Cytotoxic brain edema triggered by neuronal swelling is the chief cause of mortality following brain trauma and cerebral infarct. Using fluorescence lifetime imaging to analyze contributions of ...intracellular ionic changes in brain slices, we find that intense Na(+) entry triggers a secondary increase in intracellular Cl(-) that is required for neuronal swelling and death. Pharmacological and siRNA-mediated knockdown screening identified the ion exchanger SLC26A11 unexpectedly acting as a voltage-gated Cl(-) channel that is activated upon neuronal depolarization to membrane potentials lower than -20 mV. Blockade of SLC26A11 activity attenuates both neuronal swelling and cell death. Therefore cytotoxic neuronal edema occurs when sufficient Na(+) influx and depolarization is followed by Cl(-) entry via SLC26A11. The resultant NaCl accumulation causes subsequent neuronal swelling leading to neuronal death. These findings shed light on unique elements of volume control in excitable cells and lay the ground for the development of specific treatments for brain edema.
Advances in long-read single molecule sequencing have opened new possibilities for 'benchtop' whole-genome sequencing. The Oxford Nanopore Technologies MinION is a portable device that uses nanopore ...technology that can directly sequence DNA molecules. MinION single molecule long sequence reads are well suited for de novo assembly of complex genomes as they facilitate the construction of highly contiguous physical genome maps obviating the need for labor-intensive physical genome mapping. Long sequence reads can also be used to delineate complex chromosomal rearrangements, such as those that occur in tumor cells, that can confound analysis using short reads. Here, we assessed MinION long-read-derived sequences for feasibility concerning: (1) the de novo assembly of a large complex genome, and (2) the elucidation of complex rearrangements. The genomes of two
strains, a wild-type strain and a strain containing two complex rearrangements, were sequenced with MinION. Up to 42-fold coverage was obtained from a single flow cell, and the best pooled data assembly produced a highly contiguous wild-type
genome containing 48 contigs (N50 contig length = 3.99 Mb) covering >99% of the 100,286,401-base reference genome. Further, the MinION-derived genome assembly expanded the
reference genome by >2 Mb due to a more accurate determination of repetitive sequence elements and assembled the complete genomes of two co-extracted bacteria. MinION long-read sequence data also facilitated the elucidation of complex rearrangements in a mutagenized strain. The sequence accuracy of the MinION long-read contigs (∼98%) was improved using Illumina-derived sequence data to polish the final genome assembly to 99.8% nucleotide accuracy when compared to the reference assembly.
We report the sequencing and assembly of a reference genome for the human GM12878 Utah/Ceph cell line using the MinION (Oxford Nanopore Technologies) nanopore sequencer. 91.2 Gb of sequence data, ...representing ∼30× theoretical coverage, were produced. Reference-based alignment enabled detection of large structural variants and epigenetic modifications. De novo assembly of nanopore reads alone yielded a contiguous assembly (NG50 ∼3 Mb). We developed a protocol to generate ultra-long reads (N50 > 100 kb, read lengths up to 882 kb). Incorporating an additional 5× coverage of these ultra-long reads more than doubled the assembly contiguity (NG50 ∼6.4 Mb). The final assembled genome was 2,867 million bases in size, covering 85.8% of the reference. Assembly accuracy, after incorporating complementary short-read sequencing data, exceeded 99.8%. Ultra-long reads enabled assembly and phasing of the 4-Mb major histocompatibility complex (MHC) locus in its entirety, measurement of telomere repeat length, and closure of gaps in the reference human genome assembly GRCh38.
High-throughput complementary DNA sequencing technologies have advanced our understanding of transcriptome complexity and regulation. However, these methods lose information contained in biological ...RNA because the copied reads are often short and modifications are not retained. We address these limitations using a native poly(A) RNA sequencing strategy developed by Oxford Nanopore Technologies. Our study generated 9.9 million aligned sequence reads for the human cell line GM12878, using thirty MinION flow cells at six institutions. These native RNA reads had a median length of 771 bases, and a maximum aligned length of over 21,000 bases. Mitochondrial poly(A) reads provided an internal measure of read-length quality. We combined these long nanopore reads with higher accuracy short-reads and annotated GM12878 promoter regions to identify 33,984 plausible RNA isoforms. We describe strategies for assessing 3' poly(A) tail length, base modifications and transcript haplotypes.
