We have measured the radiation tolerance of poly-crystalline and single-crystalline diamonds grown by the chemical vapor deposition (CVD) process by measuring the charge collected before and after ...irradiation in a 50 m pitch strip detector fabricated on each diamond sample. We irradiated one group of sensors with 800 MeV protons, and a second group of sensors with 24 GeV protons, in steps, to protons cm−2 and protons cm−2 respectively. We observe the sum of mean drift paths for electrons and holes for both poly-crystalline CVD diamond and single-crystalline CVD diamond decreases with irradiation fluence from its initial value according to a simple damage curve characterized by a damage constant for each irradiation energy and the irradiation fluence. We find for each irradiation energy the damage constant, for poly-crystalline CVD diamond to be the same within statistical errors as the damage constant for single-crystalline CVD diamond. We find the damage constant for diamond irradiated with 24 GeV protons to be and the damage constant for diamond irradiated with 800 MeV protons to be . Moreover, we observe the pulse height decreases with fluence for poly-crystalline CVD material and within statistical errors does not change with fluence for single-crystalline CVD material for both 24 GeV proton irradiation and 800 MeV proton irradiation. Finally, we have measured the uniformity of each sample as a function of fluence and observed that for poly-crystalline CVD diamond the samples become more uniform with fluence while for single-crystalline CVD diamond the uniformity does not change with fluence.
FOOT (FragmentatiOn Of Target) is an applied nuclear physics experiment conceived to conduct high-precision cross section measurements of nuclear fragmentation processes relevant for particle therapy ...and radiation protection in space. These measurements are important to estimate the physical and biological effects of nuclear fragments, which are produced when energetic particle beams penetrate human tissue.
A component of the FOOT experiment is the ΔE-TOF system. It is designed to measure energy loss and time-of-flight of nuclear fragments produced in particle collisions in thin targets in order to extract their charge and velocity. The ΔE-TOF system is composed of a start counter, providing the start time for the time-of-flight, and a 40 × 40 cm2 wall of thin plastic scintillator bars, providing the arrival time and energy loss of the fragments passing through the detector. Particle charge discrimination can be achieved by correlating the energy loss in the scintillator bars with the measured time-of-flight.
Recently, we have built a full-size ΔE-TOF detector. In this work, we describe the energy and time-of-flight calibration procedure and assess the performance of this system. We use data acquired during beam tests at CNAO with proton and 12C beams and at GSI with 16O beams in the energy range relevant for particle therapy, i.e., from 60 to 400 MeV/u. For heavy fragments (C and O), we obtain energy and time resolutions ranging from 4.0 to 5.2% and from 54 to 76 ps, respectively. The procedure is also applied to a fragmentation measurement of a 400 MeV/u 16O beam on a 5 mm carbon target, showing that the system is able to discriminate the charges of impinging fragments.
This paper aims at exploring and validating the adoption of standard fabrication processes for the realization of CMOS active pixel sensors, for particle detection purposes. The goal is to implement ...a single-chip, complete radiation sensor system, including on a CMOS integrated circuit the sensitive devices, read-out and signal processing circuits. A prototype chip (RAPS01) based on these principles has been already fabricated, and a chip characterization has been carried out; in particular, the evaluation of the sensitivity of the sensor response on the actual operating conditions was estimated, as well as the response uniformity. Optimization and tailoring of the sensor structures for High Energy Physics applications are being evaluated in the design of the next generation chip (RAPS02). Basic features of the new chip includes digitally configurable readout and multi-mode access (i.e., either sparse of line-scan readout).
First result on biased CMOS MAPs-on-diamond devices Kanxheri, K.; Citroni, M.; Fanetti, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2015, Letnik:
796
Journal Article
Recenzirano
Odprti dostop
Recently a new type of device, the MAPS-on-diamond, obtained bonding a thinned to 25μm CMOS Monolithic Active Pixel Sensor to a standard 500μm pCVD diamond substrate, has been proposed and ...fabricated, allowing a highly segmented readout (10×10μm pixel size) of the signal produced in the diamond substrate. The bonding between the two materials has been obtained using a new laser technique to deliver the needed energy at the interface. A biasing scheme has been adopted to polarize the diamond substrate to allow the charge transport inside the diamond without disrupting the functionalities of the CMOS Monolithic Active Pixel Sensor.
