Clinical performance of the novel high-sensitivity cardiac troponin I (Siemens-hs-cTnI-Centaur) assay is unknown. We aimed to clinically validate the Siemens-hs-cTnI-Centaur assay and develop 0/1-h ...and 0/2-h algorithms.
We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists including all clinical information twice: first, using serial hs-cTnT (Roche-Elecsys, primary analysis); second, using hs-cTnI (Abbott-Architect, secondary analysis) measurements in addition to the clinically applied (hs)-cTn. Siemens-hs-cTnI-Centaur was measured at presentation, 1 h, and 2 h. The primary objective was a direct comparison of diagnostic accuracy, quantified by the area under the ROC curve (AUC), of Siemens-hs-cTnI-Centaur vs the 2 established hs-cTn assays (Roche-hs-cTnT-Elecsys, Abbott-hs-cTnI-Architect). Secondary objectives included the development of Siemens-hs-cTnI-Centaur-specific 0/1-h and 0/2-h algorithms.
AMI was the final diagnosis in 318 of 1755 (18%) patients (using Roche-hs-cTnT-Elecsys for adjudication). The AUC at presentation for Siemens-hs-cTnI-Centaur was 0.94 (95% CI, 0.92-0.96) and comparable with 0.95 (95% CI, 0.93-0.97) for Roche-hs-cTnT-Elecsys and 0.93 (95% CI, 0.90-0.96) for Abbott-hs-cTnI-Architect. Applying the derived Siemens-hs-cTnI-Centaur 0/1-h algorithm to the validation cohort, 46% of patients were ruled out (sensitivity, 99.1%; 95% CI, 95.3-100), and 18% of patients were ruled in (specificity, 94.1%; 95% CI, 91.8-95.9). The Siemens-hs-cTnI-Centaur 0/2-h algorithm ruled out 55% of patients (sensitivity, 100%; 95% CI, 94.1-100), and ruled in 18% of patients (specificity, 96.0%; 95% CI, 93.1-97.9). Findings were confirmed in the secondary analyses using serial measurements of Abbott-hs-cTnI-Architect for adjudication.
Diagnostic accuracy and clinical utility of the novel Siemens-hs-cTnI-Centaur assay are high and comparable with the established hs-cTn assays. ClinicalTrials.gov Identifier: NCT00470587.
Four strategies for very early rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I (hs-cTnI) have been identified. It remains unclear which strategy is most attractive ...for clinical application.
We prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. Hs-cTnI levels were measured at presentation and after 1 hour in a blinded fashion. We directly compared all 4 hs-cTnI-based rule-out strategies: limit of detection (LOD, hs-cTnI<2 ng/L), single cutoff (hs-cTnI<5 ng/L), 1-hour algorithm (hs-cTnI<5 ng/L and 1-hour change<2 ng/L), and the 0/1-hour algorithm recommended in the European Society of Cardiology guideline combining LOD and 1-hour algorithm.
Among 2828 enrolled patients, acute myocardial infarction was the final diagnosis in 451 (16%) patients. The LOD approach ruled out 453 patients (16%) with a sensitivity of 100% (95% confidence interval CI, 99.2%-100%), the single cutoff 1516 patients (54%) with a sensitivity of 97.1% (95% CI, 95.1%-98.3%), the 1-hour algorithm 1459 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%-99.2%), and the 0/1-hour algorithm 1463 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%-99.2%). Predefined subgroup analysis in early presenters (≤2 hours) revealed significantly lower sensitivity (94.2%, interaction
=0.03) of the single cutoff, but not the other strategies. Two-year survival was 100% with LOD and 98.1% with the other strategies (
<0.01 for LOD versus each of the other strategies).
All 4 rule-out strategies balance effectiveness and safety equally well. The single cutoff should not be applied in early presenters, whereas the 3 other strategies seem to perform well in this challenging subgroup.
URL: http://www.clinicaltrials.gov. Unique identifier: NCT00470587.
Abstract
Aims
We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific ...to older patients.
Methods and results
We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age <55 years (young), ≥55 to <70 years (middle-age), ≥70 years (old). Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% 95% confidence interval (95% CI) 94.9–100 in young, 99.3% (95% CI 96.0–99.9) in middle-age, and 99.3% (95% CI 97.5–99.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8–97.9) in young, 96.1% (95% CI 94.5–97.2) in middle-age, and 92.7% (95% CI 90.7–94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P < 0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P < 0.01), reduced overall efficacy for hs-cTnT (P < 0.01), while maintaining efficacy for hs-cTnI. Findings were confirmed in two validation cohorts (n = 2767).
Conclusion
While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnI.
Clinical Trial Registration
https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587 and NCT02355457 (BACC).
Uncertainties regarding the most appropriate definition and treatment of type 2 myocardial infarction (T2MI) due to supply-demand mismatch have contributed to inconsistent adoption in clinical ...practice.
This study sought a better understanding of the effect of the definition of T2MI on its incidence, treatment, and event-related mortality, thereby addressing an important unmet clinical need.