Abstract
Background
Randomized-controlled trials of messenger RNA (mRNA) vaccine protection against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) included relatively few elderly ...participants. We assess single-dose mRNA vaccine effectiveness (VE) in adults ≥ 70 years old in British Columbia, Canada, where second doses were deferred by up to 16 weeks and where a spring 2021 wave uniquely included codominant circulation of Alpha (B.1.1.7) and Gamma (P.1) variants of concern (VOC).
Methods
Analyses included community-dwelling adults ≥ 70 years old with specimen collection between 4 April (epidemiological week 14) and 1 May (week 17) 2021. Adjusted VE was estimated by test-negative design. Cases were reverse-transcription polymerase chain reaction (RT-PCR) test-positive for SARS-CoV-2, and controls were test-negative. Vaccine status was defined by receipt of a single-dose ≥ 21 days before specimen collection, but a range of intervals was assessed. Variant-specific VE was estimated against viruses genetically characterized as Alpha, Gamma or non-VOC lineages.
Results
VE analyses included 16 993 specimens: 1226 (7%) test-positive cases and 15 767 test-negative controls. Of 1131 (92%) genetically characterized viruses, 509 (45%), 314 (28%), and 276 (24%) were Alpha, Gamma, and non-VOC lineages, respectively. At 0–13 days postvaccination, VE was negligible at 14% (95% confidence interval CI, 0–26) but increased from 43% (95% CI, 30–53) at 14–20 days to 75% (95% CI, 63–83) at 35–41 days postvaccination. VE at ≥ 21 days postvaccination was 65% (95% CI, 58–71) overall: 72% (95% CI, 58–81), 67% (95% CI, 57–75), and 61% (95% CI, 45–72) for non-VOC, Alpha, and Gamma variants, respectively.
Conclusions
A single dose of mRNA vaccine reduced the risk of SARS-CoV-2 by about two-thirds in adults ≥ 70 years old, with protection only minimally reduced against Alpha and Gamma variants.
Vaccine effectiveness estimated by test-negative design in British Columbia, Canada, shows one dose of mRNA vaccine reduced the risk of SARS-CoV-2 infection in adults ≥70-years-old by about two-thirds, with protection only minimally reduced against Alpha (B.1.1.7) and Gamma (P.1) variants.
Several severe acute respiratory syndrome coronavirus 2 variants of concern (VOCs) emerged in late 2020; lineage B.1.1.7 initially dominated globally. However, lineages B.1.351 and P.1 represent ...potentially greater risk for transmission and immune escape. In British Columbia, Canada, B.1.1.7 and B.1.351 were first identified in December 2020 and P.1 in February 2021. We combined quantitative PCR and whole-genome sequencing to assess relative contribution of VOCs in nearly 67,000 infections during the first 16 weeks of 2021 in British Columbia. B.1.1.7 accounted for <10% of screened or sequenced specimens early on, increasing to >50% by week 8. P.1 accounted for <10% until week 10, increased rapidly to peak at week 12, and by week 13 codominated within 10% of rates of B.1.1.7. B.1.351 was a minority throughout. This rapid expansion of P.1 but suppression of B.1.351 expands our understanding of population-level VOC patterns and might provide clues to fitness determinants for emerging VOCs.
The Canadian coronavirus disease 2019 (COVID-19) immunization strategy deferred second doses and allowed mixed schedules. We compared 2-dose vaccine effectiveness (VE) by vaccine type (mRNA and/or ...ChAdOx1), interval between doses, and time since second dose in 2 of Canada's larger provinces.
Two-dose VE against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection or hospitalization among adults ≥18 years, including due to Alpha, Gamma, and Delta variants of concern (VOCs), was assessed ≥14 days postvaccination by test-negative design studies separately conducted in British Columbia and Quebec, Canada, between 30 May and 27 November (epi-weeks 22-47) 2021.
In both provinces, all homologous or heterologous mRNA and/or ChAdOx1 2-dose schedules were associated with ≥90% reduction in SARS-CoV-2 hospitalization risk for ≥7 months. With slight decline from a peak of >90%, VE against infection was ≥80% for ≥6 months following homologous mRNA vaccination, lower by ∼10% when both doses were ChAdOx1 but comparably high following heterologous ChAdOx1 + mRNA receipt. Findings were similar by age group, sex, and VOC. VE was significantly higher with longer 7-8-week versus manufacturer-specified 3-4-week intervals between mRNA doses.
