Endovascular embolization is typically reserved as an adjuvant therapy in the management of cerebral arteriovenous malformations (AVMs), either for preoperative devascularization or preradiosurgical ...volume reduction. Curative embolization plays a limited role in AVM treatment but several studies have shown that it is possible, especially with later-generation liquid embolic agents. Given the complexity of AVM anatomy and the recent controversies over the role of any intervention in AVM management, it is critical that the cerebrovascular community better define the indications of each treatment modality to provide quality AVM management. In this review, the authors evaluate the role of curative AVM embolization. Important considerations in the feasibility of curative AVM embolization include whether it can be performed reliably and safely, and whether it is a durable cure. Studies over the past 20 years have begun to define the anatomical factors that are amenable to complete endovascular occlusion, including size, feeding artery anatomy, AVM morphology, and endovascular accessibility. More recent studies have shown that highly selected patients with AVMs can be treated with curative intent, leading to occlusion rates as high as 100% of such prospectively identified lesions with minimal morbidity. Advances in endovascular technology and techniques that support the efficacy and safety of curative embolization are discussed, as is the importance of superselective diagnostic angiography. Finally, the durability of curative embolization is analyzed. Overall, while still unproven, endovascular embolization has the potential to be a safe, effective, and durable curative treatment for select AVMs, broadening the armamentarium with which one can treat this disease.
OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is ...inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.
The literature on spinal vascular malformations contains a great deal of confusing terminology. Some of the nomenclature is inconsistent with the lesions described. Based on the experience of the ...senior author (R.F.S.) in the treatment of more than 130 spinal cord vascular lesions and based on a thorough review of the relevant literature, the authors propose a modified classification system for spinal cord vascular lesions. Lesions are divided into three primary or broad categories: neoplasms, aneurysms, and arteriovenous lesions. Neoplastic vascular lesions include hemangioblastomas and cavernous malformations, both of which occur sporadically and familially. The second category consists of spinal aneurysms, which are rare. The third category, spinal cord arteriovenous lesions, is divided into arteriovenous fistulas and arteriovenous malformations (AVMs). Arteriovenous fistulas are subdivided into those that are extradural and those that are intradural, with intradural lesions categorized as either dorsal or ventral. Arteriovenous malformations are subdivided into extradural-intradural and intradural malformations. Intradural lesions are further divided into intramedullary, intramedullary-extramedullary, and conus medullaris, a new category of AVM. This modified classification system for vascular lesions of the spinal cord, based on pathophysiology, neuroimaging features, intraoperative observations, and neuroanatomy, offers several advantages. First, it includes all surgical vascular lesions that affect the spinal cord. Second, it guides treatment by classifying lesions based on location and pathophysiology. Finally, it eliminates the confusion produced by the multitude of unrelated nomenclatural terms found in the literature.
Carotid stenosis is currently treated by carotid endarterectomy (CEA), carotid artery stenting (CAS), or transcarotid artery revascularization (TCAR). This study sought to add to the literature by ...providing real-world data comparing the safety and effectiveness associated with the performance of these carotid revascularization techniques by dual-trained neurosurgeons.
The authors performed a retrospective review of carotid stenosis databases at two US centers. Patients treated by CEA, transfemoral CAS, or TCAR for atherosclerotic carotid artery disease were included. Clinical outcomes were compared at 30 days after the procedure.
Seven hundred eighty patients were included (583 with CAS, 165 with CEA, and 32 with TCAR). Overall, 486 patients (62.3%) were men, and 393 (50.4%) had left-sided carotid stenosis. Most patients (n = 617, 79.1%) had symptomatic disease. Among the three treatment groups, there were no statistically significant differences with respect to 30-day ischemic events (CAS 3.8%, CEA 1.8%, TCAR 6.3%; p = 0.267) or 30-day mortality rates (CAS 3.6%, CEA 2.4%, TCAR 3.1%; p = 0.857). Male sex had significantly lower odds of 30-day transient ischemic attack (TIA) or stroke in both univariable (p = 0.024) and multivariable (p = 0.023) regression models. Increasing age had significantly higher odds of 30-day mortality on univariable (p = 0.006) and multivariable (p = 0.003) regression. Patients with the occurrence of 30-day TIA or stroke also had significantly higher odds of 30-day mortality on univariable (p < 0.001) and multivariable (p < 0.001) regression.
This real-world experience reflects the current practice of hybrid neurosurgery at two high-volume tertiary care centers and suggests that all three treatment modalities have comparable safety and effectiveness if patients are properly selected.
