A liquid argon time projection chamber, constructed for the Argon Response to Ionization and Scintillation (ARIS) experiment, is exposed to the highly collimated and quasimonoenergetic LICORNE ...neutron beam at the Institut de Physique Nucléaire d’Orsay (IPNO) in order to study the scintillation response to nuclear and electronic recoils. An array of liquid scintillator detectors, arranged around the apparatus, tag scattered neutrons and select nuclear recoil energies in the 7, 120 keV energy range. The relative scintillation efficiency of nuclear recoils is measured to high precision at null field, and the ion-electron recombination probability is extracted for a range of applied electric fields. Single-scattered Compton electrons, produced by gammas emitted from the deexcitation of Li*7 in coincidence with the beam pulse, along with calibration gamma sources, are used to extract the recombination probability as a function of energy and electron drift field. The ARIS results are compared with three recombination probability parametrizations (Thomas-Imel, Doke-Birks, and PARIS), allowing for the definition of a fully comprehensive model of the liquid argon response to nuclear and electronic recoils down to the few-keV range. The constraints provided by ARIS to the liquid argon response at low energy allow the reduction of systematics affecting the sensitivity of dark matter search experiments based on liquid argon.
The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be ...affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. In this work, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei ...with an effective field theory framework. The dataset corresponds to a total (16660 \(\pm\) 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between \(2.4 \times 10^{-45} \, \mathrm{cm}^2\) and \(2.3 \times 10^{-42} \, \mathrm{cm}^2\) (8.9 \(\times 10^{-45} \, \mathrm{cm}^2\) and 6.0 \(\times 10^{-42} \, \mathrm{cm}^2\)) for WIMPs of mass of 100 \(\mathrm{GeV/c^2}\) (1000 \(\mathrm{GeV/c^2}\)) at 90\% confidence level.
We report measurements of the charged daughter fraction of \(^{218}\)Po as a result of the \(^{222}\)Rn alpha decay, and the mobility of \(^{218}\)Po\(^+\) ions, using radon-polonium coincidences ...from the \(^{238}\)U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of \(^{218}\)Po that is charged is found to be 0.37\(\pm\)0.03 and the mobility of \(^{218}\)Po\(^+\) is (8.6\(\pm\)0.1)\(\times\)10$^{-4}$$\frac{\text{cm}^2}{\text{Vs}}$.
A liquid argon time projection chamber, constructed for the Argon Response to Ionization and Scintillation (ARIS) experiment, has been exposed to the highly collimated and quasi-monoenergetic LICORNE ...neutron beam at the Institute de Physique Nuclaire Orsay in order to study the scintillation response to nuclear and electronic recoils. An array of liquid scintillator detectors, arranged around the apparatus, tag scattered neutrons and select nuclear recoil energies in the 7, 120 keV energy range. The relative scintillation efficiency of nuclear recoils was measured to high precision at null field, and the ion-electron recombination probability was extracted for a range of applied electric fields. Single Compton scattered electrons, produced by gammas emitted from the de-excitation of \(^7\)Li* in coincidence with the beam pulse, along with calibration gamma sources, are used to extract the recombination probability as a function of energy and electron drift field. The ARIS results have been compared with three recombination probability parameterizations (Thomas-Imel, Doke-Birks, and PARIS), allowing for the definition of a fully comprehensive model of the liquid argon response to nuclear and electronic recoils down to a few keV range. The constraints provided by ARIS to the liquid argon response at low energy allow the reduction of systematics affecting the sensitivity of dark matter search experiments based on liquid argon
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 ...V/cm, 150 V/cm, and 200 V/cm using high statistics \(^{39}\)Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 \(\pm\) 0.04) cm\(^2\)/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 \(\pm\) 0.09) cm\(^2\) /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light ...signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.
This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive ...sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.
Measurements were made of scintillation light yield of alpha particles from the \(^{222}\)Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to ...increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.