The final diagnosis was adjudicated in patients presenting with symptoms suggestive of myocardial infarction by 2 independent cardiologists by 2 methods: 1 method required the presence of coronary artery disease, a common interpretation of the 2007 universal definition (T2MI2007); and 1 method did not require coronary artery disease, the 2012 universal definition (T2MI2012).
Overall, 4,015 consecutive patients were adjudicated. The incidence of T2MI based on the T2MI2007 definition was 2.8% (n = 112). The application of the more liberal T2MI2012 definition resulted in an increase of T2MI incidence of 6% (n = 240), a relative increase of 114% (128 reclassified patients, defined as T2MI2012reclassified). Among T2MI2007, 6.3% of patients received coronary revascularization, 22% dual-antiplatelet therapy, and 71% high-dose statin therapy versus 0.8%, 1.6%, and 31% among T2MI2012reclassified patients, respectively (all p < 0.01). Cardiovascular mortality at 90 days was 0% among T2MI2012reclassified, which was similar to patients with noncardiac causes of chest discomfort (0.2%), and lower than T2MI2007 (3.6%) and type 1 myocardial infarction (T1MI) (4.8%) (T2MI2012reclassified vs. T2MI2007 and T1MI: p = 0.03 and 0.01, respectively).
T2MI2012reclassified has a substantially lower event-related mortality rate compared with T2MI2007 and T1MI. (Advantageous Predictors of Acute Coronary Syndromes Evaluation APACE Study; NCT00470587)
Display omitted
The aim of this study was to validate the clinical performance of the Beckman Access high-sensitivity cardiac troponin I (hs-cTnI) assay.
We enrolled patients presenting to the emergency department ...with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists with all clinical information including cardiac imaging twice: first, using serial hs-cTnT (Elecsys, primary analysis), and second, using hs-cTnI (Architect, secondary analysis) measurements in addition to the clinically used hs-cTn. hs-cTnI Access was measured at presentation and at 1 h. The primary objective was a direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI Access vs the hs-cTnT Elecsys and hs-cTnI Architect assays. Secondary objectives included the derivation and validation of an hs-cTnI Access-specific 0/1-h algorithm.
AMI was the adjudicated final diagnosis in 243 of 1579 (15.4%) patients. The AUC at presentation for hs-cTnI Access was 0.95 (95% CI, 0.94-0.96), higher than hs-cTnI Architect 0.92 (95% CI, 0.91-0.94;
< 0.001) and comparable to hs-cTnT Elecsys 0.94 (95% CI, 0.93-0.95;
= 0.12). Applying the derived hs-cTnI Access 0/1-h algorithm (derivation cohort n = 686) to the validation cohort (n = 680), 60% of patients were ruled out sensitivity, 98.9% (95% CI, 94.3-99.8), and 15% of patients were ruled in specificity, 95.9% (95% CI, 94.0-97.2). Patients ruled out by the 0/1-h algorithm had a survival rate of 100% at 30 days. Findings were confirmed in the secondary analyses by the adjudication including serial measurements of Architect hs-cTnI.
Diagnostic accuracy and clinical utility of the Beckman hs-cTnI Access assay are very high and at least comparable to Roche hs-cTnT and Abbott hs-cTnI assays.
NCT00470587.
The non-ST-segment-elevation myocardial infarction (NSTEMI) guidelines of the European Society of Cardiology (ESC) recommend a 3h cardiac troponin determination in patients triaged to the ...observe-zone of the ESC 0/1h-algorithm; however, no specific cutoff for further triage is endorsed. Recently, a specific cutoff for 0/3h high-sensitivity cardiac troponin T (hs-cTnT) change (7 ng/L) was proposed, warranting external validation.
Patients presenting with acute chest discomfort to the emergency department were prospectively enrolled into an international multicenter diagnostic study. Final diagnoses were centrally adjudicated by 2 independent cardiologists applying the fourth universal definition of myocardial infarction, on the basis of complete cardiac workup, cardiac imaging, and serial hs-cTnT. Hs-cTnT concentrations were measured at presentation, after 1 hour, and after 3 hours. The objective was to externally validate the proposed cutoff, and if necessary, derive and internally as well as externally validate novel 0/3h-criteria for the observe-zone of the ESC 0/1h-hs-cTnT-algorithm in an independent multicenter cohort.
Among 2076 eligible patients, application of the ESC 0/1h-hs-cTnT-algorithm triaged 1512 patients (72.8%) to either rule out or rule in NSTEMI, leaving 564 patients (27.2%) in the observe-zone (adjudicated NSTEMI prevalence, 120/564 patients, 21.3%). The suggested 0/3h-hs-cTnT-change of <7 ng/L triaged 517 patients (91.7%) toward rule-out, resulting in a sensitivity of 33.3% (95% CI, 25.5-42.2), missing 80 patients with NSTEMI, and ≥7 ng/L triaged 47 patients toward rule-in (8.3%), resulting in a specificity of 98.4% (95% CI, 96.8-99.2). Novel derived 0/3h-criteria for the observe-zone patients ruled out NSTEMI with a 3h hs-cTnT concentration <15 ng/L and a 0/3h-hs-cTnT absolute change <4 ng/L, triaging 138 patients (25%) toward rule-out, resulting in a sensitivity of 99.2% (95% CI, 96.0-99.9), missing 1 patient with NSTEMI. A 0/3h-hs-cTnT absolute change ≥6 ng/L triaged 63 patients (11.2%) toward rule-in, resulting in a specificity of 98% (95% CI, 96.2-98.9) Thereby, the novel 0/3h-criteria reduced the number of patients in the observe zone by 36%s and the number of type 1 myocardial infarction by 50%. Findings were confirmed in both internal and external validation.
