weaknesses of the approaches proposed by the research community is also provided to give valuable support in selecting the most appropriate solution for the specific application to be addressed.
In the shipbuilding industry, the manufacturing of large yacht hulls is a complex process. Metal hulls are traditionally manufactured by welding pre fabricated large steel panels to form the external ...superstructure. A surface finishing process is then carried out in order to obtain a final target surface having a smooth curvature. The methodologies manly rely on manual processes based on the measurement of the as built hull shape through simple testing instrumentation. Well-experienced workers are required, and a great amount of time is usually wasted, thus affecting the overall shipyard competitiveness.
This paper introduces a methodology for automating the measurement process of as built hull yacht shapes. The methodology, which is based on the integration of a robotic system with an optical scanner, provides accurate non contact 3D full field measurements of the hull surface. The placement of the robotic system around the hull shape is determined by a laser total station thus allowing the automatic multi view data registration into a common reference frame. The proposed approach represents the basis for the automation of the whole surface finishing process of large yacht hulls. In this paper, the methodology has been tested by measuring a large broadside area of a 59m hull assembled within a shipyard.
► We present a method for the automation of the measurement process of large yacht hulls. ► Structured light scanning is used to provide non-contact 3D full-field surface data. ► A robotic system, tracked by a laser station, has been assembled to handle the scanner. ► Multi-view data are aligned on the basis of photogrammetric calibration procedures. ► Results attest the feasibility of the approach for a surface finishing automation.
This study presents an alternative process for designing and manufacturing customized trays for dental-whitening treatments. The process is based on a digitized approach consisting of three main ...stages: design of a reference model, its manufacturing by AM, and thermoforming of the tray. The aim of the study was to develop a high-performance tray, able to guarantee comfort, safety, and efficacy for whitening treatments. To evaluate the patient’s experience, some tests under real operating conditions were performed. Twenty people carried out a nighttime treatment of 14 days. Each patient was asked to assess the overall level of satisfaction and the comfort of the tray and its ability to retain the gel. Tooth whitening was also determined according to the VITAPAN scale. All patients involved in the study were satisfied and provided positive feedback about comfort and tightness of the tray. At the end of the treatment, 15 out of 20 patients achieved shade A1 on the VITAPAN scale. The mean improvement in color shades was about 7. These results confirmed the great potential of the proposed dental tray. Its use was proven to guarantee a high level of quality, flexibility, and customization of dental-whitening treatments, improving comfort, safety, and efficacy.
Primary dentition is crucial in influencing the emergence of permanent teeth. Premature primary tooth loss can result in undesired tooth motions and space loss in the permanent dentition. Typically, ...fixed or removable dental appliances are adopted to maintain edentulous space until the eruption of permanent teeth. However, traditional space maintainers have limitations in terms of variability in tooth anatomy, potential allergic reactions in some individuals (i.e., nickel sensitivity), difficulties in maintaining oral hygiene, and patient acceptance. The present study introduces a fully digital framework for the design and manufacturing of customized pediatric unilateral space maintainers using generative algorithms. The proposed approach overcomes the current challenges by using a biocompatible resin material and optimizing the device’s size, design, and color. The methodology involves intraoral scanning, surface selection, and trim, generative 3D modeling, finite element analysis (FEA), and additive manufacturing (AM) through vat photopolymerization. FEA results demonstrate the device’s mechanical performance and reliability, while additive manufacturing ensures design freedom, high resolution, surface finishing, dimensional accuracy, and proper fit. The mechanical interlocking system facilitates easy and effective positioning of the device. This digital approach offers the potential for wider usage of space maintainers and can be further validated through experimental assessments and clinical studies.
Recent developments in digital imaging techniques have allowed a wide spread of three-dimensional methodologies based on capturing anatomical tissues by different approaches, such as cone-beam ...computed tomography, three-dimensional photography and surface scanning. In oral rehabilitation, an objective method to predict surgical and orthodontic outcomes should be based on anatomical data belonging to soft facial tissue, facial skeleton and dentition (maxillofacial triad). However, none of the available imaging techniques can accurately capture the complete triad. This article presents a multi-modal framework, which allows image fusion of different digital techniques to create a three-dimensional virtual maxillofacial model, which integrates photorealistic face, facial skeleton and dentition. The methodology is based on combining structured light surface scanning and cone-beam computed tomography data processing. The fusion procedure provides multi-modal representations by aligning different tissues on the basis of common anatomical constraints.
