We present a detailed report on sterile neutrino oscillation and 235Uν¯e energy spectrum measurement results from the PROSPECT experiment at the highly enriched High Flux Isotope Reactor (HFIR) at ...Oak Ridge National Laboratory. In 96 calendar days of data taken at an average baseline distance of 7.9 m from the center of the 85 MW HFIR core, the PROSPECT detector has observed more than 50,000 interactions of νe produced in beta decays of 235U fission products. New limits on the oscillation of ν¯e to light sterile neutrinos have been set by comparing the detected energy spectra of ten reactor-detector baselines between 6.7 and 9.2 meters. Measured differences in energy spectra between baselines show no statistically significant indication of ν¯e to sterile neutrino oscillation and disfavor the reactor antineutrino anomaly best-fit point at the 2.5σ confidence level. The reported 235U ν¯e energy spectrum measurement shows excellent agreement with energy spectrum models generated via conversion of the measured 235U beta spectrum, with a χ2/d.o.f. of 31/31. PROSPECT is able to disfavor at 2.4σ confidence level the hypothesis that 235U ν¯e are solely responsible for spectrum discrepancies between model and data obtained at commercial reactor cores. A data-model deviation in PROSPECT similar to that observed by commercial core experiments is preferred with respect to no observed deviation, at a 2.2σ confidence level.
This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of ^{235}U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor ...Oscillation and Spectrum Experiment, consists of a segmented 4 ton ^{6}Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 m water equivalent overburden. Data collected during 33 live days of reactor operation at a nominal power of 85 MW yield a detection of 25 461±283 (stat) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5σ statistical significance within 2 h of on-surface reactor-on data taking. A reactor model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the reactor antineutrino anomaly at 2.2σ confidence level.
Neutral particle detection in high-background environments is greatly aided by the ability to easily load 6Li into liquid scintillators. We describe a readily available and inexpensive liquid ...scintillation cocktail stably loaded with a Li mass fraction up to 1%. Compositions that give thermodynamically stable microemulsions (reverse-micellar systems) were explored, using a Compton spectrum quenching technique to distinguish these from unstable emulsions. Scintillation light yield and transmittance were characterized. Pulse shape discrimination (PSD) was measured using a 252Cf source, showing that electron-like and proton-like recoil events are well-resolved even for Li loading up to 1%, providing a means of background suppression in neutron/neutrino detectors. While samples in this work were prepared with natLi (7.59% 6Li), the neutron capture peak was clearly visible in the PSD spectrum; this implies that while extremely high capture efficiency could be achieved with 6Li-enriched material, a very inexpensive neutron-sensitive detector can be prepared with natLi.
This Letter reports the first measurement of the 235U $\bar{ν}$e energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9 m from the 85 MWth highly ...enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678±304(stat) $\bar{ν}$e-induced inverse beta decays, the largest sample from HEU fission to date, 99% of which are attributed to 235U. Despite broad agreement, comparison of the Huber 235U model to the measured spectrum produces a χ2/ndf=51.4/31, driven primarily by deviations in two localized energy regions. The measured 235U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\bar{ν}$e energy region of 5–7 MeV.
Liquid scintillation cocktails loaded with neutron capture agents such as
6
Li are used in both neutron and neutrino detectors. For detectors designed to operate over extended timespans, long-term ...stability can be a concern. We demonstrate the identification of thermodynamically unstable emulsions as distinct from stable microemulsions, driving phase separation with centrifugation. Phase separation was identified by monitoring the quench indicating parameter, measured using an external Compton source. Samples were also characterized by dynamic light scattering, where in an extreme case, phase separation could be observed in real time. We describe a stable cocktail with 0.01 mass fraction added Li, a relatively high Li concentration.
This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely 235U-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High ...Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. Further, the reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5–7 MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.0 and 3.7 standard deviations the hypotheses that antineutrinos from 235U are solely responsible and noncontributors to the excess observed at commercial reactors, respectively.
Abstract
Background
Continuous evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outpaces monovalent vaccine cross-protection to new viral variants. Consequently, bivalent ...coronavirus disease 2019 (COVID-19) vaccines including Omicron antigens were developed. The contrasting immunogenicity of the bivalent vaccines and the impact of prior antigenic exposure on new immune imprinting remains to be clarified.
Methods
In the large prospective ENFORCE cohort, we quantified spike-specific antibodies to 5 Omicron variants (BA.1 to BA.5) before and after BA.1 or BA.4/5 bivalent booster vaccination to compare Omicron variant-specific antibody inductions. We evaluated the impact of previous infection and characterized the dominant antibody responses.
Results
Prior to the bivalent fourth vaccine, all participants (N = 1697) had high levels of Omicron-specific antibodies. Antibody levels were significantly higher in individuals with a previous polymerase chain reaction positive (PCR+) infection, particularly for BA.2-specific antibodies (geometric mean ratio GMR 6.79, 95% confidence interval CI 6.05–7.62). Antibody levels were further significantly boosted in all individuals by receiving either of the bivalent vaccines, but greater fold inductions to all Omicron variants were observed in individuals with no prior infection. The BA.1 bivalent vaccine generated a dominant response toward BA.1 (adjusted GMR 1.31, 95% CI 1.09–1.57) and BA.3 (1.32, 1.09–1.59) antigens in individuals with no prior infection, whereas the BA.4/5 bivalent vaccine generated a dominant response toward BA.2 (0.87, 0.76–0.98), BA.4 (0.85, 0.75–0.97), and BA.5 (0.87, 0.76–0.99) antigens in individuals with a prior infection.
Conclusions
Vaccination and previous infection leave a clear serological imprint that is focused on the variant-specific antigen. Importantly, both bivalent vaccines induce high levels of Omicron variant-specific antibodies, suggesting broad cross-protection of Omicron variants.
Comparison of antibody responses following bivalent BA.1 and BA.4/5 vaccination and impact of previous infection. Prior antigenic exposure leaves a clear serological imprint. Both bivalent vaccines induce high levels of Omicron variant-specific antibodies, suggesting broad cross-protection of Omicron variants.
Graphical Abstract
Graphical Abstract
https://www.tidbitapp.io/tidbits/omicron-variant-specific-serological-imprinting-following-ba-1-or-ba-4-5-bivalentvaccination-and-previous-sars-cov-2-infection-a-cohort-study/update