Abstract Background The optimal management of patients found to have multivessel disease while undergoing primary percutaneous coronary intervention (P-PCI) for ST-segment elevation myocardial ...infarction is uncertain. Objectives CvLPRIT (Complete versus Lesion-only Primary PCI trial) is a U.K. open-label randomized study comparing complete revascularization at index admission with treatment of the infarct-related artery (IRA) only. Methods After they provided verbal assent and underwent coronary angiography, 296 patients in 7 U.K. centers were randomized through an interactive voice-response program to either in-hospital complete revascularization (n = 150) or IRA-only revascularization (n = 146). Complete revascularization was performed either at the time of P-PCI or before hospital discharge. Randomization was stratified by infarct location (anterior/nonanterior) and symptom onset (≤3 h or >3 h). The primary endpoint was a composite of all-cause death, recurrent myocardial infarction (MI), heart failure, and ischemia-driven revascularization within 12 months. Results Patient groups were well matched for baseline clinical characteristics. The primary endpoint occurred in 10.0% of the complete revascularization group versus 21.2% in the IRA-only revascularization group (hazard ratio: 0.45; 95% confidence interval: 0.24 to 0.84; p = 0.009). A trend toward benefit was seen early after complete revascularization (p = 0.055 at 30 days). Although there was no significant reduction in death or MI, a nonsignificant reduction in all primary endpoint components was seen. There was no reduction in ischemic burden on myocardial perfusion scintigraphy or in the safety endpoints of major bleeding, contrast-induced nephropathy, or stroke between the groups. Conclusions In patients presenting for P-PCI with multivessel disease, index admission complete revascularization significantly lowered the rate of the composite primary endpoint at 12 months compared with treating only the IRA. In such patients, inpatient total revascularization may be considered, but larger clinical trials are required to confirm this result and specifically address whether this strategy is associated with improved survival. (Complete Versus Lesion-only Primary PCI Pilot Study CvLPRIT; ISRCTN70913605 )
The extension of the cosmic-ray spectrum beyond 1 petaelectronvolt (PeV; 10
electronvolts) indicates the existence of the so-called PeVatrons-cosmic-ray factories that accelerate particles to PeV ...energies. We need to locate and identify such objects to find the origin of Galactic cosmic rays
. The principal signature of both electron and proton PeVatrons is ultrahigh-energy (exceeding 100 TeV) γ radiation. Evidence of the presence of a proton PeVatron has been found in the Galactic Centre, according to the detection of a hard-spectrum radiation extending to 0.04 PeV (ref.
). Although γ-rays with energies slightly higher than 0.1 PeV have been reported from a few objects in the Galactic plane
, unbiased identification and in-depth exploration of PeVatrons requires detection of γ-rays with energies well above 0.1 PeV. Here we report the detection of more than 530 photons at energies above 100 teraelectronvolts and up to 1.4 PeV from 12 ultrahigh-energy γ-ray sources with a statistical significance greater than seven standard deviations. Despite having several potential counterparts in their proximity, including pulsar wind nebulae, supernova remnants and star-forming regions, the PeVatrons responsible for the ultrahigh-energy γ-rays have not yet been firmly localized and identified (except for the Crab Nebula), leaving open the origin of these extreme accelerators.
We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China ...Jinping Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8×10^{-42} and 3×10^{-36} cm^{2} at a 90% confidence level on spin-independent and spin-dependent WIMP-nucleon cross sections, respectively, at a WIMP mass (m_{χ}) of 5 GeV/c^{2} are achieved. The lower reach of m_{χ} is extended to 2 GeV/c^{2}.
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass p-type point-contact germanium detector of the CDEX-1B ...experiment at the China Jinping Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2-yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus (χ-N) spin-independent cross sections as function of WIMP mass (m_{χ}) at 90% confidence level (C.L.) are derived using the dark matter halo model. Within the context of the standard halo model, the 90% C.L. allowed regions implied by the DAMA/LIBRA and CoGeNT AM-based analysis are excluded at >99.99% and 98% C.L., respectively. These results correspond to the best sensitivity at m_{χ}<6 GeV/c^{2} among WIMP AM measurements to date.