The main concept of this class of devices is the capability of the charges generated in the diamond by ionizing radiation to cross the silicon–diamond interface and to be collected by the MAPS photodiodes. In this work we demonstrate that such passage occurs and measure its overall efficiency. This study has been carried out first calibrating the CMOS MAPS with monochromatic X-rays, and then testing the device with charged particles (electrons) either with and without biasing the diamond substrate, to compare the amount of signal collected.
Interventional radiologists and staff members, during all their professional activities, are frequently exposed to protracted and fractionated low doses of ionizing radiation. Due to skin tissues and ...peripheral blood irradiation, these exposures can result in deterministic effects (radiodermatitis, aged skin, and hand depilation) or stochastic ones (skin and non-solid cancer incidence). The authors present a novel approach to perform online monitoring of the staff during their interventions by using a device based on an Active Pixel Sensor. The performance of the sensor as an X-ray radiation detector has been evaluated with a proper experimental setup: the number of photons and the generated charge have been assessed as dosimetric observables from the frames acquired by the sensor using a two-threshold clustering algorithm, the efficiency of which has been evaluated as well. The correlation of these observables with passive dosimeter dose measurements has been analyzed: a good linearity has been demonstrated, and the response difference between pulsed and continuous operational modes is reduced to less than 10%, marking a distinct improvement with respect to commercial Active Personal Dosimeters.
Diamond detector technology, status and perspectives Alexopoulos, A.; Artuso, M.; Bachmair, F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2019, Letnik:
924, Številka:
C
Journal Article
Recenzirano
Odprti dostop
Detectors based on Chemical Vapor Deposition (CVD) diamond have been used extensively and successfully in beam conditions/beam loss monitors as the innermost detectors in the highest radiation areas ...of Large Hadron Collider (LHC) experiments. The startup of the LHC in 2015 brought a new milestone where the first polycrystalline CVD (pCVD) diamond pixel modules were installed in an LHC experiment and successfully began operation. The RD42 collaboration at CERN is leading the effort to develop polycrystalline CVD diamond as a material for tracking detectors operating in extreme radiation environments. The status of the RD42 project with emphasis on recent beam test results is presented.
•Successful operation of the first pCVD diamond planar pixel detector in the ATLAS experiment at the LHC.•Demonstration that the average signal pulse height of pCVD diamond detectors irradiated up to 5×014n∕cm2 is independent of the particle flux up to ∼20 MHz/cm2.•Successful fabrication and operation of the first pCVD diamond 3D pixel detector with 50 micron × 50 micron cells read out with CMS pixel electronics with 3 cell × 2 cell ganging into pixels to match the electronics.•Demonstration that in the pCVD diamond 3D pixel device the efficiency for a MIP was 99% when operating with a 1500 e threshold.
Radiation tolerance of diamond detectors Bäni, L; Artuso, M; Bachmair, F ...
Journal of physics. Conference series,
11/2022, Letnik:
2374, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Diamond is used as detector material in high energy physics experiments due to its inherent radiation tolerance. The RD42 collaboration has measured the radiation tolerance of chemical vapour ...deposition (CVD) diamond against proton, pion, and neutron irradiation. Results of this study are summarized in this article. The radiation tolerance of diamond detectors can be further enhanced by using a 3D electrode geometry. We present preliminary results of a poly-crystalline CVD (pCVD) diamond detector with a 3D electrode geometry after irradiation and compare to planar devices of roughly the same thickness.
Chemical Vapour Deposition (CVD) diamond is being considered as a material for particle detectors in a harsh radiation environment. This article presents beam test results of 3D pixel detectors ...fabricated with poly-crystalline CVD diamonds. The cells of the devices had a size of 50µm×50µm with columns 2.6µm in diameter. The cells were ganged in a 3×2 and 5×1 pattern to match the layouts of the pixel read-out electronics currently used in the CMS and ATLAS experiments at the Large Hadron Collider, respectively. In beam tests, using tracks reconstructed with a high precision tracking telescope, a tracking efficiency of 99.3% was achieved. The efficiency of both devices plateaus at a bias voltage of 30V. Also irradiated poly-crystalline CVD diamond pad detectors were investigated. In high rate beam tests with particle fluxes up to 20MHz/cm2 and irradiations up to 8 ⋅ 1015n/cm2 it was shown that the pulse height of irradiated poly-crystalline CVD diamonds does not depend on flux to the O2%.