This proof-of-concept study explores the multimodal application of a dedicated cardiac flow phantom for ground truth contrast measurements in dynamic myocardial perfusion imaging with CT, PET/CT, and ...MRI. A 3D-printed cardiac flow phantom and flow circuit mimics the shape of the left ventricular cavity (LVC) and three myocardial regions. The regions are filled with tissue-mimicking materials and the flow circuit regulates and measures contrast flow through LVC and myocardial regions. Normal tissue perfusion and perfusion deficits were simulated. Phantom measurements in PET/CT, CT, and MRI were evaluated with clinically used hardware and software. The reference arterial input flow was 4.0 L/min and myocardial flow 80 mL/min, corresponding to myocardial blood flow (MBF) of 1.6 mL/g/min. The phantom demonstrated successful completion of all processes involved in quantitative, multimodal myocardial perfusion imaging (MPI) applications. Contrast kinetics in time intensity curves were in line with expectations for a mimicked perfusion deficit (38 s vs. 32 s in normal tissue). Derived MBF in PET/CT and CT led to under- and overestimation of reference flow of 0.9 mL/g/min and 4.5 mL/g/min, respectively. Simulated perfusion deficit (0.8 mL/g/min) in CT resulted in MBF of 2.8 mL/g/min. We successfully performed initial, quantitative perfusion measurements with a dedicated phantom setup utilizing clinical hardware and software. These results showcase the multimodal phantom’s potential.
The chemokine receptors CCR2 and CCR5 play important roles in the recruitment of monocytes/macrophages and T cells. To better understand the role of both receptors in murine models of inflammatory ...diseases and to recognize potential problems when correlating these data to humans, we have generated mAbs against murine CCR2 and CCR5. In mice CCR2 is homogeneously expressed on monocytes and on 2--15% of T cells, closely resembling the expression pattern in humans. In contrast to humans, murine NK cells are highly CCR5 positive. In addition, CCR5 is expressed on 3--10% of CD4 and 10--40% of CD8-positive T cells and is weakly detectable on monocytes. Using a model of immune complex nephritis, we examined the effects of inflammation on chemokine receptor expression and found a 10-fold enrichment of CCR5(+) and CCR2(+) T cells in the inflamed kidneys. The activity of various chemokines and the antagonistic properties of the mAbs were measured by ligand-induced internalization of CCR2 and CCR5 on primary leukocytes. The Ab MC-21 (anti-CCR2) reduced the activity of murine monocyte chemotactic protein 1 by 95%, whereas the Ab MC-68 (anti-CCR5) blocked over 99% of the macrophage-inflammatory protein 1alpha and RANTES activity. MC-21 and MC-68 efficiently blocked the ligand binding to CCR2 and CCR5 with an IC(50) of 0.09 and 0.6--1.0 microg/ml, respectively. In good correlation to these in vitro data, MC-21 almost completely prevented the influx of monocytes in thioglycollate-induced peritonitis. Therefore, both Abs appear as useful reagents to further study the role of CCR2 and CCR5 in murine disease models.
Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The ...results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electronic device can be deduced from the simulations.
Strip detectors with an area of
16
cm
2
were processed on high resistivity n-type magnetic Czochralski silicon. In addition, detectors were processed on high resistivity Float Zone wafers with the ...same mask set for comparison. The detectors were irradiated to several different fluences up to the fluence of
3
×
10
15
1
MeV
n
eq
/
cm
2
with protons or with mixed protons and neutrons. The detectors were fully characterized with CV- and IV-measurements prior to and after the irradiation. The beam test was carried out at the CERN H2 beam line using a silicon beam telescope that determines the tracks of the incoming particles and hence provides a reference measurement for the detector characterization. The n-type MCz-Si strip detectors have an acceptable
S/N at least up to the fluence of
1
×
10
15
n
eq
/
cm
2
and thus, they are a feasible option for the strip detector layers in the SLHC tracking systems.
As a result of the high luminosity phase of the SLHC, for CMS a tracking system with very high granularity is mandatory and the sensors will have to withstand an extreme radiation environment of up ...to 10
16
part/
2. On this basis, a new geometry with silicon short strip sensors (strixels) is proposed. To understand their performances, test geometries are developed whose parameters can be verified and optimized using simulation of semiconductor structures. We have used the TCAD-ISE (SYNOPSYS package) software in order to simulate the main electrical parameters of different strip geometries, for p-in-n-type wafers.
A new extensive air shower (EAS) experiment has been installed at the laboratory site of the Forschungszentrum Karlsruhe. The main aim of the KASCADE 1 project is the determination of the chemical ...composition in the energy range around and above the knee of the primary cosmic ray spectrum. The main advantage of the new installation is the simultaneous measurement of a large number of observables for each individual event. This is achieved by the combination of various advanced detection techniques for the electromagnetic, the muonic, and the hadronic component of the extensive air showers. Data taking with a large part of the experiment has started at the end of 1995. The estimated accuracy of air shower data is discussed for the various detector components of KASCADE and first very preliminary results are presented.
Two-dimensional readout of GEM detectors Bressan, A; De Oliveira, R; Gandi, A ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/1999, Letnik:
425, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The recently introduced gas electron multiplier (GEM) permits the amplification of electrons released by ionizing radiation in a gas by factors approaching ten thousand; larger gains can be obtained ...combining two GEMs in cascade. We describe methods for implementing two- and three-dimensional projective localization of radiation, with sub-millimeter accuracy, making use of specially manufactured and patterned pick-up electrodes. Easy to implement and flexible in the choice of the readout geometry, the technology has the distinctive advantage of allowing all pick-up electrodes to be kept at ground potential, thus substantially improving the system simplicity and reliability. Preliminary results demonstrating the two-dimensional imaging capability of the devices are provided and discussed, as well as future perspectives of development.
Status of the silicon strip detector at CMS Simonis, H.J.
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2009, 2009-1-00, Letnik:
598, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The CMS Tracker is the world's largest silicon detector. It has only recently been moved underground and installed in the 4
T solenoid. Prior to this there has been an intensive testing on the ...surface, which confirms that the detector system fully meets the design specifications. Irradiation studies with the sensor material shows that the system will survive for at least 10 years in the harsh radiation environment prevailing within the Tracker volume. The planning phase for SLHC as the successor of LHC, with a 10 times higher luminosity at the same energy has already begun. First R&D studies for more robust detector materials and a new Tracker layout have started.