We reveal the cooperative effect of coherent and dissipative magnon-photon couplings in an open cavity magnonic system, which leads to nonreciprocity with a considerably large isolation ratio and ...flexible controllability. Furthermore, we discover unidirectional invisibility for microwave propagation, which appears at the zero-damping condition for hybrid magnon-photon modes. A simple model is developed to capture the generic physics of the interference between coherent and dissipative couplings, which accurately reproduces the observations over a broad range of parameters. This general scheme could inspire methods to achieve nonreciprocity in other systems.
The manipulation of quantum states of light
holds the potential to enhance searches for fundamental physics. Only recently has the maturation of quantum squeezing technology coincided with the ...emergence of fundamental physics searches that are limited by quantum uncertainty
. In particular, the quantum chromodynamics axion provides a possible solution to two of the greatest outstanding problems in fundamental physics: the strong-CP (charge-parity) problem of quantum chromodynamics
and the unknown nature of dark matter
. In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. Few dark matter searches have approached this limit
, and until now none has exceeded it. Here we use vacuum squeezing to circumvent the quantum limit in a search for dark matter. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature
, we double the search rate for axions over a mass range favoured by some recent theoretical projections
. We find no evidence of dark matter within the axion rest energy windows of 16.96-17.12 and 17.14-17.28 microelectronvolts. Breaking through the quantum limit invites an era of fundamental physics searches in which noise reduction techniques yield unbounded benefit compared with the diminishing returns of approaching the quantum limit.
By engineering an anti-parity-time (anti-PT ) symmetric cavity magnonics system with precise eigenspace controllability, we observe two different singularities in the same system. One type of ...singularity, the exceptional point (EP), is produced by tuning the magnon damping. Between two EPs, the maximal coherent superposition of photon and magnon states is robustly sustained by the preserved anti-PT symmetry. The other type of singularity, arising from the dissipative coupling of two antiresonances, is an unconventional bound state in the continuum (BIC). At the settings of BICs, the coupled system exhibits infinite discontinuities in the group delay. We find that both singularities coexist at the equator of the Bloch sphere, which reveals a unique hybrid state that simultaneously exhibits the maximal coherent superposition and slow light capability.
The caliber of the retinal vessels has been shown to be associated with stroke events. However, the consistency and magnitude of association, and the changes in predicted risk independent of ...traditional risk factors, are unclear. To determine the association between retinal vessel caliber and the risk of stroke events, the investigators combined individual data from 20,798 people, who were free of stroke at baseline, in 6 cohort studies identified from a search of the Medline (National Library of Medicine, Bethesda, Maryland) and EMBASE (Elsevier B.V., Amsterdam, the Netherlands) databases. During follow-up of 5–12 years, 945 (4.5%) incident stroke events were recorded. Wider retinal venular caliber predicted stroke (pooled hazard ratio = 1.15, 95% confidence interval: 1.05, 1.25 per 20-μm increase in caliber), but the caliber of retinal arterioles was not associated with stroke (pooled hazard ratio = 1.00, 95% confidence interval: 0.92, 1.08). There was weak evidence of heterogeneity in the hazard ratio for retinal venular caliber, which may be attributable to differences in follow-up strategies across studies. Inclusion of retinal venular caliber in prediction models containing traditional stroke risk factors reassigned 10.1% of people at intermediate risk into different, mostly lower, risk categories.
Two pairs of positive-and negative-parity doublet bands together with eight strong electric dipole transitions linking their yrast positive- and negative-parity bands have been identified in ^{78}Br. ...They are interpreted as multiple chiral doublet bands with octupole correlations, which is supported by the microscopic multidimensionally-constrained covariant density functional theory and triaxial particle rotor model calculations. This observation reports the first example of chiral geometry in octupole soft nuclei.