The paper presents an illustration and empirical study of releasing multiply imputed, fully synthetic public use microdata. Simulations based on data from the US Current Population Survey are used to ...evaluate the potential validity of inferences based on fully synthetic data for a variety of descriptive and analytic estimands, to assess the degree of protection of confidentiality that is afforded by fully synthetic data and to illustrate the specification of synthetic data imputation models. Benefits and limitations of releasing fully synthetic data sets are discussed.
The standardised freight container was one of the most important innovations of the 20th Century. Containerised cargoes travel from their point of origin to their destination by ship, road and rail ...as part of a single journey, without unpacking. This simple concept is the key element in cheap, rapid transport by land and sea, and has led to a phenomenal growth in global trade. Likewise, containerised air cargo has led to a remarkable increase in the inter-continental transportation of goods, particularly perishable items such as flowers, fresh vegetables and live animals. In both cases, containerisation offers great advantages in speed and security, but reduces the opportunity to inspect cargoes in transit. An inevitable consequence is the globalisation of undesirable species of animals, plants and pathogens. Moreover, cheap passenger flights offer worldwide travel for viral and parasitic pathogens in infected humans. The continued emergence of exotic pests, vectors and pathogens throughout the world is an unavoidable consequence of these advances in transportation technology.
To focus on the relationship between pregnancy-related anxiety and spontaneous preterm birth. Psychosocial factors have been the subject of inquiries about the etiology of preterm birth; a factor of ...recent interest is maternal prenatal pregnancy-related anxiety (worries and concerns related to the pregnancy).
From 1991 to 1993, a total of 1820 women completed the study questionnaire during their first prenatal visit to clinics in Baltimore, Maryland. Pregnancy-related anxiety was assessed using six questions from the Prenatal Social Environment Inventory; scores ranged from 0 to 6. Data on pregnancy outcome and clinical and behavioral covariates were obtained from the women's clinical records.
After adjustment for covariates (first or second trimester bleeding, drug use, employment, prior poor pregnancy outcome, smoking, low body mass index, maternal education, age, and race), women with higher levels of pregnancy-related anxiety (scores of 5 or 6) had a significantly increased risk of spontaneous preterm birth compared with those with scores of < or =3.
If additional research confirms these results, then this finding may suggest the possibility of intervention to reduce maternal prenatal pregnancy-related worries and concerns, thereby reducing the risk of spontaneous preterm birth.
Aims
To confirm, in a 26‐week extension study, the sustained efficacy and safety of a fixed combination of insulin degludec and liraglutide (IDegLira) compared with either insulin degludec or ...liraglutide alone, in patients with type 2 diabetes.
Methods
Insulin‐naïve adults with type 2 diabetes randomized to once‐daily IDegLira, insulin degludec or liraglutide, in addition to metformin ± pioglitazone, continued their allocated treatment in this preplanned 26‐week extension of the DUAL I trial.
Results
A total of 78.8% of patients (1311/1663) continued into the extension phase. The mean glycated haemoglobin (HbA1c) concentration at 52 weeks was reduced from baseline by 1.84% (20.2 mmol/mol) for the IDegLira group, 1.40% (15.3 mmol/mol) for the insulin degludec group and 1.21% (13.2 mmol/mol) for the liraglutide group. Of the patients on IDegLira, 78% achieved an HbA1c of <7% (53 mmol/mol) versus 63% of the patients on insulin degludec and 57% of those on liraglutide. The mean fasting plasma glucose concentration at the end of the trial was similar for IDegLira (5.7 mmol/l) and insulin degludec (6.0 mmol/l), but higher for liraglutide (7.3 mmol/l). At 52 weeks, the daily insulin dose was 37% lower with IDegLira (39 units) than with insulin degludec (62 units). IDegLira was associated with a significantly greater decrease in body weight (estimated treatment difference, −2.80 kg, p < 0.0001) and a 37% lower rate of hypoglycaemia compared with insulin degludec. Overall, all treatments were well tolerated and no new adverse events or tolerability issues were observed for IDegLira.
Conclusions
These 12‐month data, derived from a 26‐week extension of the DUAL I trial, confirm the initial 26‐week main phase results and the sustainability of the benefits of IDegLira compared with its components in glycaemic efficacy, safety and tolerability.
The first low-energy Coulomb-excitation measurement of the radioactive, semi-magic, two proton-hole nucleus 206Hg, was performed at CERN's recently-commissioned HIE-ISOLDE facility. Two γ rays ...depopulating low-lying states in 206Hg were observed. From the data, a reduced transition strength B(E2;21+→01+)=4.4(6) W.u. was determined, the first such value for an N=126 nucleus south of 208Pb, which is found to be slightly lower than that predicted by shell-model calculations. In addition, a collective octupole state was identified at an excitation energy of 2705 keV, for which a reduced B(E3) transition probability of 30−13+10 W.u. was extracted. These results are crucial for understanding both quadrupole and octupole collectivity in the vicinity of the heaviest doubly-magic nucleus 208Pb, and for benchmarking a number of theoretical approaches in this key region. This is of particular importance given the paucity of data on transition strengths in this region, which could be used, in principle, to test calculations relevant to the astrophysical r-process.
We report high-precision mass measurements of ^{50-55}Sc isotopes performed at the LEBIT facility at NSCL and at the TITAN facility at TRIUMF. Our results provide a substantial reduction of their ...uncertainties and indicate significant deviations, up to 0.7 MeV, from the previously recommended mass values for ^{53-55}Sc. The results of this work provide an important update to the description of emerging closed-shell phenomena at neutron numbers N=32 and N=34 above proton-magic Z=20. In particular, they finally enable a complete and precise characterization of the trends in ground state binding energies along the N=32 isotone, confirming that the empirical neutron shell gap energies peak at the doubly magic ^{52}Ca. Moreover, our data, combined with other recent measurements, do not support the existence of a closed neutron shell in ^{55}Sc at N=34. The results were compared to predictions from both ab initio and phenomenological nuclear theories, which all had success describing N=32 neutron shell gap energies but were highly disparate in the description of the N=34 isotone.
The first implementation of the AGATA spectrometer consisting of five triple germanium detector clusters has been installed at Laboratori Nazionali di Legnaro, INFN. This setup has two major goals, ...the first one is to validate the
γ
-
tracking
concept and the second is to perform an experimental physics program using the stable beams delivered by the Tandem–PIAVE-ALPI accelerator complex. A large variety of physics topics will be addressed during this campaign, aiming to investigate both neutron and proton-rich nuclei. The setup has been designed to be coupled with the large-acceptance magnetic-spectrometer PRISMA. Therefore, the in-beam prompt
γ
rays detected with AGATA will be measured in coincidence with the products of multinucleon-transfer and deep-inelastic reactions measured by PRISMA. Moreover, the setup is versatile enough to host ancillary detectors, including the heavy-ion detector DANTE, the
γ
-
ray
detector array HELENA, the Cologne plunger for lifetime measurements and the Si-pad telescope TRACE. In this paper the design, characteristics and performance figures of the setup will be described.