A fundamental pre-requisite for the clinical success in dental implant surgery is the fast and stable implant osseointegration. The press-fit phenomenon occurring at implant insertion induces ...biomechanical effects in the bone tissues, which ensure implant primary stability. In the field of dental surgery, the understanding of the key factors governing the osseointegration process still remains of utmost importance. A thorough analysis of the biomechanics of dental implantology requires a detailed knowledge of bone mechanical properties as well as an accurate definition of the jaw bone geometry.
In this work, a CT image-based approach, combined with the Finite Element Method (FEM), has been used to investigate the effect of the drill size on the biomechanics of the dental implant technique. A very accurate model of the human mandible bone segment has been created by processing high resolution micro-CT image data. The press-fit phenomenon has been simulated by FE analyses for different common drill diameters (DA=2.8 mm, DB=3.3 mm, and DC=3.8 mm) with depth L=12 mm. A virtual implant model has been assumed with a cylindrical geometry having height L=11 mm and diameter D=4 mm.
The maximum stresses calculated for drill diameters DA, DB and DC have been 12.31 GPa, 7.74 GPa and 4.52 GPa, respectively. High strain values have been measured in the cortical area for the models of diameters DA and DB, while a uniform distribution has been observed for the model of diameter DC . The maximum logarithmic strains, calculated in nonlinear analyses, have been ϵ=2.46, 0.51 and 0.49 for the three models, respectively.
This study introduces a very powerful, accurate and non-destructive methodology for investigating the effect of the drill size on the biomechanics of the dental implant technique.Further studies could aim at understanding how different drill shapes can determine the optimal press-fit condition with an equally distributed preload on both the cortical and trabecular structure around the implant.
Abstract
The 3D reconstruction of upper limb anatomy plays a significant role in many biomedical fields such as ergonomics, motion rehabilitation, and prosthesis design. In the last few years, the ...technical advancement of consumer-grade depth cameras has supported the development of portable and low-cost optical 3D body scanners for healthcare applications. The real-time scanning of human body parts, however, still represents a complex task due to the non-stationary nature of the scanning target. This issue imposes that the scanning time must be reduced as much as possible to minimize scanning artifacts. In this regard, depth cameras can capture geometrical information at video frame rates, thus guaranteeing fast acquisition times. Furthermore, the simultaneous use of multiple sensors would minimize undercut geometries, which impair the 3D reconstruction’s completeness. In this work, a portable 3D optical scanner has been developed by rigidly assembling three Intel® RealSense™ D415 depth cameras on a lightweight circular frame. The three sensors are mutually calibrated, by using a 3D printed calibration specimen, to simultaneously align acquisitions from the three different camera viewpoints for each scanner pose. The system’s effectiveness has been assessed by acquiring the geometry of both a plaster hand and a human hand and comparing the results with those obtained by a high-end stationary structured light scanner. The developed system represents a low-cost handheld alternative to existing body scanners for collecting and storing 3D anatomical data, which can be used in the design process of bespoke medical devices.
Recent advances in Additive Manufacturing (AM) technologies have allowed a widespread diffusion of their use in different fields. 3D printing is becoming commonplace for biomedical applications ...requiring the custom fabrication of prostheses and appliances fitting patient-specific anatomies. In this work, the feasibility of a vat photopolymerization technology, based on Digital Light Processing (DLP), has been investigated for the manufacturing of polymeric orthodontic appliances. A custom DLP 3D printer has been developed by exploiting an off-the-shelf digital projector, with the aim at studying the influence of printing parameters on the surface roughness. The feasibility of using Dental LT Clear resin, a biocompatible photopolymer specifically designed for SLA technology, has been finally verified.