LArSoft is a set of detector-independent software tools for the simulation, reconstruction and analysis of data from liquid argon (LAr) neutrino experiments The common features of LAr time projection ...chambers (TPCs) enable sharing of algorithm code across detectors of very different size and configuration. LArSoft is currently used in production simulation and reconstruction by the ArgoNeuT, DUNE, LArlAT, MicroBooNE, and SBND experiments. The software suite offers a wide selection of algorithms and utilities, including those for associated photo-detectors and the handling of auxiliary detectors outside the TPCs. Available algorithms cover the full range of simulation and reconstruction, from raw waveforms to high-level reconstructed objects, event topologies and classification. The common code within LArSoft is contributed by adopting experiments, which also provide detector-specific geometry descriptions, and code for the treatment of electronic signals. LArSoft is also a collaboration of experiments, Fermilab and associated software projects which cooperate in setting requirements, priorities, and schedules. In this talk, we outline the general architecture of the software and the interaction with external libraries and detector-specific code. We also describe the dynamics of LArSoft software development between the contributing experiments, the projects supporting the software infrastructure LArSoft relies on, and the core LArSoft support project.
Patients with acute intracerebral hemorrhage (ICH) presenting within 3 hours of symptom onset are known to be at increased risk of expansion. However, only a minority arrive within this time frame. ...Therefore, alternative markers for expansion risk are needed.
To examine whether contrast extravasation on CT angiography (CTA) at presentation predicts subsequent hematoma expansion.
Consecutive patients with primary ICH presenting to an urban tertiary care hospital were prospectively captured in a database. We retrospectively reviewed images for all patients receiving a CTA and at least one further CT scan within 48 hours.
Complete data were available for 104 patients. Contrast extravasation at the time of CTA was present in 56% of patients, and associated with an increased risk of hematoma expansion (22% vs 2%, p = 0.003). Patients who received a baseline CTA within 3 hours were more likely to have subsequent expansion (27%, vs 13% for those presenting later, p = 0.1). However, after multivariable analysis, contrast extravasation was the only significant predictor of hematoma expansion (OR 18, 95% CI 2.1 to 162). This effect was independent of time to presentation.
Contrast extravasation is independently associated with hematoma expansion. Patients presenting within the first few hours after symptom onset have traditionally been considered those at highest risk of expansion. However, for those presenting later, the presence of contrast may be a useful marker to guide therapies aimed at decreasing this risk.
Metal borides have attracted the attention of researchers due to their useful physical properties and unique ability to form high hydrogen-capacity metal borohydrides. We demonstrate improved ...hydrogen storage properties of a nanoscale Mg–B material made by surfactant ball milling MgB2 in a mixture of heptane, oleic acid, and oleylamine. Transmission electron microscopy data show that Mg–B nanoplatelets are produced with sizes ranging from 5 to 50 nm, which agglomerate upon ethanol washing to produce an agglomerated nanoscale Mg–B material of micron-sized particles with some surfactant still remaining. X-ray diffraction measurements reveal a two-component material where 32% of the solid is a strained crystalline solid maintaining the hexagonal structure with the remainder being amorphous. Fourier transform infrared shows that the oleate binds in a “bridge-bonding” fashion preferentially to magnesium rather than boron, which is confirmed by density functional theory calculations. The Mg–B nanoscale material is deficient in boron relative to bulk MgB2 with a Mg–B ratio of ∼1:0.75. The nanoscale MgB0.75 material has a disrupted B–B ring network as indicated by X-ray absorption measurements. Hydrogenation experiments at 700 bar and 280 °C show that it partially hydrogenates at temperatures 100 °C below the threshold for bulk MgB2 hydrogenation. In addition, upon heating to 200 °C, the H–H bond-breaking ability increases ∼10-fold according to hydrogen–deuterium exchange experiments due to desorption of oleate at the surface. This behavior would make the nanoscale Mg–B material useful as an additive where rapid H–H bond breaking is needed.
We report the first measurement of the double-differential and total muon neutrino charged current inclusive cross sections on argon at a mean neutrino energy of 0.8 GeV. Data were collected using ...the MicroBooNE liquid argon time projection chamber located in the Fermilab Booster neutrino beam and correspond to 1.6×1020 protons on target of exposure. The measured differential cross sections are presented as a function of muon momentum, using multiple Coulomb scattering as a momentum measurement technique, and the muon angle with respect to the beam direction. We compare the measured cross sections to multiple neutrino event generators and find better agreement with those containing more complete treatment of quasielastic scattering processes at low Q2. The total flux integrated cross section is measured to be 0.693±0.010(stat)±0.165(syst)×10−38 cm2.
We report on a flux-integrated multi-differential measurement of charged-current muon neutrino scattering on argon with one muon and one proton in the final state using the Booster Neutrino Beam and ...MicroBooNE detector at Fermi National Accelerator Laboratory. The data are studied as a function of various kinematic imbalance variables and of a neutrino energy estimator, and are compared to a number of event generator predictions. We find that the measured cross sections in different phase-space regions are sensitive to nuclear effects. Our results provide precision data to test and improve the neutrino-nucleus interaction models needed to perform high-accuracy oscillation analyses. Specific regions of phase-space are identified where further model refinements are most needed.
We present an analysis of MicroBooNE data with a signature of one muon, no pions, and at least one proton above a momentum threshold of 300 MeV/c (CC0πNp). This is the first differential ...cross-section measurement of this topology in neutrino-argon interactions. We achieve a significantly lower proton momentum threshold than previous carbon and scintillator-based experiments. Using data collected from a total of approximately 1.6×1020 protons on target, we measure the muon neutrino cross section for the CC0πNp interaction channel in argon at MicroBooNE in the Booster Neutrino Beam which has a mean energy of around 800 MeV. We present the results from a data sample with estimated efficiency of 29% and purity of 76% as differential cross sections in five reconstructed variables: the muon momentum and polar angle, the leading proton momentum and polar angle, and the muon-proton opening angle. We include smearing matrices that can be used to “forward fold” theoretical predictions for comparison with these data. We compare the measured differential cross sections to a number of recent theory predictions demonstrating largely good agreement with this first-ever dataset on argon.
We report the first measurement of the flux-integrated cross section of νμ charged-current single π0 production on argon. This measurement is performed with the MicroBooNE detector, an 85 ton active ...mass liquid argon time projection chamber exposed to the Booster Neutrino Beam at Fermilab. This result on argon is compared to past measurements on lighter nuclei to investigate the scaling assumptions used in models of the production and transport of pions in neutrino-nucleus scattering. The techniques used are an important demonstration of the successful reconstruction and analysis of neutrino interactions producing electromagnetic final states using a liquid argon time projection chamber operating at the Earth’s surface.