Two doses of any mRNA and/or ChAdOx1 combination gave substantial and sustained protection against SARS-CoV-2 hospitalization, spanning Delta-dominant circulation. ChAdOx1 VE against infection was improved by heterologous mRNA series completion. A 7-8-week interval between first and second doses improved mRNA VE and may be the optimal schedule outside periods of intense epidemic surge. Findings support interchangeability and extended intervals between SARS-CoV-2 vaccine doses, with potential global implications for low-coverage areas and, going forward, for children.
The ongoing COVID-19 pandemic necessitates cost-effective, high-throughput, and timely whole-genome sequencing (WGS) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viruses for ...outbreak investigations, identifying variants of concern (VoC), characterizing vaccine breakthrough infections, and public health surveillance. In addition, the enormous demand for WGS on supply chains and the resulting shortages of laboratory supplies necessitated the use of low-reagent and low-consumable methods. Here, we report an optimized library preparation method (the BCCDC cutdown method) that can be used in a high-throughput scenario, where one technologist can perform 576 library preparations (6 plates of 96 samples) over the course of one 8-hour shift. The same protocol can also be used in a rapid turnaround time scenario, from primary samples (up to 96 samples) to loading on a sequencer in an 8-hour shift. This new method uses Freed et al.'s 1,200 bp primer sets (Biol Methods Protoc 5:bpaa014, 2020, https://doi.org/10.1093/biomethods/bpaa014) and a modified and condensed Illumina DNA Prep workflow (Illumina, CA, USA). Compared to the original protocol, the application of this new method using hundreds of clinical specimens demonstrated equivalent results to the full-length DNA Prep workflow at 45% of the cost, 15% of consumables required (such as pipet tips), 25% of manual hands-on time, and 15% of on-instrument time if performing on a liquid handler, with no compromise in sequence quality. Results demonstrate that this new method is a rapid, simple, cost-effective, and high-quality SARS-CoV-2 WGS protocol.
Sequencing has played an invaluable role in the response to the COVID-19 pandemic. Ongoing work in this area, however, demands optimization of laboratory workflow to increase sequencing capacity, improve turnaround time, and reduce cost without compromising sequence quality. This report describes an optimized DNA library preparation method for improved whole-genome sequencing of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pathogen. The workflow advantages summarized here include significant time, cost, and consumable savings, which suggest that this new method is an efficient, scalable, and pragmatic alternative for SARS-CoV-2 whole-genome sequencing.
In British Columbia, Canada, initial growth of the SARS-CoV-2 Delta variant was slower than that reported in other jurisdictions. Delta became the dominant variant (>50% prevalence) within ≈7–13 ...weeks of first detection in regions within the United Kingdom and United States. In British Columbia, it remained at <10% of weekly incident COVID-19 cases for 13 weeks after first detection on March 21, 2021, eventually reaching dominance after 17 weeks. We describe the growth of Delta variant cases in British Columbia during March 1–June 30, 2021, and apply retrospective counterfactual modeling to examine factors for the initially low COVID-19 case rate after Delta introduction, such as vaccination coverage and nonpharmaceutical interventions. Growth of COVID-19 cases in the first 3 months after Delta emergence was likely limited in British Columbia because additional nonpharmaceutical interventions were implemented to reduce levels of contact at the end of March 2021, soon after variant emergence.
The advent of a miniaturized DNA sequencing device with a high-throughput contextual sequencing capability embodies the next generation of large scale sequencing tools. The MinION™ Access Programme ...(MAP) was initiated by Oxford Nanopore Technologies™ in April 2014, giving public access to their USB-attached miniature sequencing device. The MinION Analysis and Reference Consortium (MARC) was formed by a subset of MAP participants, with the aim of evaluating and providing standard protocols and reference data to the community. Envisaged as a multi-phased project, this study provides the global community with the Phase 1 data from MARC, where the reproducibility of the performance of the MinION was evaluated at multiple sites. Five laboratories on two continents generated data using a control strain of Escherichia coli K-12, preparing and sequencing samples according to a revised ONT protocol. Here, we provide the details of the protocol used, along with a preliminary analysis of the characteristics of typical runs including the consistency, rate, volume and quality of data produced. Further analysis of the Phase 1 data presented here, and additional experiments in Phase 2 of E. coli from MARC are already underway to identify ways to improve and enhance MinION performance.