The CDEX-1 experiment conducted a search of low-mass (< 10GeV/c super(2)) weakly interacting massive particles dark matter at the China Jinping Underground Laboratory using a p-type point-contact ...germanium detector with a fiducial mass of 915 g at a physics analysis threshold of 475 eVee. We report the hardware setup, detector characterization, data acquisition, and analysis procedures of this experiment. No excess of unidentified events is observed after the subtraction of the known background. Using 335.6 kg-days of data, exclusion constraints on the weakly interacting massive particle-nucleon spin-independent and spin-dependent couplings are derived.
Curcumin has been attributed with antioxidant, anti-inflammatory, antibacterial activities, and has shown highly protective effects against enteropathogenic bacteria and mycotoxins. Ochratoxin A ...(OTA) is one of the major intestinal pathogenic mycotoxins. The possible effect of curcumin on the alleviation of enterotoxicity induced by OTA is unknown. The effects of dietary curcumin supplementation on OTA-induced oxidative stress, intestinal barrier and mitochondrial dysfunctions were examined in young ducks. A total of 540 mixed-sex 1-day-old White Pekin ducklings with initial BW (43.4±0.1 g) were randomly assigned into controls (fed only the basal diet), a group fed an OTA-contaminated diet (2 mg/kg feed), and a group fed the same OTA-contaminated feed plus 400 mg/kg of curcumin. Each treatment consisted of six replicates, each containing 30 ducklings and treatment lasted for 21 days. There was a significant decrease in average daily gain (ADG) and increased feed : gain caused by OTA (P<0.05); curcumin co-treatment prevented the decrease in BW and ADG compared with the OTA group (P<0.05). Histopathological and ultrastructural examination showed clear signs of enterotoxicity caused by OTA, but these changes were largely prevented by curcumin supplementation. Curcumin decreased the concentrations of interleukin-1β, tumor necrosis factor-α and malondialdehyde, and increased the activity of glutathione peroxidase induced by OTA in the jejunal mucosa of ducks (P<0.05). Additionally, curcumin increased jejunal mucosa occludin and tight junction protein 1 mRNA and protein levels, and decreased those of ρ-associated protein kinase 1 (P<0.05). Notably, curcumin inhibited the increased expression of apoptosis-related genes, and downregulated mitochondrial transcription factors A, B1 and B2 caused by OTA without any effects on RNA polymerase mitochondrial (P<0.05). These results indicated that curcumin could protect ducks from OTA-induced impairment of intestinal barrier function and mitochondrial integrity.
A white neutron beam line using back-streaming neutrons from the spallation target is under construction at China Spallation Neutron Source (CSNS). Different spectrometers, to be installed in the ...so-called Back-n beam line for nuclear data measurements, are also being developed in phases. The physical design of the beam line is carried out with the help of a complicated collimation system and a sophisticated neutron dump, taking the overview of the neutron beam characteristics into account. This includes energy spectrum, flux and time structure, the optimizations of neutron beam spots and in-hall background. The wide neutron energy range of 1eV-100MeV is excellent for supporting different applications, especially nuclear data measurements. At Endstation#2, which is about 80m away from the target, the main properties of the beam line include neutron flux of 10
n/cm
/s, time resolution of a few per mille over nearly the entire energy range, and in-hall background of about 0.01/cm
/s for both neutron and gamma. With its first commission in late 2017, Back-n will not only be the first high-performance white neutron source in China, but also one of the best white neutron sources in the world.
We report new limits on a spin-independent weakly interacting massive particle (WIMP)-nucleon interaction cross section using 39.5 kg days of data taken with a p-type point-contact germanium detector ...of 840 g fiducial mass at the Kuo-Sheng Reactor Neutrino Laboratory. Crucial to this study is the understanding of the selection procedures and, in particular, the bulk-surface events differentiation at the sub-keV range. The signal-retaining and background-rejecting efficiencies were measured with calibration gamma sources and a novel n-type point-contact germanium detector. Part of the parameter space in the cross section versus WIMP-mass implied by various experiments is probed and excluded.
Germanium ionization detectors with sensitivities as low as 100eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are ...summarized. The detectors have to measure physics signals whose amplitude is comparable to that of pedestal electronic noise. To fully exploit this new detector technique, various experimental issues including quenching factors, energy reconstruction and calibration, signal triggering and selection as well as evaluation of their associated efficiencies have to be attended. The efforts and results of a research program to address these challenges are presented.