Current risk stratification for sudden cardiac death (SCD) in nonischemic dilated cardiomyopathy (NIDC) relies on left ventricular (LV) dysfunction, a poor marker of ventricular electrical ...instability. Contrast-enhanced cardiac magnetic resonance has the ability to accurately identify and quantify ventricular myocardial fibrosis (late gadolinium enhancement LGE).
To evaluate the impact of the presence and amount of myocardial fibrosis on arrhythmogenic risk prediction in NIDC.
One hundred thirty-seven consecutive patients with angiographically proven NIDC were enrolled for this study. All patients were followed up for a combined arrhythmic end point including sustained ventricular tachycardia (VT), appropriate implantable cardioverter-defibrillator (ICD) intervention, ventricular fibrillation (VF), and SCD.
LV-LGE was identified in 76 (55.5%) patients. During a median follow-up of 3 years, the combined arrhythmic end point occurred in 22 (16.1%) patients: 8 (5.8%) sustained VT, 9 (6.6%) appropriate ICD intervention, either against VF (n = 5; 3.6%) or VT (n = 4; 2.9%), 3 (2.2%) aborted SCD, and 2 (1.5%) died suddenly. Kaplan-Meier analysis revealed a significant correlation between the LV-LGE presence (not the amount and distribution) and malignant arrhythmic events (P < .001). In univariate Cox regression analysis, LV-LGE (hazard ratio HR 4.17; 95% confidence interval CI 1.56-11.2; P = .005) and left bundle branch block (HR 2.43; 95% CI 1.01-5.41; P = .048) were found to be associated with arrhythmias. In multivariable analysis, the presence of LGE was the only independent predictor of arrhythmias (HR 3.8; 95% CI 1.3-10.4; P = .01).
LV-LGE is a powerful and independent predictor of malignant arrhythmic prognosis, while its amount and distribution do not provide additional prognostic value. Contrast-enhanced cardiac magnetic resonance may contribute to identify candidates for ICD therapy not fulfilling the current criteria based on left ventricular ejection fraction.
Arrhythmogenic Cardiomyopathy (ACM) is characterized by the replacement of the myocardium with fibrotic or fibro-fatty tissue and inflammatory infiltrates in the heart. To date, while ACM ...adipogenesis is a well-investigated differentiation program, ACM-related fibrosis remains a scientific gap of knowledge. In this study, we analyze the fibrotic process occurring during ACM pathogenesis focusing on the role of cardiac mesenchymal stromal cells (C-MSC) as a source of myofibroblasts. We performed the ex vivo studies on plasma and right ventricular endomyocardial bioptic samples collected from ACM patients and healthy control donors (HC). In vitro studies were performed on C-MSC isolated from endomyocardial biopsies of both groups. Our results revealed that circulating TGF-β1 levels are significantly higher in the ACM cohort than in HC. Accordingly, fibrotic markers are increased in ACM patient-derived cardiac biopsies compared to HC ones. This difference is not evident in isolated C-MSC. Nevertheless, ACM C-MSC are more responsive than HC ones to TGF-β1 treatment, in terms of pro-fibrotic differentiation and higher activation of the SMAD2/3 signaling pathway. These results provide the novel evidence that C-MSC are a source of myofibroblasts and participate in ACM fibrotic remodeling, being highly responsive to ACM-characteristic excess TGF-β1.
Diagnosis of Arrhythmogenic CardioMyopathy (ACM) is challenging and often late after disease onset. No circulating biomarkers are available to date. Given their involvement in several cardiovascular ...diseases, plasma microRNAs warranted investigation as potential non-invasive diagnostic tools in ACM. We sought to identify circulating microRNAs differentially expressed in ACM with respect to Healthy Controls (HC) and Idiopathic Ventricular Tachycardia patients (IVT), often in differential diagnosis. ACM and HC subjects were screened for plasmatic expression of 377 microRNAs and validation was performed in 36 ACM, 53 HC, 21 IVT. Variable importance in data partition was estimated through Random Forest analysis and accuracy by Receiver Operating Curves. Plasmatic miR-320a showed 0.53 ± 0.04 fold expression difference in ACM vs. HC (p < 0.01). A similar trend was observed when comparing ACM (n = 13) and HC (n = 17) with athletic lifestyle, a ACM precipitating factor. Importantly, ACM patients miR-320a showed 0.78 ± 0.05 fold expression change vs. IVT (p = 0.03). When compared to non-invasive ACM diagnostic parameters, miR-320a ranked highly in discriminating ACM vs. IVT and it increased their accuracy. Finally, miR-320a expression did not correlate with ACM severity. Our data suggest that miR-320a may be considered a novel potential biomarker of ACM, specifically useful in ACM vs. IVT differentiation.
