We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. ...An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated γ -ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV γ-rays. For the inner part of the detector ( R <; 100 mm) , spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1344 ...kg⋅days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7–29 keV, which is compatible with background expectations. This allows the exclusion of the scalar cross-section above 4.8×10−8 pb near 50 GeV/c2 WIMP mass with 90% confidence. Combined with data from the first run, this result improves to 3.9×10−8 pb. The corresponding WIMP-neutron spin-dependent cross-section limit is 8.0×10−3 pb. The ZEPLIN programme reaches thus its conclusion at Boulby, having deployed and exploited successfully three liquid xenon experiments of increasing reach.
We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for ...galactic dark matter weakly interacting massive particles based at the Boulby mine. Analysis of approximately 450 kg x days fiducial exposure allow us to place a 90%-confidence upper limit on the pure WIMP-neutron cross section of sigma(n)=1.9x10(-2) pb at 55 GeV/c(2) WIMP mass. Recent calculations of the nuclear spin structure based on the Bonn charge-dependent nucleon-nucleon potential were used for the odd-neutron isotopes 129Xe and 131Xe. These indicate that the sensitivity of xenon targets to the spin-dependent WIMP-proton interaction could be much lower than implied by previous calculations, whereas the WIMP-neutron sensitivity is impaired only by a factor of approximately 2.
A
bstract
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss appli-cations enabled by the ...excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of ~3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850m water equivalent (w.e.) and a mean muon energy of 260GeV. The measurement ...exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well the measured capture times and multiplicities and, within the dynamic range of the instrumentation, the spectrum of energy deposits. By comparing measurements with simulations of neutron capture rates a neutron yield in lead of (5.78-0.28+0.21) ×10-3neutrons/muon/(g/cm2) has been obtained. Absolute agreement between simulation and data is of order 25%. Consequences for deep underground rare event searches are discussed.
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am–Be neutron sources. The nuclear recoil ...data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ∼40 keVnr is found, together with a rising ionisation yield; both are in agreement with the latest independent measurements. The analysis method is applied to the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am–Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.
We present limits on the WIMP–nucleon cross section for inelastic dark matter from a reanalysis of the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and ...scintillation-to-ionisation ratio, give a net exposure of 63kgday in the range 20–80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under standard halo assumptions a small region of parameter space consistent, at 99% CL, with causing the 1.17tonyr DAMA modulation signal is allowed at 90% CL: it is in the mass range 45–60GeVc−2 with a minimum CL of 87%, again derived from the maximum patch. This is the tightest constraint yet presented using xenon, a target nucleus whose similarity to iodine mitigiates systematic error from the assumed halo.
► We examine backgrounds from radioactivity in the ZEPLIN-III dark matter experiment. ► Electron recoil rates are predicted accurately by Monte Carlo simulation. ► Nuclear recoil rates from neutron ...scattering are also presented. ► We analyse rare background topologies which can affect the sensitivity of direct WIMP searches.
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75±0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level Monte Carlo simulations propagating the effects of the radiological contamination measured for materials employed in the experiment. Neutron elastic scattering is predicted to yield 3.05±0.5 nuclear recoils with energy 5–50keV per year, which translates to an expectation of 0.4 events in a 1yr dataset in anti-coincidence with the veto detector for realistic signal acceptance. Less obvious background sources are discussed, especially in the context of future experiments. These include contamination of scintillation pulses with Cherenkov light from Compton electrons and from β activity internal to photomultipliers, which can increase the size and lower the apparent time constant of the scintillation response. Another challenge is posed by multiple-scatter γ-rays with one or more vertices in regions that yield no ionisation. If the discrimination power achieved in the first run can be replicated, ZEPLIN-III should reach a sensitivity of ∼1×10−8pb·yr to the scalar WIMP–nucleon elastic cross-section, as originally conceived.