High levels of laser power stability are necessary for high precision metrology applications. The classical limit for the achievable power stability is determined by the shot noise of the light used ...to generate a power control signal. Increasing the power of the detected light reduces the relative shot noise level and allows higher stabilities. However, sufficiently high power is not always available and the detection of high laser powers is challenging. Here, we demonstrate a nonclassical way to improve the achievable power stability without increasing the detected power. By the injection of a squeezed vacuum field of light we improve the classical laser power stability beyond its shot noise limit by 9.4_{-0.6}^{+0.6} dB at Fourier frequencies between 5 and 80 kHz. For only 90.6 μA of detected photocurrent we achieve a relative laser power noise of 2.0_{-0.1}^{+0.1}×10^{-8}/sqrtHz. This is the first demonstration of a squeezed light-enhanced laser power stabilization and its performance is equivalent to an almost tenfold increase of detected laser power in a classical scheme. The analysis reveals that the technique presented here has the potential to achieve stability levels of 4.2×10^{-10}/sqrtHz with 58 mA photocurrent measured on a single photodetector.
The nature of dark matter remains unknown to date, although several candidate particles are being considered in a dynamically changing research landscape
. Scalar field dark matter is a prominent ...option that is being explored with precision instruments, such as atomic clocks and optical cavities
. Here we describe a direct search for scalar field dark matter using a gravitational-wave detector, which operates beyond the quantum shot-noise limit. We set new upper limits on the coupling constants of scalar field dark matter as a function of its mass, by excluding the presence of signals that would be produced through the direct coupling of this dark matter to the beam splitter of the GEO600 interferometer. These constraints improve on bounds from previous direct searches by more than six orders of magnitude and are, in some cases, more stringent than limits obtained in tests of the equivalence principle by up to four orders of magnitude. Our work demonstrates that scalar field dark matter can be investigated or constrained with direct searches using gravitational-wave detectors and highlights the potential of quantum-enhanced interferometry for dark matter detection.
Photon shot noise, arising from the quantum-mechanical nature of the light, currently limits the sensitivity of all the gravitational wave observatories at frequencies above one kilohertz. We report ...a successful application of squeezed vacuum states of light at the GEO 600 observatory and demonstrate for the first time a reduction of quantum noise up to 6.03±0.02 dB in a kilometer scale interferometer. This is equivalent at high frequencies to increasing the laser power circulating in the interferometer by a factor of 4. Achieving this milestone, a key goal for the upgrades of the advanced detectors required a better understanding of the noise sources and losses and implementation of robust control schemes to mitigate their contributions. In particular, we address the optical losses from beam propagation, phase noise from the squeezing ellipse, and backscattered light from the squeezed light source. The expertise gained from this work carried out at GEO 600 provides insight toward the implementation of 10 dB of squeezing envisioned for third-generation gravitational wave detectors.
Only a few years ago, it was realized that the zero-area Sagnac interferometer topology is able to perform quantum nondemolition measurements of position changes of a mechanical oscillator. Here, we ...experimentally show that such an interferometer can also be efficiently enhanced by squeezed light. We achieved a nonclassical sensitivity improvement of up to 8.2 dB, limited by optical loss inside our interferometer. Measurements performed directly on our squeezed-light laser output revealed squeezing of 12.7 dB. We show that the sensitivity of a squeezed-light enhanced Sagnac interferometer can surpass the standard quantum limit for a broad spectrum of signal frequencies without the need for filter cavities as required for Michelson interferometers. The Sagnac topology is therefore a powerful option for future gravitational-wave detectors, such as the Einstein Telescope, whose design is currently being studied.
From 1 April 2019 to 27 March 2020, the Advanced Virgo detector, together with the two Advanced LIGO detectors, conducted the third joint scientific observation run O3, aiming for further detections ...of gravitational wave signals from astrophysical sources. One of the upgrades to the Virgo detector for O3 was the implementation of the squeezed light technology to improve the detector sensitivity beyond its classical quantum shot noise limit. In this paper, we present a detailed description of the optical setup and performance of the employed squeezed light source. The squeezer was constructed as an independent, stand-alone sub-system operated in air. The generated squeezed states are tailored to exhibit high purity at intermediate squeezing levels in order to significantly reduce the interferometer shot noise level while keeping the correlated enhancement of quantum radiation pressure noise just below the actual remaining technical noise in the Advanced Virgo detector.
Squeezed states of light belong to the most prominent nonclassical resources. They have compelling applications in metrology, which has been demonstrated by their routine exploitation for improving ...the sensitivity of a gravitational-wave detector since 2010. Here, we report on the direct measurement of 15 dB squeezed vacuum states of light and their application to calibrate the quantum efficiency of photoelectric detection. The object of calibration is a customized InGaAs positive intrinsic negative (p-i-n) photodiode optimized for high external quantum efficiency. The calibration yields a value of 99.5% with a 0.5% (k=2) uncertainty for a photon flux of the order 10^{17} s^{-1} at a wavelength of 1064 nm. The calibration neither requires any standard nor knowledge of the incident light power and thus represents a valuable application of squeezed states of light in quantum metrology.
We report on the experimental combination of three advanced interferometer techniques for gravitational wave detection, namely, power recycling, detuned signal recycling, and squeezed field ...injection. For the first time, we experimentally prove the compatibility of especially the latter two. To achieve a broadband nonclassical sensitivity improvement, we applied a filter cavity for compensation of quadrature rotation. The signal-to-noise ratio was improved by up to 2.8 dB beyond the coherent state's shot noise. The complete setup was stably locked for arbitrary times and characterized by injected single-sideband modulation fields.
Mirror thermal noise will be a main limitation for the sensitivities of the next-generation ground-based gravitational-wave detectors (Einstein Telescope and Cosmic Explorer) at signal frequencies ...around 100 Hz. Using a higher-order spatial laser mode instead of the fundamental mode is one proposed method to further mitigate mirror thermal noise. In the current detectors, quantum noise is successfully reduced by the injection of squeezed vacuum states. The operation in a higher-order mode would then require the efficient generation of squeezed vacuum states in this mode to maintain a high quantum noise reduction. In our setup, we generate continuous-wave squeezed states at a wavelength of 1064 nm in the fundamental and three higher-order Hermite-Gaussian modes up to a mode order of 6 using a type-I optical parametric amplifier. We present a significant milestone with a quantum noise reduction of up to 10 dB at a measurement frequency of 4 MHz in the higher-order modes and pave the way for their usage in future gravitational-wave detectors as well as in other quantum noise limited experiments.