We report measurements of oscillation parameters from ν(μ) and ν(μ) disappearance using beam and atmospheric data from MINOS. The data comprise exposures of 10.71×10(20) protons on target in the ...ν(μ)-dominated beam, 3.36×10(20) protons on target in the ν(μ)-enhanced beam, and 37.88 kton yr of atmospheric neutrinos. Assuming identical ν and ν oscillation parameters, we measure |Δm2| = (2.41(-0.10)(+0.09))×10(-3) eV2 and sin2(2θ) = 0.950(-0.036)(+0.035). Allowing independent ν and ν oscillations, we measure antineutrino parameters of |Δm2| = (2.50(-0.25)(+0.23))×10(-3) eV2 and sin2(2θ) = 0.97(-0.08)(+0.03), with minimal change to the neutrino parameters.
The production of protons, anti-protons, neutrons, deuterons and tritons in minimum bias p+C interactions is studied using a sample of 385 734 inelastic events obtained with the NA49 detector at the ...CERN SPS at 158 GeV/c beam momentum. The data cover a phase space area ranging from 0 to 1.9 GeV/c in transverse momentum and in Feynman
x
from −0.8 to 0.95 for protons, from −0.2 to 0.3 for anti-protons and from 0.1 to 0.95 for neutrons. Existing data in the far backward hemisphere are used to extend the coverage for protons and light nuclear fragments into the region of intra-nuclear cascading. The use of corresponding data sets obtained in hadron–proton collisions with the same detector allows for the detailed analysis and model-independent separation of the three principle components of hadronization in p+C interactions, namely projectile fragmentation, target fragmentation of participant nucleons and intra-nuclear cascading.
Successful implementation of the single‐photon‐counting Eiger 500k pixel array detector for sub‐millisecond X‐ray photon correlation spectroscopy (XPCS) measurements in the ultra‐small‐angle ...scattering region is reported. The performance is demonstrated by measuring the dynamics of dilute silica colloids in aqueous solvents when the detector is operated at different counter depths, 4, 8 and 12 bit. In the fastest mode involving 4 bit parallel readout, a stable frame rate of 22 kHz is obtained that enabled measurement of intensity–intensity autocorrelation functions with good statistics down to the 50 µs range for a sample with sufficient scattering power. The high frame rate and spatial resolution together with large number of pixels of the detector facilitate the investigation of sub‐millisecond dynamics over a broad length scale by multispeckle XPCS. This is illustrated by an example involving phoretic motion of colloids during the phase separation of the solvent.
The performance of the high‐resolution fast‐photon‐counting Eiger 500k detector for sub‐millisecond X‐ray photon correlation spectroscopy measurement is demonstrated.