Abstract
Aims
The benefit of prophylactic implantable cardioverter-defibrillator (ICD) is not uniform due to differences in the risk of life-threatening ventricular tachycardia (VT)/ventricular ...fibrillation (VF) and non-arrhythmic mortality. We aimed to develop an ICD benefit prediction score that integrates the competing risks.
Methods and results
The study population comprised all 4531 patients enrolled in the MADIT trials. Best-subsets Fine and Gray regression analysis was used to develop prognostic models for VT (≥200 b.p.m.)/VF vs. non-arrhythmic mortality (defined as death without prior sustained VT/VF). Eight predictors of VT/VF (male, age < 75 years, prior non-sustained VT, heart rate > 75 b.p.m., systolic blood pressure < 140 mmHg, ejection fraction ≤ 25%, myocardial infarction, and atrialarrhythmia) and 7 predictors of non-arrhythmic mortality (age ≥ 75 years, diabetes mellitus, body mass index < 23 kg/m2, ejection fraction ≤ 25%, New York Heart Association ≥II, ICD vs. cardiac resynchronization therapy with defibrillator, and atrial arrhythmia) were identified. The two scores were combined to create three MADIT-ICD benefit groups. In the highest benefit group, the 3-year predicted risk of VT/VF was three-fold higher than the risk of non-arrhythmic mortality (20% vs. 7%, P < 0.001). In the intermediate benefit group, the difference in the corresponding predicted risks was attenuated (15% vs. 9%, P < 0.01). In the lowest benefit group, the 3-year predicted risk of VT/VF was similar to the risk of non-arrhythmic mortality (11% vs. 12%, P = 0.41). A personalized ICD benefit score was developed based on the distribution of the two competing risks scores in the study population (https://is.gd/madit). Internal and external validation confirmed model stability.
Conclusions
We propose the novel MADIT-ICD benefit score that predicts the likelihood of prophylactic ICD benefit through personalized assessment of the risk of VT/VF weighed against the risk of non-arrhythmic mortality.
Graphical Abstract
Long QT syndrome (LQTS) is the first described and most common inherited arrhythmia. Over the last 25 years, multiple genes have been reported to cause this condition and are routinely tested in ...patients. Because of dramatic changes in our understanding of human genetic variation, reappraisal of reported genetic causes for LQTS is required.
Utilizing an evidence-based framework, 3 gene curation teams blinded to each other's work scored the level of evidence for 17 genes reported to cause LQTS. A Clinical Domain Channelopathy Working Group provided a final classification of these genes for causation of LQTS after assessment of the evidence scored by the independent curation teams.
Of 17 genes reported as being causative for LQTS, 9 (
) were classified as having limited or disputed evidence as LQTS-causative genes. Only 3 genes (
) were curated as definitive genes for typical LQTS. Another 4 genes (
) were found to have strong or definitive evidence for causality in LQTS with atypical features, including neonatal atrioventricular block. The remaining gene (
) had moderate level evidence for causing LQTS.
More than half of the genes reported as causing LQTS have limited or disputed evidence to support their disease causation. Genetic variants in these genes should not be used for clinical decision-making, unless accompanied by new and sufficient genetic evidence. The findings of insufficient evidence to support gene-disease associations may extend to other disciplines of medicine and warrants a contemporary evidence-based evaluation for previously reported disease-causing genes to ensure their appropriate use in precision medicine.