Sudden cardiac death in athletes is a relatively rare event, but due to the increasing number of individuals practicing high-performance sports, in absolute terms, it has become an important issue to ...be addressed. Since etiologies are many and the occurrence is rare, tracing the ideal preparticipation screening program is challenging. So far, as screening tools, a comprehensive clinical evaluation and a simple 12-lead electrocardiogram (ECG) seem to be the most cost-effective strategy. Recent technological advances came to significantly help as second-line investigation tools, especially the cardiac magnetic resonance, which allows for a more detailed ventricular evaluation, cardiac tissue characterization, and eliminates the poor acoustic window problem. This article aims to review all aspects related to sudden cardiac death in athletes, beginning with definitions and epidemiology, passing through etiology and clinical characteristics, then finishing with a discussion about the best ambulatory investigational approach.
Autologous vein and artery remains the first choice for vascular grafting procedures in small-diameter vessels such as coronary and lower limb districts. Unfortunately, these vessels are often found ...to be unsuitable in atherosclerotic patients due to the presence of calcifications or to insufficient size. Synthetic grafts composed of materials such as expanded polytetrafluoroethylene (ePTFE) are frequently employed as second choice, because of their widespread availability and success in the reconstruction of larger arteries. However, ePTFE grafts with small diameter are plagued by poor patency rates due to surface thrombogenicity and intimal hyperplasia, caused by the bioinertness of the synthetic material and aggravated by low flow conditions. Several bioresorbable and biodegradable polymers have been developed and tested to exploit such issues for their potential stimulation to endothelialization and cell infiltration. Among these, silk fibroin (SF) has shown promising pre-clinical results as material for small-diameter vascular grafts (SDVGs) because of its favorable mechanical and biological properties. A putative advantage in graft infection in comparison with synthetic materials is plausible, although it remains to be demonstrated. Our literature review will focus on the performance of SF-SDVGs
, as evaluated by studies performing vascular anastomosis and interposition procedures, within small and large animal models and different arterial districts. Efficiency under conditions that more accurately mime the human body will provide encouraging evidence towards future clinical applications.
Cardiac magnetic resonance (CMR) findings suggesting a suspected left-dominant arrhythmogenic cardiomyopathy (LDAC) may be difficult to distinguish from those related to previous myocarditis; ...however, especially in patients with ventricular arrhythmias (VA) with ECG morphology consistent with a left ventricle (LV) origin differential diagnosis is fundamental. Aim of the study was to identify potential imaging features at CMR specific for LDAC diagnosis. Between January 2011 and December 2019, we enrolled 15 consecutive stable patients with a recent diagnosis of significant VA and ECG morphology consistent with a LV origin, detection of potential LV arrhythmic substrate at CMR and undergoing a clinically-indicated LV endomyocardial biopsy showing tissue abnormalities consistent with the diagnosis of LDAC. From the same CMR-endomyocardial biopsy registry, a second group of 30 consecutive patients who underwent CMR and biopsy with a histological diagnosis of previous myocarditis were identified. (1) Subepicardial LGE at the level of the posterolateral wall of the LV was detected in 13 cases of LDAC vs. 21 cases of myocarditis; (2) fat infiltration, and particularly subepicardial posterolateral fat infiltration, was found in almost all LDAC patients vs. one myocarditis only (p < 0.01). (3) No differences in other CMR findings or in any clinical or echocardiographic parameters were found between patients with a biopsy consistent with LDAC vs. myocarditis. In patients with significant VA and ECG morphology consistent with a LV origin, the presence of morpho-functional involvement of the subepicardial layer of LV posterolateral wall at CMR (LGE, fat infiltration, wall dyskinesis) supports LDAC diagnosis.
