Atrioventricular (AV) conduction impairment is well described after surgical aortic valve replacement, but little is known in patients undergoing transcatheter aortic valve implantation (TAVI). We ...assessed AV conduction and need for a permanent pacemaker in patients undergoing TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards Sapien Valve (ESV). Sixty-seven patients without pre-existing permanent pacemaker were included in the study. Forty-one patients (61%) and 26 patients (39%) underwent successful TAVI with the MCRS and ESV, respectively. Complete AV block occurred in 15 patients (22%), second-degree AV block in 4 (6%), and new left bundle branch block in 15 (22%), respectively. A permanent pacemaker was implanted in 23 patients (34%). Overall PR interval and QRS width increased significantly after the procedure (p <0.001 for the 2 comparisons). Implantation of the MCRS compared to the ESV resulted in a trend toward a higher rate of new left bundle branch block and complete AV block (29% vs 12%, p = 0.09 for the 2 comparisons). During follow-up, complete AV block resolved in 64% of patients. In multivariable regression analysis pre-existing right bundle branch block was the only independent predictor of complete AV block after TAVI (relative risk 7.3, 95% confidence interval 2.4 to 22.2). In conclusion, TAVI is associated with impairment of AV conduction in a considerable portion of patients, patients with pre-existing right bundle branch block are at increased risk of complete AV block, and complete AV block resolves over time in most patients.
This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point.
One hundred fifty patients (57±10 years) ...underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43-73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070-7.143; P<0.001), left atrial diameter≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078-4.016; P=0.03), continuous AF duration≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024-3.846; P<0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037-3.388; P=0.04) predicted arrhythmia recurrence.
In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.
Several studies found that patients with atrial fibrillation (AF) have an increased risk of cognitive decline and dementia over time. However, the magnitude of the problem, associated risk factors ...and underlying mechanisms remain unclear.
This article describes the design and methodology of the Swiss Atrial Fibrillation (Swiss-AF) Cohort Study, a prospective multicentre national cohort study of 2400 patients across 13 sites in Switzerland. Eligible patients must have documented AF. Main exclusion criteria are the inability to provide informed consent and the presence of exclusively short episodes of reversible forms of AF. All patients undergo extensive phenotyping and genotyping, including repeated assessment of cognitive functions, quality of life, disability, electrocardiography and cerebral magnetic resonance imaging. We also collect information on health related costs, and we assemble a large biobank. Key clinical outcomes in Swiss-AF are death, stroke, systemic embolism, bleeding, hospitalisation for heart failure and myocardial infarction. Information on outcomes and updates on other characteristics are being collected during yearly follow-up visits.
Up to 7 April 2017, we have enrolled 2133 patients into Swiss-AF. With the current recruitment rate of 15 to 20 patients per week, we expect that the target sample size of 2400 patients will be reached by summer 2017.
Swiss-AF is a large national prospective cohort of patients with AF in Switzerland. This study will provide important new information on structural and functional brain damage in patients with AF and on other AF related complications, using a large variety of genetic, phenotypic and health economic parameters.
Endurance athletes have an increased risk of developing atrial fibrillation (AF) at 40 to 50 years of age. Signal-averaged P-wave analysis has been used for identifying patients at risk for AF. We ...evaluated the impact of lifetime training hours on signal-averaged P-wave duration and modifying factors. Nonelite men athletes scheduled to participate in the 2010 Grand Prix of Bern, a 10-mile race, were invited. Four hundred ninety-two marathon and nonmarathon runners applied for participation, 70 were randomly selected, and 60 entered the final analysis. Subjects were stratified according to their lifetime training hours (average endurance and strength training hours per week × 52 × training years) in low (<1,500 hours), medium (1,500 to 4,500 hours), and high (>4,500 hours) training groups. Mean age was 42 ± 7 years. From low to high training groups signal-averaged P-wave duration increased from 131 ± 6 to 142 ± 13 ms (p = 0.026), and left atrial volume increased from 24.8 ± 4.6 to 33.1 ± 6.2 ml/m2 (p = 0.001). Parasympathetic tone expressed as root of the mean squared differences of successive normal-to-normal intervals increased from 34 ± 13 to 47 ± 16 ms (p = 0.002), and premature atrial contractions increased from 6.1 ± 7.4 to 10.8 ± 7.7 per 24 hours (p = 0.026). Left ventricular mass increased from 100.7 ± 9.0 to 117.1 ± 18.2 g/m2 (p = 0.002). Left ventricular systolic and diastolic function and blood pressure at rest were normal in all athletes and showed no differences among training groups. Four athletes (6.7%) had a history of paroxysmal AF, as did 1 athlete in the medium training group and 3 athletes in the high training group (p = 0.252). In conclusion, in nonelite men athletes lifetime training hours are associated with prolongation of signal-averaged P-wave duration and an increase in left atrial volume. The altered left atrial substrate may facilitate occurrence of AF. Increased vagal tone and atrial ectopy may serve as modifying and triggering factors.