Objectives The present study was designed to explore the 8-year survival benefit of a nonresynchronization implantable cardioverter-defibrillator (ICD) according to a simple risk stratification ...score. Background There is limited information regarding factors that predict the benefit of primary prevention with an ICD during long-term follow-up. Methods This study used a previously developed risk score including 5 clinical factors (New York Heart Association functional class >II, age >70 years, blood urea nitrogen >26 mg/dl, QRS duration >0.12 s, and atrial fibrillation) to evaluate 8-year ICD survival benefit within risk score categories among 1,191 MADIT-II (Multicenter Automatic Defibrillator Implantation Trial II) patients. Results Patients with low (0 risk factors, n = 345) and intermediate risk (1 to 2 risk factors, n = 646) demonstrated a significantly higher probability of survival at 8-year follow-up when treated by ICD as compared with non-ICD therapy (75% vs. 58%, p = 0.004; and 47% vs. 31%, p < 0.001, respectively). By contrast, among high-risk patients (3 or more risk factors, n = 200), there was no significant difference in 8-year survival between the ICD and non-ICD subgroups (19% vs. 17%, p = 0.50). Consistently, multivariate analysis showed that ICD therapy was associated with a significant long-term survival benefit among low- and intermediate-risk patients (hazard ratio HR: 0.52, p < 0.001, and HR: 0.66, p < 0.001, respectively), whereas treatment with an ICD was not associated with a significant benefit among high-risk patients (HR: 0.84, p = 0.25). Conclusions These findings suggest that a simple risk score can identify patients who derive significant long-term benefit from primary ICD therapy. High-risk patients with multiple comorbidities composed 17% of the MADIT-II population and did not derive long-term benefit from nonresynchronization device therapy.
The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential ...adverse effects.
We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective was to determine whether programmed high-rate therapy (with a 2.5-second delay before the initiation of therapy at a heart rate of ≥200 beats per minute) or delayed therapy (with a 60-second delay at 170 to 199 beats per minute, a 12-second delay at 200 to 249 beats per minute, and a 2.5-second delay at ≥250 beats per minute) was associated with a decrease in the number of patients with a first occurrence of inappropriate antitachycardia pacing or shocks, as compared with conventional programming (with a 2.5-second delay at 170 to 199 beats per minute and a 1.0-second delay at ≥200 beats per minute).
During an average follow-up of 1.4 years, high-rate therapy and delayed ICD therapy, as compared with conventional device programming, were associated with reductions in a first occurrence of inappropriate therapy (hazard ratio with high-rate therapy vs. conventional therapy, 0.21; 95% confidence interval CI, 0.13 to 0.34; P<0.001; hazard ratio with delayed therapy vs. conventional therapy, 0.24; 95% CI, 0.15 to 0.40; P<0.001) and reductions in all-cause mortality (hazard ratio with high-rate therapy vs. conventional therapy, 0.45; 95% CI, 0.24 to 0.85; P=0.01; hazard ratio with delayed therapy vs. conventional therapy, 0.56; 95% CI, 0.30 to 1.02; P=0.06). There were no significant differences in procedure-related adverse events among the three treatment groups.
Programming of ICD therapies for tachyarrhythmias of 200 beats per minute or higher or with a prolonged delay in therapy at 170 beats per minute or higher, as compared with conventional programming, was associated with reductions in inappropriate therapy and all-cause mortality during long-term follow-up. (Funded by Boston Scientific; MADIT-RIT ClinicalTrials.gov number, NCT00947310.).
Abstract Brugada syndrome is an inherited heart disease without structural abnormalities that is thought to arise as a result of accelerated inactivation of Na channels and predominance of transient ...outward K current ( Ito ) to generate a voltage gradient in the right ventricular layers. This gradient triggers ventricular tachycardia/ventricular fibrillation possibly through a phase 2 reentrant mechanism. The Brugada electrocardiographic (ECG) pattern, which can be dynamic and is sometimes concealed, being only recorded in upper precordial leads, is the hallmark of Brugada syndrome. Because of limitations of previous consensus documents describing the Brugada ECG pattern, especially in relation to the differences between types 2 and 3, a new consensus report to establish a set of new ECG criteria with higher accuracy has been considered necessary. In the new ECG criteria, only 2 ECG patterns are considered: pattern 1 identical to classic type 1 of other consensus (coved pattern) and pattern 2 that joins patterns 2 and 3 of previous consensus (saddle-back pattern). This consensus document describes the most important characteristics of 2 patterns and also the key points of differential diagnosis with different conditions that lead to Brugada-like pattern in the right precordial leads, especially right bundle-branch block, athletes, pectus excavatum, and arrhythmogenic right ventricular dysplasia/cardiomyopathy. Also discussed is the concept of Brugada phenocopies that are ECG patterns characteristic of Brugada pattern that may appear and disappear in relation with multiple causes but are not related with Brugada syndrome.