A combination of a 3h-hs-cTnT concentration (<15 ng/L) and a 0/3h absolute change (<4 ng/L) is necessary to safely rule out NSTEMI in patients remaining in the observe-zone of the ESC 0/1h-hs-cTnT-algorithm. Registration: URL: https://clinicaltrials.gov; Unique identifier: NCT00470587.
The clinical utility of procalcitonin in the diagnosis and management of pneumonia remains controversial.
We assessed the clinical utility of procalcitonin in 2 prospective studies: first, a ...multicenter diagnostic study in patients presenting to the emergency department with acute dyspnea to directly compare the diagnostic accuracy of procalcitonin with that of interleukin 6 and C-reactive protein (CRP) in the diagnosis of pneumonia; second, a randomized management study of procalcitonin guidance in patients with acute heart failure and suspected pneumonia. Diagnostic accuracy for pneumonia as centrally adjudicated by 2 independent experts was quantified with the area under the ROC curve (AUC).
Among 690 patients in the diagnostic study, 178 (25.8%) had an adjudicated final diagnosis of pneumonia. Procalcitonin, interleukin 6, and CRP were significantly higher in patients with pneumonia than in those without. When compared to procalcitonin (AUC = 0.75; 95% CI, 0.71-0.78), interleukin 6 (AUC = 0.80; 95% CI, 0.77-0.83) and CRP (AUC = 0.82; 95% CI, 0.79-0.85) had significantly higher diagnostic accuracy (
= 0.010 and
< 0.001, respectively). The management study was stopped early owing to the unexpectedly low AUC of procalcitonin in the diagnostic study. Among 45 randomized patients, the number of days on antibiotic therapy and the length of hospital stay were similar (both
= 0.39) in patients randomized to the procalcitonin-guided group (n = 25) and usual-care group (n = 20).
In patients presenting with dyspnea, diagnostic accuracy of procalcitonin for pneumonia is only moderate and lower than that of interleukin 6 and CRP. The clinical utility of procalcitonin was lower than expected.
Pneumonia has diverse and often unspecific symptoms. As the role of biomarkers in the diagnosis of pneumonia remains controversial, it is often difficult to distinguish pneumonia from other illnesses causing shortness of breath. The current study prospectively enrolled unselected patients presenting with acute dyspnea and directly compared the diagnostic accuracy of procalcitonin, interleukin 6, and CRP for the diagnosis of pneumonia. In this setting, diagnostic accuracy of procalcitonin for pneumonia was lower as compared to interleukin 6 and CRP. The clinical utility of procalcitonin was lower than expected.
NCT01831115.
The 2020 guidelines of the European Society of Cardiology (ESC) recommend a novel ESC 0/2h-algorithm as the preferred alternative to the ESC 0/1h-algorithm in the early triage for rule-out and/or ...rule-in of Non-ST-segment-elevation myocardial infarction (NSTEMI). The aim was to prospectively validate the performance of the ESC 0/2h-algorithm using the high-sensitivity cardiac troponin I (hs-cTnI) assay (ARCHITECT) in an international, multicenter diagnostic study enrolling patients presenting with acute chest discomfort to the emergency department.
Patients developing perioperative myocardial infarction/injury (PMI) have a high mortality. PMI work-up and therapy remain poorly defined. This prospective multicenter study included high-risk ...patients undergoing major non-cardiac surgery within a systematic PMI screening and clinical response program. The frequency of cardiovascular imaging during PMI work-up and its yield for possible type 1 myocardial infarction (T1MI) was assessed. Automated PMI detection triggered evaluation by the treating physician/cardiologist, who determined selection/timing of cardiovascular imaging. T1M1 was considered with the presence of a new wall motion abnormality within 30 days in transthoracic echocardiography (TTE), a new scar or ischemia within 90 days in myocardial perfusion imaging (MPI), and Ambrose-Type II or complex lesions within 7 days of PMI in coronary angiography (CA). In patients with PMI, 21% (268/1269) underwent at least one cardiac imaging modality. TTE was used in 13% (163/1269), MPI in 3% (37/1269), and CA in 5% (68/1269). Cardiology consultation was associated with higher use of cardiovascular imaging (27% versus 13%). Signs indicative of T1MI were found in 8% of TTE, 46% of MPI, and 63% of CA. Most patients with PMI did not undergo any cardiovascular imaging within their PMI work-up. If performed, MPI and CA showed high yield for signs indicative of T1MI.Trial registration: https://clinicaltrials.gov/ct2/show/NCT02573532 .