Background
Only a few studies have systematically evaluated fluoroscopy data of electrophysiological and device implantation procedures. Aims of this study were to quantify ionizing radiation ...exposure for electrophysiological/device implantation procedures in a large series of patients and to analyze the x‐ray exposure trend over years and radiation exposure in patients undergoing atrial fibrillation ablation considering different technical aspects.
Methods and Results
We performed a retrospective analysis of all electrophysiological/device implantation procedures performed during the past 7 years in a modern, large‐volume laboratory. We reported complete fluoroscopy data on 8150 electrophysiological/device implantation procedures (6095 electrophysiological and 2055 device implantation procedures); for each type of procedure, effective dose and lifetime attributable risk of cancer incidence and mortality were calculated. Over the 7‐year period, we observed a significant trend reduction in fluoroscopy time, dose area product, and effective dose for all electrophysiological procedures (P<0.001) and a not statistically significant trend reduction for device implantation procedures. Analyzing 2416 atrial fibrillation ablations, we observed a significant variability of fluoroscopy time, dose area product and effective dose among 7 different experienced operators (P<0.0001) and a significant reduction of fluoroscopy use over time (P<0.0001) for all of them. Considering atrial fibrillation ablation techniques, fluoroscopy time was not different (P = 0.74) for radiofrequency catheter ablation in comparison with cryoablation, though cryoablation was still associated with higher dose area product and effective dose values (P<0.001).
Conclusions
Electrophysiological procedures involve a nonnegligible x‐ray use, leading to an increased risk of malignancy. Awareness of radiation‐related risk, together with technological advances, can successfully optimize fluoroscopy use.
Eosinophilic granulomatosis with polyangiitis (EGPA) is a rare multisystem disorder; cardiac involvement may include eosinophilic myocarditis. A 67‐year‐old woman presented with 1‐week history of ...dyspnoea and orthopnoea. She had a history of adult‐onset asthma and peripheral eosinophilia. The investigations showed T‐wave inversion on lateral leads, peripheral eosinophilia, elevated troponin and BNP values, and severe biventricular systolic dysfunction with diffuse hypokinesia and apical akinesia. Computed tomography excluded coronary disease and showed bilateral basal ground‐glass opacities, air‐space consolidation, and bilateral reticular‐nodular pattern. Cardiac magnetic resonance findings were compatible with active myocardial inflammation. An endomyocardial biopsy (EMB) confirmed the diagnosis of eosinophilic myocarditis, and a therapy with oral corticosteroids and heart failure medications was started.
Based on a plenty of different applications, intracardiac echocardiography (ICE) is now a well-established technology in complex electrophysiological procedures. Recently, ICE has become the most ...widely used ultrasound-based imaging tool to guide diagnostic endomyocardial biopsy (EMB). EMB of cardiac mass guided by ICE is an interesting application of ICE. Allowing a correct positioning of the bioptome, ICE reduce the procedure-related risks and the need of a diagnostic open-chest procedure reserving the more invasive approach to selected cases.
Hereby we report a case series of right ventricular masses in which the EMB was safely and effectively performed under ICE guidance giving essential information for planning the therapeutic strategy.
The diagnosis of both metastatic and primary cardiac tumors relies on the histopathological analyses. The endomyocardial biopsy is a valuable tool for preoperative diagnosis and surgical planning of intracardiac masses suspected for tumors. In our experience, the use of ICE for right ventricle EMB of an intracardiac mass is an attractive modality thanks to the precise localization of the cardiac structures and the ability to guide bioptic withdrawal in the target area.
Clinical evaluation of syncope in the athlete remains a challenge. Although benign mechanisms predominate, syncope may be arrhythmic and precede SCD. Exercise-induced syncope should be regarded as an ...important alarming symptom of an underlying cardiac disease predisposing to arrhythmic cardiac arrest. All athletes with syncope require a focused and detailed workup for underlying cardiac causes, either structural or electrical. Major aim is to identify athletes at risk and to protect them from SCD. Athletes with potentially life-threatening etiologies of syncope should be restricted from competitive sports.