This study aimed to determine whether QRS morphology identifies patients who benefit from cardiac resynchronization therapy with a defibrillator (CRT-D) and whether it influences the risk of primary ...and secondary end points in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial.
Baseline 12-lead ECGs were evaluated with regard to QRS morphology. Heart failure event or death was the primary end point of the trial. Death, heart failure event, ventricular tachycardia, and ventricular fibrillation were secondary end points. Among 1817 patients with available sinus rhythm ECGs at baseline, there were 1281 (70%) with left bundle-branch block (LBBB), 228 (13%) with right bundle-branch block, and 308 (17%) with nonspecific intraventricular conduction disturbances. The latter 2 groups were defined as non-LBBB groups. Hazard ratios for the primary end point for comparisons of CRT-D patients versus patients who only received an implantable cardioverter defibrillator (ICD) were significantly (P < 0.001) lower in LBBB patients (0.47; P < 0.001) than in non-LBBB patients (1.24; P = 0.257). The risk of ventricular tachycardia, ventricular fibrillation, or death was decreased significantly in CRT-D patients with LBBB but not in non-LBBB patients. Echocardiographic parameters showed significantly (P < 0.001) greater reduction in left ventricular volumes and increase in ejection fraction with CRT-D in LBBB than in non-LBBB patients.
Heart failure patients with New York Heart Association class I or II and ejection fraction ≤ 30% and LBBB derive substantial clinical benefit from CRT-D: a reduction in heart failure progression and a reduction in the risk of ventricular tachyarrhythmias. No clinical benefit was observed in patients with a non-LBBB QRS pattern (right bundle-branch block or intraventricular conduction disturbances).
URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.
Objectives We aimed to evaluate the relationship between echocardiographic response to cardiac resynchronization therapy (CRT) and the risk of subsequent ventricular tachyarrhythmias (VTAs). ...Background Current data regarding the effect of CRT on the risk of VTA are limited and conflicting. Methods The risk of a first appropriate implantable cardioverter-defibrillator (ICD) therapy for VTA (including ventricular tachycardia, ventricular fibrillation, and ventricular flutter) was compared between high- and low-echocardiographic responders to CRT defibrillator (CRT-D) therapy (defined as ≥25% and <25% reductions, respectively, in left ventricular end-systolic volume LVESV at 1 year compared with baseline) and ICD-only patients enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy). Results The cumulative probability of a first VTA at 2 years after assessment of echocardiographic response was highest among low responders to CRT-D (28%), intermediate among ICD-only patients (21%), and lowest among high responders to CRT-D (12%), with p < 0.001 for the overall difference during follow-up. Multivariate analysis showed that high responders to CRT-D experienced a significant 55% reduction in the risk of VTA compared with ICD-only patients (p < 0.001), whereas the risk of VTA was not significantly different between low responders and ICD-only patients (hazard ratio HR: 1.26; p = 0.21). Consistently, assessment of response to CRT-D as a continuous measure showed that incremental 10% reductions in left ventricular end-systolic volume were associated with corresponding reductions in the risk of subsequent VTA (HR: 0.80; p < 0.001), VTA/death (HR: 0.79; p < 0.001), ventricular tachycardia (HR: 0.80; p < 0.001), and ventricular fibrillation/ventricular flutter (HR: 0.75; p = 0.044). Conclusions In patients with left ventricular dysfunction enrolled in the MADIT-CRT trial, reverse remodeling was associated with a significant reduction in the risk of subsequent life-threatening VTAs. (Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy MADIT-CRT; NCT00180271 )