Background: Comaneci (Rapid Medical) is a compliant, adjustable mesh that provides temporary scaffolding during coiling of wide-necked intracranial aneurysms (WNAs) that preserves antegrade flow. We ...report our early multi-institutional experience with the Comaneci device in the USA. Method: We reviewed all patients with WNAs that were treated using the Comaneci device for coil remodeling of ruptured and unruptured aneurysms at 4 institutions between July 2019 and May 2020. Clinical characteristics, angiographic variables, and endovascular results were assessed. Results: A total of 26 patients were included (18 women). The mean age was 62.7 years (range 44–81). Fifteen patients presented with ruptured aneurysms and 11 with unruptured aneurysms. The mean aneurysm neck width was 3.91 mm (range 1.9–6.5) with a mean dome-to-neck ratio of 1.57 (range 0.59–3.39). The mean maximum width was 5.80 mm (range 3.0–9.9) and the mean maximum height was 5.61 mm (range 2.0–11.8). Successful aneurysm occlusion was achieved in 25 of 26 patients. Complete occlusion was achieved in 16 patients, near-complete occlusion was observed in 9 patients, and 1 patient demonstrated residual filling. The mean time of device exposure was 24 min (range 8–76). No vasospasm was observed at the device location. Clot formation on the device was noted in 2 separate cases, but there were no clinical sequelae. There was 1 intraprocedural complication in a case that involved the simultaneous use of 2 Comaneci devices. Conclusions: Our initial experience shows that the Comaneci device is a promising and reliable tool that can safely support coil remodeling of WNAs.
Vascular anatomy of the spinal cord Santillan, Alejandro; Nacarino, Veronica; Greenberg, Edward ...
Journal of neurointerventional surgery,
01/2012, Letnik:
4, Številka:
1
Journal Article
Recenzirano
In this article, a detailed description of the normal arterial supply and venous drainage of the spinal cord is provided, and the role of catheter angiography and MR angiography in depicting the ...vascular anatomy of the spinal cord is discussed.
The choice of anesthesia type (general anesthesia GA vs nongeneral anesthesia non-GA) in middle meningeal artery embolization (MMAE) procedures for chronic subdural hematomas (cSDH) differs between ...institutions and left to care team discretion given lack of standard guidelines. We compare the outcomes of GA vs non-GA in MMAE.
Consecutive patients receiving MMAE for cSDH at 14 North American centers (2018-2023) were included. Clinical, cSDH characteristics, and technical/clinical outcomes were compared between the GA/non-GA groups. Using propensity score matching (PSM), patients were matched controlling for age, baseline modified Rankin Scale, concurrent/prior surgery, hematoma thickness/midline shift, and baseline antiplatelet/anticoagulation. The primary end points included surgical rescue and radiographic success rates (≥50% reduction in maximum hematoma thickness with minimum 2 weeks of imaging). Secondary end points included technical feasibility, procedural complications, and functional outcomes.
Seven hundred seventy-eight patients (median age 73 years, 73.2% male patients) underwent 956 MMAE procedures, 667 (70.4%) were non-GA and 280 were GA (29.6%). After running 1:3 PSM algorithm, this resulted in 153 and 296 in the GA and non-GA groups, respectively. There were no baseline/procedural differences between the groups except radial access more significantly used in the non-GA group (P = .001). There was no difference between the groups in procedural technical feasibility, complications rate, length of stay, surgical rescue rates, or favorable functional outcome at the last follow-up. Subsequent 1:1 sensitivity PSM retained the same results. Bilateral MMAE procedures were more performed under non-GA group (75.8% vs 67.2%; P = .01); no differences were noted in clinical/radiographic outcomes between bilateral vs unilateral MMAE, except for longer procedure duration in the bilateral group (median 73 minutes IQR 48.3-100 vs 54 minutes 39-75; P < .0001). Another PSM analysis comparing GA vs non-GA in patients undergoing stand-alone MMAE retained similar associations.
We found no significant differences in radiological improvement/clinical outcomes between GA and non-GA for MMAE.
The authors report on an 81-year-old woman with a pathologic hangman's fracture secondary to a complex arteriovenous fistula (AVF). The patient presented with severe, unremitting neck pain and was ...found to have fractures bilaterally through the pars interarticularis of C-2 with significant anterior subluxation of C-2 over C-3 along with widening of the left transverse foramen. Due to an abnormally appearing left vertebral artery (VA) on CT angiography, the patient underwent conventional angiography, which revealed a complex AVF stemming from the left VA at the level of C-2 with dilated posterior cervical veins and a large venous varix. Given the radiographic evidence of bone remodeling and the chronicity of the AVF, it is believed that the C-2 vertebra was weakened over time by the pulsatile and compressive force of the vascular malformation eventually leading to fracture with minimal stress. Coil embolization of the AVF was performed followed by surgical fixation of C-1 to C-4. This case highlights the importance of investigating an underlying disease process in patients who present with significant spinal fractures in the absence of trauma.