Atrial fibrillation may be clearly symptomatic and is easily amenable to state-of-the-art treatment, most importantly oral anticoagulation therapy for the prevention of thromboembolism. However, ...atrial fibrillation may also go unnoticed for long periods in many patients. This silent or subclinical atrial fibrillation is nevertheless associated with thromboembolic risk just like clinically evident atrial fibrillation. Early detection of atrial fibrillation in patients at increased thromboembolic risk and consequent oral anticoagulation therapy may have a significant impact on public health. This review focuses on screening recommendations for atrial fibrillation and on the impact of silent atrial fibrillation in various clinical scenarios.
Abstract
Aims
Leadless cardiac pacemaker (PM) implantation differs from conventional PM implantation. While the procedure has been considered safe, recent real-world data raised concerns about the ...learning curve of new operators and their implantation quality. The goal of this study was to investigate the influence of the first operator’s experience on leadless PM implantation quality and procedural efficiency.
Methods and results
We performed a bicentric analysis of all Micra TPS™ implantations in two large tertiary referral hospitals. We assessed both leadless PM implantation quality based on the absence of complications (requiring intervention or prolonged hospitalization), good electrical performance (pacing threshold ≤ 1.5 V/0.24 ms, R-wave amplitude > 5 mV), and acceptable fluoroscopy duration (<10 min) as well as procedural efficiency in relation to the operator’s experience. Univariate and multivariate logistic regression analyses were performed to identify predictors for implantation quality and procedural efficiency. Leadless PM implantation was successful in 106/111 cases (95.5%). Three patients (2.7%) experienced acute complications (one cardiac tamponade, one femoral bleeding, one posture-related PM exit block). Multivariate analysis showed that implantation quality of more experienced first operators was higher odds ratio 1.09 (95% confidence interval 1.00–1.19), P = 0.05. Procedural efficiency increased with operator experience as evidenced by an inverse correlation of procedure time, time to the first deployment, fluoroscopy time, and the number of procedures performed (all P < 0.05).
Conclusion
The operator’s learning curve is a critical factor for leadless PM implantation quality and procedural efficiency.
We observed a case of conductor externalization in a Biotronik Linox lead.
The purpose of this study was to investigate lead performance of the Linox lead and the identical Sorin Vigila lead and ...prevalence of conductor externalization.
We compared lead performance of all Linox and Vigila leads implanted at our center (BL group; n = 93) with that of all Boston Scientific Endotak Reliance leads (ER group; n = 190) and Medtronic Sprint Quattro leads (SQ group; n = 202) implanted during the same period. We screened all patients in the BL group for conductor externalization.
We identified 8 cases of lead failures in the BL group (index case of conductor externalization, 6 cases of nonphysiological high-rate sensing, and 1 case of high-voltage conductor fracture). Prospective fluoroscopic screening of 98% of all active BL group cases revealed 1 additional case of conductor externalization. The median follow-up was 41, 27, and 29 months for the BL group, ER group, and SQ group, respectively; lead survival was 94.9%, 99.2%, and 100% at 3 years and 88%, 97.5%, and 100% at 5 years (P = .038 for BL group vs ER group and P = .007 for BL group vs SQ group using the log-rank test). Younger age at implant was an independent predictor of lead failure in the BL group (adjusted hazard ratio 0.85; 95% confidence interval 0.77-0.94; P = .001).
At our center, survival of the Linox lead is 88% at 5 years and significantly worse than that of other leads. Conductor externalization is present in a minority of failed Linox leads. Younger age at implant is an independent predictor of Linox lead failure.
Objectives We evaluated the feasibility and safety of epicardial substrate elimination with endocardial radiofrequency (RF) delivery in patients with scar-related ventricular tachycardia (VT). ...Background Epicardial RF delivery is limited by fat or associated with bleeding, extra-cardiac damages, coronary vessels and phrenic nerve injury. Alternative ablation approaches might be desirable. Methods Forty-six patients (18 ischemic cardiomyopathy ICM, 13 nonischemic dilated cardiomyopathy NICM, 15 arrhythmogenic right ventricular cardiomyopathy ARVC) with sustained VT underwent combined endo- and epicardial mapping. All patients received endocardial ablation targeting local abnormal ventricular activities in the endocardium (Endo-LAVA) and epicardium (Epi-LAVA), followed by epicardial ablation if needed. Results From a total of 173 endocardial ablations targeting Epi-LAVA at the facing site, 48 (28%) applications (ICM: 20 of 71 28%, NICM: 3 of 39 8%, ARVC: 25 of 63 40%) successfully eliminated the Epi-LAVA. Presence of Endo-LAVA, the most delayed and low bipolar amplitude of Epi-LAVA, low unipolar amplitude in the facing endocardium, and Epi-LAVA within a wall thinning area at computed tomography scan were associated with successful ablation. Endocardial ablation could abolish all Epi-LAVA in 4 ICM and 2 ARVC patients, whereas all patients with NICM required epicardial ablation. Endocardial ablation was able to eliminate Epi-LAVA at least partially in 15 (83%) ICM, 2 (13%) NICM, and 11 (73%) ARVC patients, contributing to a potential reduction in epicardial RF applications. Pericardial bleeding occurred in 4 patients with epicardial ablation. Conclusions Elimination of Epi-LAVA with endocardial RF delivery is feasible and might be used first to reduce the risk of epicardial ablation.